Safety Relays OA5612,24V, 4NO/2NC

Manufacturer: Altech
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

5: USD 82.7466 ea
Line Total: USD 413.733

0 - Global Stock
MOQ: 5  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Tue. 06 Jun to Mon. 12 Jun

MOQ : 5
Multiples : 1
5 : USD 82.7466
10 : USD 59.5804
15 : USD 55.6114
20 : USD 54.5

     
Manufacturer
Altech
Product Category
Safety Relays
Brand
Altech
Product Type
Safety Relays
Factory Pack Quantity :
20
Subcategory
Relays
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image 105-905
Electrical Enclosures TK1313 W/KNOCKOUTS
Stock : 1
Stock Image 110-908
Enclosures, Boxes, & Cases 10.0 x 7.09 x 4.37 Polystyrene Gray
Stock : 1
Stock Image 111-003
Enclosures for Industrial Automation 3.70 x 3.70 x 2.24 Polystyrene Transp
Stock : 1
Stock Image 110-401
Electrical Enclosures 2.56 x 1.97 x 2.24 Polystyrene Gray
Stock : 1
Stock Image 002540011
Fuse Holder Fuse holder,EFD 10,32A,1p,LED
Stock : 1
Stock Image 111-005
Electrical Enclosures 5.12 x 5.12 x 2.95 Polystyrene Transp
Stock : 1
Stock Image 100-405-91
Enclosures for Industrial Automation TGABS1212-6-Os 124x122x55mm
Stock : 1
Stock Image 100-403-91
Enclosures for Industrial Automation TGABS88-6-oS,84x82x55mm
Stock : 1
Stock Image 100-405-01
Enclosures for Industrial Automation TGABS1212-6-o, 124x122x55mm
Stock : 1
Stock Image 08349000700
Circuit Breaker Accessories PULSERELASIS MINI 110V
Stock : 1
Image Description
Stock Image C500CE241

Safety Relays 24PIN Con SOLDERTYPE
Stock : 1

Stock Image 56.OA03.3253C

Safety Relays OA5603,32V, 5NO/3NC
Stock : 1

Stock Image YS1T-RHA38F21PD

Electromechanical Relay DIN Rail Thermal Overload Relay
Stock : 1

Stock Image SR6ZB024

TE Connectivity Schrack Safety Relays 4PST-NODPST-NC 8A 24VDC SAFETY RELAY
Stock : 1

Stock Image TK-E5-65-95

Electromechanical Relay 5A (68x106x105)mm Bracket Thermal Overload Relay
Stock : 1

Stock Image 8951.2N

Safety Relays RM2G1, 1 Channel Safety relay
Stock : 1

Stock Image 7S.12.9.024.5110

Module: safety relay; Series:7S; OUT:2; Mounting: DIN; -40÷70°C
Stock : 0

Stock Image J73KN-AM-22

Safety Relays Aux Contact Block 2NO+2NC
Stock : 1

Stock Image 7S.32.8.230.5110

Module: safety relay; 7S; 230VAC; OUT: 2; DIN; -40÷70°C; IP20; 250V
Stock : 0

Stock Image 7S.32.9.024.5110

Module: safety relay; 7S; 24VDC; OUT: 2; DIN; -40÷70°C; Safety cat: 3
Stock : 0

SafetyRelaysCov2013.QXD Layout 1 10/3/17 2:37 PM Page 1 Altech Corporation 35 Royal Road Flemington, NJ 08822-6000 P 908.806.9400 F 908.806.9490 www.altechcorp.com Altech Corp. 280-5000 Printed March 2013Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality products with superior service. This is the Altech Commitment Altechs line of safety relays are manufactured by , a company well know in Europe for its quality safety relays. The products presented in this catalog will help you meet requirements of Machinery Directive 2006/42/EC, important international safety standards, CE-marking demand, and more, when exporting your machinery or equipment. What is a Safety Relay A safety relay contains force guided contacts they are also known as captive, locked or positive guided contacts. Force guidance in a relay means that the contacts in a contact set must be mechanically linked together so that it is impossible for the NO (normally open) and NC (normally closed) contacts to be closed at the same time. The contacts are linked so that no one contact in a relay can change state without changing all the contacts in that relay. There must be a 0.5 mm minimum air gap between the open contacts for the entire service life of the relay, even in the case of a failure. The force guidance of the relay contacts must always be preserved even when a relay part fails to function correctly. Our technical experts welcome the opportunity to answer your technical questions and provide solutions to your automation and control problems. Give us a call or visit www.altechcorp.com. Quality Commitment Altechs control components meet diverse national and international standards such as UL, NEC, CSA, IEC, VDE and more. Altech provides superior customer service and delivery through Total Quality Management and Continuous Process Improvement. Altech is ISO 9001 approved. We perform these services with honesty and integrity and are committed to achieve these goals.

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial