Product Information

DSU D382

DSU D382 electronic component of Unipower

Datasheet
DISPLAY/PGMMING UNIT, APM382, 15-30V

Manufacturer: Unipower
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 599.8888 ea
Line Total: USD 599.89

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Tue. 28 May to Mon. 03 Jun

MOQ : 1
Multiples : 1

Stock Image

DSU D382
Unipower

1 : USD 478.5438

     
Manufacturer
Product Category
No Of Digits / Alpha
Meter Function
Meter Range
Digit Height
Panel Cutout Height
Panel Cutout Width
Supply Voltage Min
Supply Voltage Max
Operating Temperature Min
Operating Temperature Max
Product Range
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
PCU D10 electronic component of Unipower PCU D10

CONTROL/DISPLAY UNIT, APM110E, 15-30V
Stock : 0

HPL500 electronic component of Unipower HPL500

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

HPL110A electronic component of Unipower HPL110A

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

HPL110 electronic component of Unipower HPL110

DIGITAL MOTOR LOAD MONITOR, ANALOGUE O/P
Stock : 0

APM382 electronic component of Unipower APM382

ANALOGUE MOTOR LOAD MONITOR, 24V
Stock : 0

APM110E electronic component of Unipower APM110E

ANALOGUE MOTOR LOAD MONITOR, 230V
Stock : 0

APM112E electronic component of Unipower APM112E

MOTOR LOAD MONITOR, 230V
Stock : 0

DSU D382 electronic component of Unipower DSU D382

DISPLAY/PGMMING UNIT, APM382, 15-30V
Stock : 0

Image Description
E10711 electronic component of ABB E10711

RING TONGUE TERMINAL, 1/4", 6AWG
Stock : 2000

698-532-63 electronic component of Marl 698-532-63

LED INDICATOR, 12-28V AC/DC, GREEN
Stock : 0

10-584269-01S electronic component of Amphenol 10-584269-01S

Circular MIL Spec Connector ER 10C 10#16 SKT PLUG
Stock : 0

701-6546-24 electronic component of Concord 701-6546-24

Nylon Binding Head Screw, 6-32
Stock : 0

SK551E685ZAR electronic component of Kyocera AVX SK551E685ZAR

Multilayer Ceramic Capacitors MLCC - Leaded 100V 6.8 uF 80 -0.2
Stock : 0

698-501-63 electronic component of Marl 698-501-63

LED INDICATOR, 12-28V AC/DC, RED
Stock : 10

701-6625 electronic component of Concord 701-6625

Screws Machine Nylon Round Head Slot Drive 6-32
Stock : 0

264-326 electronic component of Wago 264-326

TERMINAL BLOCK, DIN RAIL, 2POS, 28-12AWG
Stock : 480

698-3R50KDLF electronic component of TT Electronics 698-3R50KDLF

Res Thin Film NET 50K Ohm 0.5% 0.6W ±25ppm/C ISOL Molded 16-Pin DIP Pin Thru-Hole Tube
Stock : 0

701-6625-24 electronic component of Concord 701-6625-24

701662524 concord
Stock : 0

DSU d382 (-DAQ) Unipower Technical Information Version 1.0 Generally Unipower DSU d382 is a display/programming unit for the universal measuring/control unit APM382. The DSU has no measuring circuit and cannot be used without the APM382. The d382 is meant as a supplement for the APM382 if it is required to have the power measurements and the control sta- tus displayed or if programming of the APM382 needs to be done from the front of the control panel without the otherwise necessary connection to a PC. When using an APM382 together with a DSU d382 no high voltage is present in the front of the control panel, so in this way possible future requirements are already met. Features Programming/Display Indicators Setting up the d382 (APM382) is done using three keys on the A number of LEDs indicate to the user the status of the APM382: front The Mode-key is used to select one of the variables/ Ts Lit when Ts is active. parameters and the arrow keys are used to change the value of the Tr Lit together with the limit for which Tr is active. selected parameter. Pressing the Reset-key returns to displaying Limit 1 Lit when Tr for limit 1 is active. Blinking during alarm. kW%. Limit 2 Lit when Tr for limit 2 is active. Blinking during alarm. dP/dt Blinking when a dP/dt alarm has occurred. Per default the parameters are protected against programming. To dU/dt Lit when dU/dt is detected (Indicates fluctuating mains) unlock this protection, select Locked and change On to Off Output1 Lit when output 1 is on, otherwise not lit using the arrow keys. Now all parameters are open for change. If Output2 Lit when output 2 is on, otherwise not lit no key has been activated for 1 minute the Lock is reactivated. Peak detectors When a parameter is changed the new value is send to the APM382 After expiration of Ts the peak detectors are set to the actual after pressing the Mode-key or automatically returning to measurement. From this point on the peak detectors are updated displaying kW% again. To make sure that this new value is transfer- every 20ms. The value of the two peaks - max and min may be red and received correctly, the d382 asks for a confirmation and displayed in the kW% display mode using the arrow keys: displays E r r if the parameter is not as expected. So if no error Key Up Display the max peak. appears in the display the user may be sure that the parameter has Key Down Display the min peak. been programmed correctly. If no connection to the APM382 is present, the display will show ---- Technical Specifications Mechanical Electrical Housing: Noryl Supply: 15 - 30 Vdc Mounting: Panel mounting Consumption: < 1VA Cut-out: 68 x 68 mm Serial output: RS232C IP class: IP54 9.6 kbaud -> APM382 o Temp.: -15 to +50 C 57.6kbaud -> PC (DAQ) Weight: 150g (d382-DAQ 170g) Storage: 1 mill. measurements (DAQ) Dimens.: D 70 x W 72 x H 72 mm CE mark: EN61326-1DSU d382 Parameters Parameter list The majority of the settings are found and altered in a parameter list. To access this list use the Mode-key to light up the Parame- ter LED resulting in the display showing P00. Use the arrow keys to select the desired parameter number (see list below) and press Mode. Now the current value of the parameter is displayed and may be altered with the arrow keys. Remember to unlock the programming protection. To send the new value to the APM382 press the Mode-key and the unit returns to the parameter list. If required select a new parameter as described or return to showing kW% by pressing the Reset-key. Typical connection Extended version - DSU d382-DAQ The DSU d382-DAQ is an extended version of the d382 with a Parameter list built-in Data Acquisition facility. All features of the d382 is also present in the d382-DAQ. This part of the data sheet deals with the additions necessary for acquiring data. Data Acquisition Acquiring data may be done manually, automatically with a trig- ger function or permanently. If activated manually (P16) the data acquisition is not reactivated after a power down of the d382- daq. To achieve this the Restart DAQ - parameter (P20) must be enabled. The trigger may be set as a min- or a max-limit (P18) in which case the data acquisition is started if the measurement drops below the trigger level or exceeds the trigger level respectively. Typical connection The trigger level is also programmable (P19). The rate at which the measurements are sampled may be set from 20ms to 1 second (P17) - see table. When the memory is full, the oldest measurements will be erased and replaced by the current measurements. An LED indicates to the user the status of the data acquisition. The Aux is lit when the data acquisition is active and blinking if the trigger is enabled but the acquisition not yet active. Transferring Data The acquired data may be transferred to a PC with the Unipower Data Acquisition software UniDAQ. Please visit our website www.unipower.dk for download of the software and manual. Connecting the d382-DAQ to a PC is done with a standard straight RS232 cable (SUBD-9 male/female). The d382-DAQ is set up to communicate with the PC via parameter P21, which must be set to PC. If the display shows ---- only this parameter may be altered. Unipower DSU d382

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted