DuplineSafe Safety Input Module Type GS 7510 2101 Bus-powered input module Single input for potential-free contacts Small dimension IP67 housing for de-central installation at the actual location of the switch Safety approved according to IEC/EN 61508-SIL3, IEC/EN 62061-SIL3 and ISO/EN 13849-1 PL e Approval authority: TV Rheinland Group Uses two Dupline channels Operates on a standard Dupline network It is possible to use DuplineSafe modules and standard Dupline modules on the same bus Address coding with GS73800080 Typically used for emergency stops or other NC safety contacts Product Description Ordering Key GS 7510 2101 Bus-powered safety input de-central installation, e.g. DuplineSafe module approved according inside a pull-cord switch. Housing to IEC/EN 61508-SIL3, The module is always used Buspowered input module IEC/EN 62061-SIL3 and in conjunction with the ISO/EN 13849-1 PL e by DuplineSafe Safety Relay GS TV. The module has a sin- 38300143230. The safe gle input for potential-free state signal is transmitted contacts, and it uses two continuously to the Safety Dupline channels for send- Relay as long as the input Input Specifications ing the safety signal. The contacts are closed and the small dimension IP67 hous- module self-check is OK. Inputs 1 NC Contact ing makes it suitable for Open loop voltage 2.5 V Short-circuit current 100 A Contact resistance < 1k Type Selection Cable length max. 2.5 m Dielectric voltage Supply Ordering no. Inputs Dupline None DuplineSafe Safety Input Module Response time 1 By Dupline GS 7510 2101 From input contact opens to safety relay releases max 300 ms Response time 2 From input contact closes Safety Specifications to safety relay activates max 600 ms Standards IEC/EN 61508-SIL3 IEC/EN 62061-SIL3 ISO/EN13849-1 PL e Approval authority TV Rheinland Group General Specifications SFF 96% -6 Power ON delay < 5s PFD (T1 = 1 year) 5.0 x 10 -9 PFH 5.9 x 10 /h Environment Degree of protection IP 67 Pollution degree 3 (IEC 60664) Operating temperature -40C to 70C Storage temperature -40 C to 70C Humidity (non-condensing) 20 - 80% Supply Specifications Mechanical resistance Shock 15 G (11 ms) Power Supply Supplied by Dupline Vibration 2 G (6 to 55 Hz) Reverse polarity protection Yes Current consumption Typ. 1,0 mA Housing Material Valox PBT, Yellow Dimensions 57,5 x 36,0 x 16,4 mm Termination Cable Material PVC, Black Length 300 mm 2 Dimension 6 x 0.5 mm Specifications are subject to change without notice (02.04.2013) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupGS 7510 2101 Mode of Operation The DuplineSafe Safety GS75102101s fails to send Please refer to the user Safety Transmit channel 1 Input module GS75102101 the safe state signal the manual for the DuplineSafe and Safety transmit channel is used to monitor the status Safety Relay will release. Configuration Unit 2 are used by the of one potential-free contact GS73800080 for detailed GS75102101 to transmit the in a safety device, e.g. an instructions on how to status of the safety switch in Addressing emergency stop palm button configure the Safety a dynamic way, ensuring For addressing of or pull cord switch. The sta- Transmitter GS75102101 redundancy, diversity and GS75102101, the Dupline- tus of the safety contact is with the desired addresses. continuous updating. Each Safe Configuration Unit continuously transmitted on GS75102101 must be coded GS73800080 is used. The the Dupline bus using a for a unique channel pair not The synchronization channel GS75102101 must have 3 dynamic signaling principle used by any other is used by the Safety Relay Dupline channels assigned on two Dupline channels. GS75102101. to send out a synchroniza- to it The Safety Input module is Please refer to the datasheet tion signal to the Safety always used in conjunction Synchronization channel for the safety relay Input modules on the bus. with the DuplineSafe Safety (same for all safety GS38300143230 for detailed Therefore, all the Safety Relay GS38300143230, transmitters) instructions how to ensure Input modules and the Safe- which can monitor up to 63 correct addressing, installa- Safety Transmit channel 1 ty Relay must be coded for Safety Input modules all tion and configuration of a the same synchronization Safety Transmit channel 2 connected to the same DuplineSafe safety system. channel. Dupline bus. If one or more Installation Rules Due to fact that the Dupline- stop button must be exclud- 13849-2 table D.6 (see ule is placed very close to Safe input module is a single ed. This is possible, when below) are met. the E-Stop push-button and channel device (one input), the conditions, which are in a closed housing, which there are specific installation mentioned in EN ISO 13849- meets IP 54 rating or higher. - The E-Stop button must rules that have to be 2 table D.4 (see below), are The push-button and the meet the requirements for followed in order to achieve met. cabling must not be direct opening according to an installation complying stressed by external EN 60947-5-1 Annex K. In with IEC/EN 61508-SIL3, mechanical influences. The - Short circuits between the this case it is ensured, that IEC/EN 62061-SIL3 and E-Stop push-button must adjacent terminals at the the contact in the E-Stop ISO/EN 13849-1 PL e: have been approved accord- input of the input module button opens, when the ing to EN 60947-5-1 for and between the terminals at push-button is pressed (see direct opening. - A short circuit between the E-Stop push-button table D.8 in EN ISO 13849-2 the 2 wires in the cable must be excluded. This is below). between the terminals of the possible, when the condi- These 3 conditions are usu- input modules and the E- tions mentioned in EN ISO ally fulfilled, if the input mod- Table D.4 Conductors/cables Fault considered Fault exlusion Remarks Short-circuit between any two Short-circuit between conductors wich are 1) Provided both the conductors conductors and enclosed meet the appropri- - Permanently connected (fixed) and protected ate requirements (see EN 60204-1 against external damage, e.g. by cable ducting, (IEC 60204-1)) armouring, or - seperate multicore cables, or - within an electrical enclosure (se remark 1)), or - individually shielded with earth connection. Short-circuit of any conductor to Short-circuits between conductors which are within - an exposed conductive part or to an electrical enclosure (see remark 1). earth or to the protective bonding conductor. Open-circuit of any conductor None - 2 Specifications are subject to change without notice (02.04.2013) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group