NLP65 Series
Data Sheet Single, dual and triple output
Total Power: 65 - 75 W
Input Voltage: 85-264 VAC
120-370 VDC*
# of Outputs: Single, dual, triple
SPECIAL FEATURES
Universal Input
3 x 5 footprint
Low profile fits 1U applications
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
65 W with free air convection cooling
EN55022, EN55011 conducted
emissions level B
EN61000-4-2,-3,-4, -5, -6
Electrical Specifications
immunity compliant
Input
RoHS compliant
Input voltage range: Universal input (see Note 2) 85-264 Vac
LPX80 enclosure kit available
NLP65-76xx version only 120-370 Vdc
2 year warranty
Input frequency range: 47-63 Hz
17 A max.
Input current: 120 Vac
SAFETY
(cold start) 230 Vac
32 A max
VDE0805/EN60950-1
Safety ground leakage current: 120 Vac, 60 Hz 0.7 mA
File No. 1040100-3336-0096
230 Vac, 50 Hz 1.4 mA
License No. 114404
Input current: 120 Vac, with PFC 1.4 A
UL 60950-1
230 Vac, with PFC 0.51 A rms
cUL 60950-1
120 Vac, without PFC 1.40 A rms
CCC 60950-1
230 Vac, without PFC 0.80 A rms
CE LVD Directive
Input fuse: UL/IEC127 5 A, 250 Vac In live and neutral
Output
*NLP65-76xx version only
Total regulation: Main output 2.0%
(line and load) Auxiliary outputs 5.0%
Rise time: At turn-on 1.0 s, max
Transient response: Main output 5.0% or 250 mV
25% step max. dev., 1ms max.
at 0.1 A/s recovery to 1%
Temperature coefcient: 0.02%/C
Overvoltage protection: Main outputs 125%, 10%
Short circuit protection: Cyclic operation Continuous
Minimum output current: Single and multiple (See Note 6)NLP65 Series Data Sheet
All specications are typical at nominal input, full load at 25 C unless otherwise stated.
(11, 12)
EMC Charateristics
Conducted emissions: EN55022, FCC part 15 Level B
ESD air: EN61000-4-2, level 3 Perf. criteria 1
ESD contact: EN61000-4-2, level 4 Perf. criteria 1
Surge: EN61000-4-5, level 3 Perf. criteria 1
Fast transients: EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity: EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity: EN61000-4-6, level 3 Perf. criteria 2
General Specifications
Hold-up time: 120 Vac, 60 Hz 16 ms @ 65 W
230 Vac, 50 Hz 78 ms @ 65 W
Efciency: 120 Vac, 65 W 72% typical
Isolation voltage: Input/output 3000 Vac
Input/chassis 1500 Vac
Switching frequency: Fixed 100 kHz, 5 kHz
Approvals and standards: EN60950-1, IEC60950-1
(see Notes 9, 13)
Weight: 283 g (10 oz)
MTBF demonstrated: MIL-HDBK-217F 150,000 hours min
Environmental Specifications
Thermal performance: Operating (See derating curve) 0 C to +70 C
(See notes 1, 3, 10) Non-operating -40 C to +85 C
50 C - 70 C ambient, convection cooled Derate to 50% load
0 C to 50 C, ambient, convection cooled 65 W
0 C to 50 C, ambient 20CFM forced air (See Note 10) 75 W
Peak (0 C to 50 C, 60 s) See table
Relative humidity: Non-condensing 5 to 95% RH
Altitude: Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 5): 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV