Product Information

HPL110

HPL110 electronic component of Unipower

Datasheet
DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P

Manufacturer: Unipower
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 826.7498 ea
Line Total: USD 826.75

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

HPL110
Unipower

1 : USD 826.7498

     
Manufacturer
Product Category
Supply Voltage Min
Supply Voltage Max
No Of Phases
Power Rating
Output Voltage Max
Product Range
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
PCU D10 electronic component of Unipower PCU D10

CONTROL/DISPLAY UNIT, APM110E, 15-30V
Stock : 0

HPL500 electronic component of Unipower HPL500

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

HPL110A electronic component of Unipower HPL110A

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

HPL110 electronic component of Unipower HPL110

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

APM382 electronic component of Unipower APM382

ANALOGUE MOTOR LOAD MONITOR, 24V
Stock : 0

APM110E electronic component of Unipower APM110E

ANALOGUE MOTOR LOAD MONITOR, 230V
Stock : 0

APM112E electronic component of Unipower APM112E

MOTOR LOAD MONITOR, 230V
Stock : 0

DSU D382 electronic component of Unipower DSU D382

DISPLAY/PGMMING UNIT, APM382, 15-30V
Stock : 0

Image Description
560-8414-02 electronic component of Concord 560-8414-02

560841402 concord
Stock : 0

LP2S-26S-889-Z electronic component of Nidec Copal LP2S-26S-889-Z

SWITCH PUSHBUTTON DPDT 3A 125V
Stock : 0

050-043-0000220 electronic component of ITT 050-043-0000220

RF/COAXIAL, SMC JACK, STRAIGHT, 50 OHM, SOLDER
Stock : 240

ALC74HC138D,653 electronic component of NXP ALC74HC138D,653

Decoder/Demultiplexer Single 3-to-8 16-Pin SO T/R
Stock : 0

560-8418-02 electronic component of Concord 560-8418-02

560841802 concord
Stock : 0

HP-L-0500-203-3%-RH electronic component of Spectra Symbol HP-L-0500-203-3%-RH

Resistive Sensor Linear Position Flexible Membrane - Linear Connector
Stock : 0

LP2S-27S-209-Z electronic component of Nidec Copal LP2S-27S-209-Z

SWITCH PUSHBUTTON DPDT 3A 125V
Stock : 0

LP2S-27S-229-Z electronic component of Nidec Copal LP2S-27S-229-Z

SWITCH PUSHBUTTON DPDT 3A 125V
Stock : 0

560-8804-02 electronic component of Concord 560-8804-02

560880402 concord
Stock : 0

ALC74LV595PW,118 electronic component of Nexperia ALC74LV595PW,118

Shift Register Single 8-Bit Serial to Serial/Parallel 16-Pin TSSOP T/R
Stock : 15000

Display & Programming overview. HPL110 Unipower Version 4.0 Technical Information English Edition Technical Specifications Electrical Voltage Range The HPL110 is programmed by the use of only three keys located at the front panel. See See Technical info on the unit paragraph about programming on page 2. The parameters and their programming ranges are Also availible: listed in the table above. Parameters are stored in EEPROM. When no key has been activated for 3 x 120 VAC -> 3 x 575 VAC about 5 seconds the display returns to the kW % position. Note that the function of the keys is Current Range repeated if continuously activated. Internal: max. 8 Amp. External: N/1 or N/5 converter. Cos Range::::: 0-1 LED usage: Frequency Range: 45-65 Hz. The HPL110 has a number of LEDs , which Consumption. are used to indicated to the user the condition Supply = measuring voltage, 2 VA. of the unit, i.e. above trip points or alarms. The table below shows the usage of the LEDs. Mechanical Housing Makrolon 8020 (30% GV), UL94V-1 (house). Makrolon 2800, UL94V-2 (connector + front). Mounting Snap-on construction for 35mm DIN T H E C O N C E P T rail mounting or panel mounting. The Unipower HPL110 is a low-cost Protection Class member of a family of Intelligent Power- IP40 (house). Control Units. The unit measures true IP20 (connector). power-consumtption and shows the o Temperature Range: -15 - +50 C consumption as a percentage of the Weight: Approx. 400g. selected power-range. The power- Note An external current converter (if present) must always be mounted in Dimensions: D110 x W56 x H75 mm. consumption (kW) is calculated from the the L3-phase for correct measurement. The polarity is not important. CE-mark to: following formula: EN61000-6-2, EN61000-6-3, EN61010-1 P = 3 x U x I x Cos UL certified: The primary function of the HPL110 lies in UL 508 - Industrial Control Equipment the supervision and control of machinery driven by 3-phased AC-motors. The HPL110 integrates a Max. and/or a Min. kW limit detector plus the support functions necessary to establish the efficient and compact supervision or regulation of various types of machinery such as pumps, ventilators and conveyer belts. The HPL110 has a built in current converter that works up to 8 Amp. Page 4 Page 1Generally. 7 and 8 and choose the 1A or 5A currrent range, Theoretically: The power measurement principle is based depending on the converter (N/1 or N/5). The Md = P2 x 60 / 2n, where upon integration of the power in every period measurement range in kW = 3 x U x I, where U Md: Torque where alarm should be given. (20 ms at 50Hz). Therefore the HPL110 also is the nominal voltage and I is the choosen P2: Corresponding shaft power. measures true power consumption on non sine current range or nominal primary current of the n: Revolutions in rev/min. shaped loads such as frequency inverters. external current converter. Ex. 1A and 400V gi- P1 = P2 + Po (Or from the efficiency curve of the ves a measurement range of 0.692 kW motor). Programming: corresponding to 100%. Limit % = 100 x P1/P, where Figur 2 The HPL110 is programmed by the use of only P: Measurement range of the HPL110. three keys located on the front panel. The Functions The limits can be deactivated by setting the Min Mode key is used to select one of the seven limit to 0 and the Max limit to 101%. When a Hysteresis: programmable parameters. When a parameter The figure below shows a typical AC-motor limit is deactivated Off is written on the dis- The figure to the left shows how possible Max is chosen the value may be altered by the use power consumption curve (ex. pump) play. and Min hysteresis bands are placed relatively of the arrow keys. immediately after power has been applied to Peak detectors: to the limits. The hysteresis band always lies the motor. At the bottom of the figure a bar is Leave the motor running at normal load and above a Min limit and below a Max limit. Hys- Measurement ranges: shown indicating the position of the relay (On/ read the peak values by activating the arrow teresis is activated when an alarm is generated The HPL110 has a built-in current converter Off). keys in kW % - mode. Place the Max limit and the external reset is active (Input S1, Auto that works up to 8A. One of four internal current appropriately above the Max peak value and reset mode). If Auto reset is chosen and both ranges may be chosen: 1, 3, 5 or 8A. If the unit Choosing limits: the Min limit appropriately below the min peak limits are active, only the Max hysteresis band measures on loads where the current exceeds Deciding the limits can be done in two ways: value. The peak detectors may be reset is active, because the HPL110 only has one 8A an external current converter must be Theoretically or using the peak detectors in the seperately by pressing the relevant arrow key relay. connected. This is done by connecting the HPL110. and at the same time activate the Reset key. secondary side of the converter to pin Ts: Start timer Input S2: Blocking of alarms The programmable start timer (Ts) is used to Like Ts blocks for alarms during start of the avoid alarms at motor start. The Ts delay function motor, alarms can be ignored by setting S2 to is activated after the power consumption Gnd. reaches 5%. When Ts expires the limits, hys- Ex 1: If a brief overload is expected, a PLC teresis and Tr become active. If the power output or the like may be used to block for a consumption drops below 5%, the supervision short period of time. is switched off again. Ex 2: If the Min. kW limit is used, a spare break Tr: Reaction timer switch from the Motor Switch must be connected The figure shows how the reaction timer (Tr) is between the S2 input and Gnd, otherwise an activated after the limit is exceeded. Tr is used alarm is generated each time the motor is to avoid alarms, unless the limit has been switched off on purpose. exceeded for a certain time. If Tr is set to 0, Tr equals the measurement interval of 20ms DIP switch: (16.7ms at 60Hz). The DIP switch is placed under the front plate Resetting alarms: (see figure 3). Alarms may be reset by the reset key on the SW1-No programming: The parameters may be front panel or by Input S1. read but not altered, when Sw 1 is On. SW2: If this switch is on, no Min alarm will be Input S1: Auto or external reset given exceeding a Min limit if kW % < 5% before External reset: S1 is connected to Gnd by the Tr expires. use of a switch or optocoupler output See fig. 2. Auto reset: If S1 is connected to Gnd, Auto reset mode is enabled, which leads to reset of alarms by hysteresis. Page 2 Page 3

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted