Master Channel Generator Du line Types G 3800 0016, G 3800 1016 Fieldbus Installationbus Programmable channel generator Automatic data exchange between multiple networked Master Generators, allowing systems with up to 4096 I/O points Option for built-in GSM Modem for monitoring and control via SMS User-friendly configuration via Windows 98/2000/NT/XP software Real-time, timer and logic functions Analog set-point control and monitoring Light and Rollerblind control functions Alarm Monitoring Option for Radio controlled clock for high real time accuracy 2 x RS232 ports for configuration and Dupline data read/write 1 x RS485 port for networking of up to 32 Master Generators Modbus-RTU protocol Built-in software driver for external radio modem 4 digital inputs / 4 digital outputs on-board H8-housing for DIN-rail mounting (EN50022) AC or DC power supply Product Description Ordering Key G 3800 1016 230 Programmable channel gene- as slaves in a RS485 network Type: Dupline rator with built-in dedicated using the Modbus protocol. H8-housing intelligent functions for light The unit has 4 digital inputs GSM phone and roller blind control, alarm and 4 digital outputs on- Master channel generator monitoring and analog set- board, and it is possible to Supply point control. In addition to create links to other Dupline that, there is realtime-, timer- networks via external Radio and logic- functions. Pro- Modem. The G3800X016 is gramming is easily performed different from the G3800X015 Type Selection through Windows-based con- in that it has the capability to figuration software. An perform automatic data Supply Ordering no. Ordering no. optional built-in GSM modem exchange with up to 32 other w. GSM telephone can be used for monitoring G3800X016s in a RS485 net- and control of Dupline signals work, enabling up to 4096 115/230 VAC G 3800 0016 230 G 3800 1016 230 via SMS. Up to 32 Master I/O-points in one system. 10-30 VDC G 3800 0016 800 G 3800 1016 800 generators can be networked Input/Output Specifications Sequence time Serial Port RS 232 32 channels / 128 channels 38.6 ms / 132.3 ms COM 1 115 kBaud COM 2 9600 Baud, adjustable Digital outputs 4 PNP transistors Function Programmable Data format 8 bit Output voltage VDD 35 VDC COM 1, COM 2 No parity, 1 stop bit Output current 100 mA 9-pole female SUB-D Output voltage drop 2 V Pin assignment TxD Pin 2 Off-state leakage current 100 A RxD Pin 3 Short-circuit protection None GND Pin 5 Built-in protective diodes None Dielectric voltage Dielectric voltage Com.port - Dupline 2 kVAC (rms) Output - Dupline 4 kVAC (rms) Protocol Modbus-RTU Output - Input 200 V RS 485 Termination Pin 27 When in use, Inductive loads External noise suppression connect to pin 31 required Fs-B Pin 28 When in use, Inputs connect to pin 30 Digital 6 - 30 VDC Fs-A Pin 29 When in use, Voltage ON > 5.5 V OFF < 1.5 V connect to pin 31 Current 6 mA + (B) Pin 30 Dielectric voltage - (A) Pin 31 Input - Dupline 4 kVAC GND Pin 32 *) GSM Modem V+ Pin 33 Siemens cellular engine TC35 Protocol Modbus-RTU Dual Band EGSM900 and GSM1800 Dupline Output Dupline carrier Output power Class 4 (2 W) EGSM900 Output voltage 8.2 V Class 1 (1 W) GSM1800 Current < 130 mA Antenna connector FME Short-circuit protection Yes *) V+ and GND may be used as supply for digital I/Os, if RS 485 is not used. Specifications are subject to change without notice (01.09.2008) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupG 3800 0016, G 3800 1016 Du line Fieldbus Installationbus Supply Specifications (cont.) Supply Specifications Power supply AC-Types Overvoltage cat. III (IEC 60664) Inrush current 1 A Rated operational voltage Rated impulse withstand volt. 800 V through term. 21 & 24 Dielectric voltage jumper term. 22 & 23 230 VAC 15% (IEC 60038) Supply - Dupline 500 V Power on term. 21 & 23 Supply - Output 200 V Neutral on term. 22 & 24 115 VAC 15% (IEC 60038) Frequency 45 to 65 Hz Rated operational power Typ. 7 VA/3 W Power dissipation General Specifications G38000016 6 W G38001016 7 W Real-time clock Rated impulse withstand Accuracy Better than 1 minute/month voltage 230 V 4 kV Internal back-up time Typ. 48 hours 115 V 2.5 kV Power ON delay < 2.5 s Dielectric voltage Indication for Supply - Dupline 4 kVAC (rms) Supply ON LED, green Supply - Output 4 kVAC (rms) ON Line LED, yellow Supply - Input 4 kVAC (rms) COM 1 LED, red Supply - Com. ports 4 kVAC (rms) COM 2 LED, red Heat dissipation 4 W RS 485 LED, red GSM LED, red Power supply DC-Types Overvoltage cat. III (IEC 60664) Environment Rated operational voltage Degree of protection IP 20 through term. 21 & 22 10 to 30 VDC Pollution degree 3 (IEC 60664) DC supply Operating temperature 0 to +50C (+32 to +122F) terminal 24 and 25 - 50 Hz for synchronizing Storage temperature -20 to +85C (-4 to +185F) the clock - in case of voltage break Humidity (non-condensing) 20 to 80% RH (AC) the log will automatically Mechanical resistance update itself until 10 mSec Shock 15 G (11 ms) before the loss of current Vibration 2 G (6 to 55 Hz) Reverse polarity protection Yes Dimensions Rated operational power 6 W Material Power dissipation (seeTechnical Informatio) H8-housing G38000016 6 W Weight 640 g G38001016 7 W Wiring Diagrams V+ V- V+ 6-30 VDC DUPLINE G38000016230 D+ 1 23 4 IN D - V- 0,1 A 192314516718 101 123 145 16 30 V 1 23 4 12 34 12 VA Inputs Outputs 21 223233243253263273283290123456 TFs-BFs-A (B) (A) V- V+ 115V 115V V+ S-in V - P NNP RS 485 Out Radio Contr. Supply Clock 6-30 VDC V+ V- V+ DUPLINE G38000016800 D+ 1 23 4 IN D - V- 192314516718 101 123 145 16 1 23 4 12 34 Inputs Outputs + - 21 223233243253263273283290123456 (B) (A) V- V+ TFs-BFs-A V+ - S-in V Supply RS 485 Out Radio Contr. 10-265 VAC Clock 10-30 VDC AC monit. input 2 Specifications are subject to change without notice (01.09.2008) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group