90W Single Output External Power 90W Single Output External Power ME90 Family ME90 Family Medical Series Medical Series FEATURES AND BENEFITS Meets UL/EN/IEC60601-1-2, 4th edition for Desktop Style Package Medical EMC* Meets EN55011/CISPR11, FCC Part 15.109 Approved to EN/IEC/UL60601-1, 3rd edition Class B conducted & radiated emissions, with isolation levels which satisfy the 2 MOPP with 6db margin requirements E-cap life of >7 years Meets DoE efficiency level VI requirements No load input power 3 years warranty Average efficiency IP22 rated enclosure Up to 90W of AC-DC power Note: * Professional equipment only. Consult factory for Table 9 compliance information. MODEL SELECTION Output Output Output Line Load Overvoltage 1 Model Number Volts Ripple & Noise Connector Current Power Regulation Regulation Trip Level ME90A1251F01 12.0V 7.50A 90W 120mV pk-pk 1% 5% 2 6 pin Molex Type Class I Desktop, ME90A1503F01 15.0V 6.00A 90W 150mV pk-pk 1% 5% IEC60320 C14 2.5 x 5.5 x 9.5mm ME90A1803F01 18.0V 5.00A 90W 180mV pk-pk 1% 5% Receptacle Straight Barrel Type, ME90A2403F01 24.0V 3.75A 90W 240mV pk-pk 1% 5% center positive ME90A1251N01 12.0V 7.50A 90W 120mV pk-pk 1% 5% 2 6 pin Molex Type Class II Desktop, ME90A1503N01 15.0V 6.00A 90W 150mV pk-pk 1% 5% IEC60320 C8 2.5 x 5.5 x 9.5mm ME90A1803N01 18.0V 5.00A 90W 180mV pk-pk 1% 5% Receptacle Straight Barrel Type, center positive ME90A2403N01 24.0V 3.75A 90W 240mV pk-pk 1% 5% ME90A1251Q01 12.0V 7.50A 90W 120mV pk-pk 1% 5% 2 6 pin Molex Type Class II Desktop, ME90A1503Q01 15.0V 6.00A 90W 150mV pk-pk 1% 5% IEC60320 C18 2.5 x 5.5 x 9.5mm ME90A1803Q01 18.0V 5.00A 90W 180mV pk-pk 1% 5% Receptacle Straight Barrel Type, center positive ME90A2403Q01 24.0V 3.75A 90W 240mV pk-pk 1% 5% 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. Notes : 2. Molex p/n 39-01-2060 or equivalent. See outline drawing for pinout information. 3. For Input Class I models: For AC GND connected to output common (-), insert a B in the part number where the A is located (ME90B1251F01). INPUT AC Input 100-240Vac, 10%, 47-63Hz, 1 Input Current 115Vac: 2.0A, 230Vac: 1.0A Inrush Current 264Vac, cold start: will not exceed 60A Input Fuses F1, F2: 3.15A, 250Vac fuses (line & neutral lines) provided on all models <500A 264Vac, 60Hz, NC Earth Leakage Current (Input to Ground) <1mA 264Vac, 60Hz, SFC Efficiency >88%, typical No Load Input Power <0.210W (meets DoE efficiency level VI requirements) ME90 Family Datasheet v1121 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 1 ME90 Family Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.90W Single Output External Power 90W Single Output External Power 90W Single Output External Power ME90 Family ME90 Family ME90 Family Medical Series Medical Series Medical Series OUTPUT Hold-Up Time 20mS min., at full Load, 100Vac input Turn On Time Less than 1 sec 115Vac, full load <100A 264Vac, 60Hz, NC Patient Leakage Current (Output to Earth) <500A 264Vac, 60Hz, SFC Output Power 90W continuous - See models chart for specific voltage model ratings Output Voltage See models chart on pg 1 Ripple and Noise See models chart on pg 1 500s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to Transient Response 100% of rated load, i/t< 0.2A/s. Max. voltage deviation is +/-3.5% Regulation See models chart on pg 1 PROTECTION SAFETY Will shutdown upon an overtemperature condition, Safety Standards EN/IEC/UL60601-1, 3rd edition Overtemperature auto-recovery Protection Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total 130 to 180% of rating, Hiccup Mode Overload Protection Non-Operating: Half-sine waveform, impact Shock Short Circuit acceleration of 100G, Pulse duration of 6mS, Hiccup Mode, auto recovery Protection Number of shocks: 3 for each of the three axis Overvoltage 130 to 150% of output voltage, hiccup mode Protection Drop Test 1.4m from table top to wooden platform, 4 faces RELIABILITY >2,50,000 hours, Full load, 110 & 220Vac input, MTBF 25C amb, per Telcordia 332 Issue 6 ISOLATION SPECIFICATION >7 year life based on calculations at 115Vac/60Hz Input - Output: 2 MOPP & 230Vac/50Hz, ambient 25C at 24 hrs per day, E-Cap Life Isolation Input - Ground: 1 MOPP 365 days/year, 6 power up cycles per day. Output - Ground: 1 MOPP (80% load on 5V, 12V models) ENVIRONMENT -20C to +50C. Derate above 40C Operating Temperature Start Up at -40C, full load, (warmup period before all parameters are within published specifications) Storage Temperature -40C to +85C Operating: to 5000m. Altitude Non-operating: -500 to 40,000 ft Relative Humidity 5% to 95%, non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: Vibration 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes W: 2.58 x L: 5.9 x H: 1.34 Dimensions W: 65.5mm x L: 150.5Mm x H: 34mm Weight 600g ME90 Family Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. ME90 Family Datasheet v1121 Copyright 20 21 SL Power Electronics Corp. All rights reserved. Page 2 ME90 Family Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved.