Up/Down Counting Pulse Indicator K3HB-C CSM K3HB-C DS E 17 3 Measure High-speed Up/down Pulses with this Up/down Pulse Meter. Visual conf0rmation of judgement results through display colors that switch between red and green. *1 Perfect for Measuring Rotary Encoder and ON/OFF Pulse Signals at High Speed Cumulative pulse input is 50 kHz, quadrature pulse inputs are 25 kHz, and up/ down pulse inputs are 30 kHz. Note: No-voltage contacts of up to 30 Hz are supported. The count value can be converted to any value. The length equivalent for any pulse can be set to any desired value. This is effective for feed amount and position monitor displays. DeviceNet models added to the series. *2 *1 Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet. You can change the display color by setting it, but you cannot switch it based on the judgement results. *2 DeviceNet models have a depth of 97 mm. For the most recent information on models that have been certified for Refer to Safety Precautions for All Digital Panel safety standards, refer to your OMRON website. Meters. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-C - K3HB-C 1234 5 15 2. Sensor Power Supply/Output Type Code 1. Input Sensor Code NB: NPN input/voltage pulse input None: None 5. Supply Voltage CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC10%, 80 mA) (See note 1.) 100-240 VAC:100 to 240 VAC L1A: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply 24 VAC/VDC: 24 VAC/VDC (12 VDC10%, 80 mA) (See note 2.) L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply Optional Board (12 VDC10%, 80 mA) (See note 2.) A: Sensor power supply (12 VDC 10%, 80 mA) Sensor Power Supply/Output Boards FLK1A: Communications (RS-232C) + Sensor power supply (12 VDC10%, 80 mA) (See note 2.) K33- FLK3A: Communications (RS-485) + Sensor power supply 2 (12 VDC10%, 80 mA) (See note 2.) Note: 1. CPA can be combined with relay outputs only. Relay/Transistor Output Boards 2. Only one of the following can be used by each Digital Indicator: RS-232C/ RS-485 communications, a linear output, or DeviceNet communications. K34- 3. Relay/Transistor Output Type Code 3 None: None C2: Relay contact (HH/H/LL/L: SPST-NO each) Event Input Boards T1: Transistor (NPN open collector: HH/H/PASS/L/LL) T2: Transistor (PNP open collector: HH/H/PASS/L/LL) K35- BCD :BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL) 4 DRT: DeviceNet (See note 2.) A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code None: None 1: 5 inputs (M3 terminal block), NPN open collector 2 : 8 inputs (10-pin MIL connector), NPN open collector 3: 5 inputs (M3 terminal block), PNP open collector 4 : 8 inputs (10-pin MIL connector), PNP open collector There is no bank selection forNon andDeviceNe types ofTransistor Output Type Cod. Note: The following combinations are not possible. Communications (FLK A) + DeviceNet (DRT) Communications (FLK A) + BCD output (BCD) Linear current/voltage (L A) + DeviceNet (DRT) 1K3HB-C Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model Y92A-49N K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings Supply voltage 100 to 240 VAC, 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC range Power consumption 100 to 240 VAC: 18 VA max. (max. load) (See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) No-voltage contact, voltage pulse, open collector Input External power supply 12 VDC10% 80 mA Event inputs Hold input NPN open collector or no-voltage contact signal ON residual voltage: 2 V max. Reset input ON current at 0 : 4 mA max. Bank input Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. Output ratings Relay output 250 VAC, 30 VDC, 5 A (resistive load) (depends on Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations the model) Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V no output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green)) Main functions Scaling function, measurement operation selection, output hysteresis, output OFF delay, output test, and power in- terruption memory (See note 2.), display value selection, display color selection, key protection, bank selection, dis- play refresh period, maximum/minimum hold, reset Ambient operating temperature 10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature 25 to 65C (with no icing or condensation) Altitude 2,000 m max. Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a De- Accessories viceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. The five displayed digits are stored in memory. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 2