Product Information

ES-FA-11AA

ES-FA-11AA electronic component of Banner

Datasheet
RELAY, SAFETY, DPST-NO, 250V, 7A

Manufacturer: Banner
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 366.3993 ea
Line Total: USD 366.4

19 - Global Stock
Ships to you between
Fri. 03 May to Thu. 09 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
14 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1

Stock Image

ES-FA-11AA
Banner

1 : USD 362.9789

     
Manufacturer
Product Category
Coil Voltage
IP Rating
Brand
Contact Configuration
Product Range
Relay Mounting
Contact Current
Relay Terminals
Contact Voltage Ac Nom
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
BTA23S electronic component of Banner BTA23S

BTA23S banner n
Stock : 1

2LM3 electronic component of Banner 2LM3

2-Wire Ac Logic Module
Stock : 1

2PBA electronic component of Banner 2PBA

Switching Power Supplies MULTI-BEAM: 2-wire AC Power Block; Range: depends on sensor; Input: 105-130 V ac; Output: SPST solid-state switch; Wiring Chamber
Stock : 7

D12SP6FP electronic component of Banner D12SP6FP

Fiber Optic Sensor
Stock : 1

BT21S electronic component of Banner BT21S

BT21S banner
Stock : 1

ABR3009-WSU1 electronic component of Banner ABR3009-WSU1

BARCODE READER, 752 X 480 PIXELS
Stock : 1

ABR3106-WSE1 electronic component of Banner ABR3106-WSE1

BARCODE READER, 1280 X 960 PIXELS
Stock : 1

ABR7109-MSE2 electronic component of Banner ABR7109-MSE2

BARCODE READER, 1280 X 1024 PIXELS
Stock : 1

ABR7112-RSE2 electronic component of Banner ABR7112-RSE2

BARCODE READER, 1280 X 1024 PIXELS
Stock : 1

BWC-1MRSFRSB2 electronic component of Banner BWC-1MRSFRSB2

ANTENNA CORD, SMA RP PLUG-BHD JACK, 6.6
Stock : 0

Image Description
C500CE241 electronic component of Omron C500CE241

Safety Relays 24PIN Con SOLDERTYPE
Stock : 1

2904951 electronic component of Phoenix Contact 2904951

Safety Relays PSR-MS25-1NO- 1DO-24DC-SC
Stock : 11

SP10-ETL01 electronic component of Omron SP10-ETL01

INPUT SIMULATOR
Stock : 1

56.OA03.3253C electronic component of Altech 56.OA03.3253C

Safety Relays OA5603,32V, 5NO/3NC
Stock : 1

YS1T-RHA38F21PD electronic component of Idec YS1T-RHA38F21PD

Electromechanical Relay DIN Rail Thermal Overload Relay
Stock : 1

SR6ZB024 electronic component of TE Connectivity SR6ZB024

TE Connectivity Schrack Safety Relays 4PST-NODPST-NC 8A 24VDC SAFETY RELAY
Stock : 1

SR6ZA730 electronic component of TE Connectivity SR6ZA730

RELAY, SAFETY, 3PST-NO, NC, 250VAC, 8A
Stock : 0

TK-E5-65-95 electronic component of Fuji TK-E5-65-95

Electromechanical Relay 5A (68x106x105)mm Bracket Thermal Overload Relay
Stock : 0

8951.2N electronic component of Altech 8951.2N

Safety Relays RM2G1, 1 Channel Safety relay
Stock : 1

J73KN-AM-22 electronic component of Omron J73KN-AM-22

Safety Relays Aux Contact Block 2NO+2NC
Stock : 0

ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules With 3 normally open safety outputs or 2 normally open safety outputs and 1 normally closed auxiliary output Original Instructions Monitors emergency stop devices, such as palm buttons and rope/cable pulls, and posi- tive-opening safety switches used for guard/gate interlocking The safety inputs can monitor: A +24V dc source switched by hard/relay contacts in single-channel hookup, or Hard/relay contacts in a dual-channel hookup using terminals S11-S12 and S21-S22 The ES-FA-9AA has three normally open output switching channels for connection to control-reliable power interrupt circuits The ES-FA-11AA has two normally open output switching channels for connection to control-reliable power interrupt circuits and one normally closed auxiliary output channel Automatic reset or monitored manual reset Design complies with standards ANSI B11.19, UL991, ISO 13850 (EN418), and ISO 13849-1 (EN954-1) (Safety Category 4) For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/ EN60204-1 6 or 7 amp safety output contacts, depending on model Plug-in terminal blocks 24V ac/dc operation Models Supply Voltage Outputs Output Contact Rating ES-FA-9AA 3 Normally Open (NO) 6 A 24V ac/dc ES-FA-11AA 2 Normally Open and 1 Normally Closed (NC) 7 A WARNING: Not a Stand-Alone Safeguarding Device This Banner device is not a stand-alone point-of-operation guarding device, as defined by OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safety light screens and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-of-operation guards on hazardous machinery can result in a dangerous condition which could lead to serious injury or death. Important: Read this First The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications depart- ment at the telephone numbers or address found at ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules ANSI/RIA R15.06 Safety Requirements for Industrial Robots and Robot Systems Contact: Robotic Industries Association, 900 Victors Way, P.O. Box 3724, Ann Arbor, MI 48106, Tel.: 734-994-6088 Applicable International Standards ISO 12100-1 & -2 (EN 292-1 & -2) Safety of Machinery Basic Concepts, General Principles for Design ISO 13849-1 (EN 954-1) Safety-Related Parts of Control Systems ISO 13850 (EN 418) Emergency Stop Devices, Functional Aspects Principles for Design IEC 60204-1 Electrical Equipment of Machines Part 1: General Requirements Contact: Global Engineering Documents, 15 Inverness Way East, Englewood, CO 80112-5704, Tel.: 800-854- 7179 Certificate of Adequacy This Safety Module datasheet satisfies the requirements of Machinery Directive 2006/42/EC, Section 1.7.4 instructions. Overview An Emergency Stop Safety Module is used to increase the control reliability of an emer- ES-FA-9AA ES-FA-11AA gency stop circuit. As shown in the hookup drawings, the models ES-FA-9AA and ES- FA-11AA E-Stop Safety Modules are designed to monitor a 1-channel or 2-channel E- stop switch. A 2-channel E-stop switch has two electrically isolated contacts. Power ON LED WARNING: Safety Categories The level of safety circuit integrity can be greatly affected Channel 1 Active LED by the design and installation of the safety devices and Channel 2 Active LED the means of interfacing of those devices. A risk as- sessment must be performed to determine the appro- priate safety circuit integrity level or safety category as described by ISO 13849-1 (EN 954-1) to ensure the expected risk reduction is achieved and all relevant regulations and standards are complied with. Figure 1. Features and Terminals Safety Circuit Integrity and ISO 13849-1 (EN954-1) Safety Circuit Principles Safety circuits involve the safety-related functions of a machine that minimize the level of risk of harm. These safety-related functions can prevent initiation, or stop or remove a hazard. A failure of a safety-related function or its associated safety circuit may result in an in- creased risk of harm. The integrity of a safety circuit depends on several factors, including fault tolerance, risk reduction, reliable and well-tried components, well-tried safety principles, and other design considerations. Depending on the level of risk associated with the machine or its operation, an appropriate level of safety circuit performance must be incorporated. ANSI/RIA R15.06 Industrial Robots, ANSI B11 Machine Tools, OSHA 29CFR1910.217 Mechanical Power Presses, and ISO 13849-1 (EN954-1) Safety-Related Parts of a Control System standards provide details of the safety performance levels. Safety Circuit Integrity Levels Safety circuits in International and European standards have been segmented into categories, depending on their ability to maintain their integrity in the event of a failure. The most recognized standard that details safety circuit integrity levels is ISO 13849-1 (EN954-1), which establishes five levels: Categories B, 1, 2, 3, and the most stringent, Category 4. In the United States, the typical level of safety circuit integrity has been called control reliability. Control reliability typically incorporates redundant control and self-checking circuitry and has been loosely equated to ISO 13849-1 Categories 3 and 4 (see CSA Z432 and ANSI B11.TR4). If the requirements described by ISO 13849-1 (EN954-1) are to be implemented, a risk assessment must first be performed to determine the appropriate category, in order to ensure that the expected risk reduction is achieved. This risk assessment must also take into ac- count national regulations, such as U.S. control reliability or European C level standards, to ensure that the minimum level of perform- ance that has been mandated is complied with. 2 www.bannerengineering.com - tel: 763-544-3164 P/N 060606 Rev. F

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted