HLMP-1301, HLMP-1401, HLMP-1503, HLMP-K401, HLMP-K600 T-1 (3-mm) Diffused LED Lamps Data Sheet Description Features This family of T-1 lamps is widely used in general-purpose High intensity indicator applications. Diffusants, tints, and optical design are Choice of four bright colors: balanced to yield superior light output and wide viewing High Efficiency Red angles. Several intensity choices are available in each color for Orange increased design flexibility. Yellow High Performance Green Popular T-1 diameter package Selected minimum intensities Wide viewing angle General purpose leads Reliable and rugged Available on tape and reel Package Dimensions 1.14 (.045) 2.79 (.110) 0.51 (.020) 2.29 (.090) 24.1(.95) MIN. CATHODE 1.52 (.060) 3.43 (.135) 0.65 (0.026) max. 1.02 (.040) 2.92 (.115) 3.17 (.125) 2.67 (.105) (0.022) 0.55 SQ. TYP. (0.016) 0.40 4.70 (.185) 4.19 (.165) 6.35 (.250) 5.58 (.220) NOTE 1. All dimensions are in mm (inches). 2. An epoxy meniscus may extend about 1 mm (0.040 in.) down the leads. 3. For PCB hole recommendations, see Precautions. Broadcom - 1 -HLMP-1301, HLMP-1401, HLMP-1503, HLMP-K401, HLMP-K600 Data Sheet Device Selection Guide Luminous Intensity Iv (mcd) at 10 mA Material Color Part Number Min. Max. GaAsP on GaP Red HLMP-1301 3.4 HLMP-1301-E00xx 3.4 HLMP-1301-G00xx 8.6 HLMP-1301-GH0xx 8.6 27.6 Yellow HLMP-1401 2.2 HLMP-1401-D00xx 3.6 HLMP-1401-E0000 5.7 Orange HLMP-K401 2.1 HLMP-K401-E00xx 3.4 HLMP-K401-FGDxx 5.4 17.2 HLMP-K401-FH000 5.4 27.6 GaP Green HLMP-1503 1.0 HLMP-1503-C00xx 2.6 HLMP-1503-D00xx 4.2 HLMP-1503-DE000 4.2 13.4 HLMP-1503-E00xx 6.7 a HLMP-K600 1.0 Emerald Green a. Refer to Application Note 1061 for information comparing standard green and emerald green light output degradation. Absolute Maximum Ratings at T = 25C A Parameter HER/Orange Yellow Green Units Peak Forward Current 90 60 90 mA a 25 20 25 mA Average Forward Current b c 30 20 30 mA DC Current , Reverse Voltage (IR = 100 A) 5 5 5 V d 500 500 500 mA Transient Forward Current (10s Pulse) LED Junction Temperature 110 110 110 C Operating Temperature Range 40 to +100 40 to +100 20 to +100 C Storage Temperature Range 40 to +100 40 to +100 40 to +100 C a. See Figure 5 (HER/Orange), Figure 10 (Yellow), or Figure 15 (Green/Emerald Green) to establish pulsed operating conditions. b. For Red, Orange, and Green series derate linearly from 50C at 0.5 mA/C. For Yellow series derate linearly from 50C at 0.2 mA/C. c. For Red, Orange, and Green series derate power linearly from 25C at 1.8 mW/C. For Yellow series derate power linearly from 50C at 1.6 mW/C. d. The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the Absolute Maximum Ratings. Broadcom - 2 -