Power Transformers TRANSF ISO 250W

Manufacturer: Tripp Lite
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

4: USD 217.1862 ea
Line Total: USD 868.74

0 - Global Stock
MOQ: 4  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Mon. 20 May to Fri. 24 May

MOQ : 1
Multiples : 1

Stock Image

IS250HG
Tripp Lite

1 : USD 305.9674
3 : USD 279.0434
5 : USD 265.0952

0 - WHS 2


Ships to you between Mon. 20 May to Fri. 24 May

MOQ : 4
Multiples : 1

Stock Image

IS250HG
Tripp Lite

4 : USD 217.1862

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Power Rating
Primary Voltage Rating
Length
Width
Height
Termination Style
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
N001-003-BL electronic component of Tripp Lite N001-003-BL

Ethernet Cables / Networking Cables 3 Cat5e/Cat5 350MHz RJ45 M/M Blue 3
Stock : 173

N001-005-BK electronic component of Tripp Lite N001-005-BK

NETWORK CABLE, RJ45, CAT5E, 5FT, BLK
Stock : 10

MR1612 electronic component of Tripp Lite MR1612

UNIVERSAL MONITOR RISER, 1.25-5.5"; Acce; UNIVERSAL MONITOR RISER, 1.25-5.5"; Accessory Type:Universal Monitor Riser; Load Capacity:18kg; Product Range:-
Stock : 7

Image Description
IS-250 electronic component of Intashield IS-250

Power Transformers Isolation Transformer 250W Surge 120V 2 Outlet 6ft Cord TAA GSA
Stock : 0

IS-1000 electronic component of Tripp Lite IS-1000

Power Transformers Tripp Lite Isolation Transformer 1000W Surge 120V 4 Outlet 6ft Cord TAA GSA
Stock : 0

298CT electronic component of Hammond 298CT

Power Transformers Plug-In/StepUp 250VA 120-240VAC, 2 Outlet
Stock : 1

298ET electronic component of Hammond 298ET

Power Transformers Plug-In/StepUp 750VA 120-240VAC, 2 Outlet
Stock : 3

229E24 electronic component of Hammond 229E24

Power Transformers LOW PROFILE
Stock : 0

229E230 electronic component of Hammond 229E230

Power Transformers LOW PROFILE
Stock : 6

229E12 electronic component of Hammond 229E12

Power Transformers 12.6 CT@200/6.3V@400
Stock : 4

Hot 229D30 electronic component of Hammond 229D30

Power Transformers LOW PROFILE
Stock : 20

229D24 electronic component of Hammond 229D24

Power Transformers LOW PROFILE
Stock : 1

229D12 electronic component of Hammond 229D12

Power Transformers LOW PROFILE
Stock : 3

Highlights Isolator Series 120V 250W UL60601-1 Medical-Grade Complete line isolation, noise Isolation Transformer with 2 Hospital-Grade Outlets filtering and surge suppression ideal for sensitive equipment MODEL NUMBER: IS250HG 250 watts, 2 outlets, 6-ft. power cord Hospital-grade plug and receptacles Leakage current less than 100 microamps Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases Package Includes IS250HG Isolation Transformer Instruction manual with warranty information Description Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 NEMA5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade Output - 2 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle) Features The IS250HG Medical Grade Isolation Transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles ideal for the protection of sensitive electronic equipment in patient-care areas. Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps Secondary neutral-to-ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops Additional surge suppression components placed at the line input and output combined with full line isolation provide continuous filtering of a full range of power line noise in all modes Active transformer filtering offers continuous common-mode noise rejection with no wearable parts unique ability to reduce surges in the worst of power 1 / 3 Active transformer filtering offers continuous common-mode noise rejection with no wearable parts unique ability to reduce surges in the worst of power environments to harmless levels Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode Includes 2 widely spaced NEMA 5-15R hospital-grade output receptacles, a 6-ft. power cord, hospital-grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower placement in any industrial, medical, office or network environment Specifications OVERVIEW Efficiency 96% Let-through Voltage (Combination L-N: 250V L-G: 250V N-G: 0.5V Wave) Let-through Voltage (Ring Wave) L-N: 20V L-G: 20V N-G: 0.5V Nominal Voltage / Frequency 120V/60Hz Over Current Protection 2A circuit breaker Shipping Weight 13.80 lbs. / 6.26 kg Suppression Joule Rating 940 joules Surge Test Conditions Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms Total Harmonic Distortion Less than 1% VA / Watt Capacity 250 Transformer Type Medical grade, low impedance transformer-based line isolation transformer OUTPUT Output Receptacles (2) 5-15R-HG Ouput Amp Capacity 2.1 INPUT Input Cord Length (ft.) 6 Input Cord Length (m) 1.83 Input Plug Type NEMA 5-15P-HG SURGE / NOISE SUPPRESSION Noise Suppression Rating 35-65 DB ISOLATION Leakage Current Less than 100 microamps 2 / 3

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
Tripp Lite
Tripp-Lite
Waber By Tripp Lite

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted