Product Information

IS-250

IS-250 electronic component of Intashield

Datasheet
Power Transformers Isolation Transformer 250W Surge 120V 2 Outlet 6ft Cord TAA GSA

Manufacturer: Intashield
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 55.9516 ea
Line Total: USD 55.95

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 26 Apr to Thu. 02 May

MOQ : 1
Multiples : 1

Stock Image

IS-250
Intashield

1 : USD 55.9516
5 : USD 54.2203

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Packaging
Brand
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
Image Description
Hot PH9185.034NLT electronic component of Pulse PH9185.034NLT

Pulse Transformers Audio & Signal TRANSFORMER 750UH 3:4 SMD
Stock : 300

F-211Z electronic component of Triad F-211Z

Power Transformers POWER XFMR 48.0Vct@0.250A 115/230V CHASSIS MOUNT w/LUGS
Stock : 18

F3-56 electronic component of Triad F3-56

Power Transformers 2.4VA 56VCT at .045A QUICK CONNECT
Stock : 1

161GA12 electronic component of Hammond 161GA12

Power Transformers LOW VOLTAGE RECT
Stock : 9

FP16-375 electronic component of Triad FP16-375

Power Transformers POWER XFMR 16.0Vct@0.375A UL/cUL FLAT PACK PCB MOUNT/FP16-375
Stock : 41

FP230-10 electronic component of Triad FP230-10

Power Transformers POWER XFMR 230.0Vct@0.010A UL/cUL FLAT PACK PCB MOUNT/FP230-10
Stock : 25

F12-1600 electronic component of Triad F12-1600

Power Transformers POWER XFMR 12.6Vct@1.6A UL/cUL 115V SPLIT PACK PCB MOUNT/F12-1600
Stock : 9

F56-020 electronic component of Triad F56-020

Power Transformers 1.1VA 56V CT @ 0.02A Split Pack
Stock : 1

VPL36-140 electronic component of Triad VPL36-140

Power Transformers POWER XFMR 36Vct@0.14A UL/cUL/TUV CHASSIS MOUNT
Stock : 0

VPL26-190 electronic component of Triad VPL26-190

Power Transformers POWER XFMR 26.8Vct@0.19A UL/cUL/TUV CHASSIS MOUNT
Stock : 3

Highlights Isolator Series 120V 250W Isolation Complete line isolation, noise Transformer-Based Power Conditioner, 2 Outlets filtering and surge suppression is ideal for sensitive equipment MODEL NUMBER: IS250 250 watts, 2 outlets, 6-ft. power cord Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases Package Includes IS250 Isolation transformer system Instruction manual with warranty information Description Tripp Lite Isolator series isolation transformer-based power conditioners offer complete line isolation, continuous noise filtering and enhanced normal and common mode surge suppression. Internal low-impedance isolation transformer component with Faraday Shield offers 100% isolation from the input AC line. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, background spikes generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at both the line input and transformer output combined with full line isolation offers continuous line filtering of a full range of power line noise in all modes. Continuous transformer filtering with no wearable parts uniquely reduces surges in the worst of power environments to harmless levels. Reduces 6000V IEEE C62.41 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250 offers 250 watts capacity with 2 widely spaced output receptacles, a 6-ft power cord, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in industrial, medical, office or network environment. PLUG/OUTLETS: Input: NEMA 5-15P/Output: 2 NEMA5-15R ELECTRICAL: 120V AC, 60Hz, 2.1A, (Requires NEMA5-15R wall receptacle) FORMAT: Upright tower with keyhole flanges for wall mount placement ISOLATION: Transformer based line isolation with Faraday shield Features Tripp Lite Isolator series isolation transformer-based power conditioners offer complete line isolation, continuous noise filtering and enhanced common mode surge suppression Supports combined loads up to 250 watts continuous/2.1A at 120V Isolation transformer with Faraday Shield offers 100% isolation from the input AC line Neutral to ground bonding at the secondary eliminates common mode noise and provides an isolated ground reference for sensitive equipment Isolation transformer design serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades Removes EMI/RFI noise, utility switching transients, background spikes and power problems generated by other on-site loads, utility grid-switching and 1 / 3 lightning related surges Line isolation with additional surge suppression components offer continuous line filtering of a full range of power line noise in all modes Continuous transformer filtering with no wearable parts reduces surges in the worst of power environments to harmless levels Includes 2 widely-spaced NEMA5-15R output receptacles, 6 ft power cord, circuit breaker overload protection and lighted power switch Rugged all-metal housing ships ready for upright tower or wallmount installation Specifications OVERVIEW Efficiency 96% Let-through Voltage (Combination L-N: <130V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. B Wave) Let-through Voltage (Ring Wave) L-N: <10V L-G: <10V N-G: <0.5V IEEE C62.41 Cat. A Nominal Voltage / Frequency 120V / 60Hz Over Current Protection Yes, 2A circuit breaker Suppression Joule Rating 680 Surge Test Conditions Per ANSI/IEEE C62.41 - (IEEE587) Cat. A & B test waveforms Total Harmonic Distortion less than 1% VA / Watt Capacity 250 Transformer Type Low impedence isolation transformer OUTPUT Output Receptacles (2) 5-15R Output Amp Capacity 2.1 INPUT Input Circuit Breakers One 3A thermal breaker Maximum Input Amps 2.2 Input Cord Length (ft.) 6 Input Cord Length (m) 1.83 Input Plug Type NEMA 5-15P SURGE / NOISE SUPPRESSION Noise Suppression Rating 33-65dB normal mode >80dB common mode PHYSICAL Shipping Dimensions (hwd / in.) 7.1 x 7.1 x 10.0 Shipping Dimensions (hwd / cm) 18 x 18 x 25.4 2 / 3

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted