Dupline Plug & Play Master Module Interface for Lucky Goldstar PLC Type G 3496 0001 Lucky Goldstar master Plug and play: Automatic communication with specific PLC/Controllers Built-in normal Dupline Channel Generator 128 I/Os and DC power supply on 3 wires RS232/RS422/RS485 port for interfacing to control sys- tem Split-I/O mode selectable (128 inputs and 128 outputs) LED-indications for supply, Dupline carrier and Com- port Tx Galvanically isolated Com-port supplied by internal DC/ DC converter Product Description Ordering Key G 3496 0001 700 G 3496 0001 is designed channel generator, power Type: Dupline as a cost-effective Plug & supply synchronization H4-Housing Play solution for interfacing (enables 3-wire system with Combined module Dupline I/Os to a Lucky supply) and RS232/RS422/ Interface type Goldstar PLC. It performs RS485 interface. DC supply three functions: Dupline Type Selection Supply PLC Interface type Ordering no. 20-30 VDC Lucky Goldstar K-serie G 3496 0001 700 Input/Output Specifications Input/Output Specifications (Cont.) Power output Pin assignment Output voltage 20-30 VDC (pulsating) 2-wire RS 485 Output current < 3.0 A 50C S/R Data line + (B) Pin 3 Short circuit protection 4 A quick acting fuse S/R Data line - (A) Pin 8 Output voltage drop < 1.0 V GND Pin 5 4-wire RS 485/RS 422 Dupline carrier R Data line + (B) Pin 3 Output voltage 8.2 V (pulsating) R Data line - (A) Pin 8 Current < 60 mA S Data line + (B) Pin 2 Short circuit protection Yes S Data line - (A) Pin 7 Scan time Direction Pin 4 128 channels 132.2 ms (Connect to GND pin 5 64 channels 69.8 ms when using 4-wire Communication port communication) Standard RS232/RS422/RS485 RS 232 Split I/O mode Yes, selectable TX Pin 1 Normal Dupline mode Yes, selectable RX Pin 9 Connection 9 pole female Sub-D GND Pin 5 Dielectric voltage Com-port Dupline 1 kVAC (rms) Protocol LG Serial Communication Standard Supply Specifications Baud rate 19200 Data bits 8 Power supply Overvoltage cat. III (IEC 60664) Start bit 1 Operational voltage (V ) 20-30 VDC in Stop bit 1 Reverse polarity protection None Parity None Flow-control None Current consumption < 150 mA + Power load Power dissipation < 5 W Transient protection voltage 800 V Dielectric voltage Supply - Dupline None Supply - com-port 1 kVAC (rms) Note: Use individual power supplies for all G349600xx700, as the input are not galvanic isolated from each other. Specifications are subject to change without notice (02.12.2014) 1 G 3496 0001 General Specifications Power ON delay 2 s Humidity (non-condensing) 20 to 80% Indication for Mechanical resistance Com-port Tx LED, red Shock 15 G (11 ms) Supply ON LED, green Vibration 2 G (6 to 55 Hz) Dupline carrier LED, yellow Dimensions H4-Housing Environment Weight 100 g Pollution degree 3 (IEC 60664) Operating temperature 0 to +50C (+32 to +122F) Storage temperature -50 to +85C (-58 to +185F) Mode of Operation The Dupline Master Module ter. This means that the 128 input coded for B5 is activat- tion available for the PLC (like (DMM) controls a 3-wire bus Dupline I/Os will be read/ ed, the output(s) coded for B5 in normal mode), but it will with signal, DC-power and written by the DMM and then will also be activated. not automatically activate the common GND. The DMM sent to the PLC. Dupline output(s) coded to is connected to a standard Consequently, a Dupline - B5. The Dupline outputs are DC-supply, which it synchron- The DMM can run in two dif- output can either be activat- controlled exclusively through izes with the Dupline carrier ferent modes Normal mode ed through the output-data the output data received from signal before it is output to and split I/O mode. In Normal received on DMM or by an the PLC. In this mode, up supply. The synchronization is mode, Dupline operates as active Dupline input coded for to 128 Dupline inputs and necessary in order to enable a peer-to-peer system, where the same Dupline -address. In 128 Dupline outputs are the Dupline and DC-supply to the channel generator auto- Split I/O mode, the channel available, since an input and share the GND-wire. matically establishes a con- generator treats the Dupline an output coded to the same nection between Dupline inputs and Dupline outputs Dupline address can operate The Dupline Master Module is inputs and Dupline outputs independently. If e.g. an input independently. a Dupline Channel Generator which are coded to the same coded for B5 is activated, the with the function of a mas- Dupline address. If e.g. an DMM will make the informa- Wiring Diagram Pin Assignment Only for G 2196 0001 1 23 4 5 6 7 8 3W 1 RS 232 6 RS 485 2 7 3 + - 8 4 9 22 24 26 27 28 5 21 23 25 Power out Supply in 20-30 V DC GND Dupline Signal Dip-Switch Setting Installation Hints Sw.4 On: Split I/O Channel Generator Mode No TX-LED (See Mode of Operation) Hardware fault Check the wiring. Off: Normal Dupline Monostable Channel No Dupline Carrier-LED Generator Mode Sw.5 On: 64 Dupline channels Short circuit Short circuit between the Off: 128 Dupline channels two Dupline wires. 2 Specifications are subject to change without notice (02.12.2014)