Panel Actuators and Indicators
Type PB
Long-handle Selector Switches
22mm (0.87) Standard and bezel style
Self-hold or spring return
Knob colour choice
Two and three positions
cULus and CE
IEC/EN 60947-5-1, UL 508, IEC/EN 60073, IEC/EN 60529
PB 22S
PB 22B
Product description Ordering key
PB 22S LRS 32 R
Selector switches are to switch between two/three Series
mechanical switches that can electric circuits. Dimension and Style
be turned right, center or left They should be ordered in Type
to open or to close the electric parts (operator + holder + Action
contacts. They are mostly contact block) and installed in Colour
used to start/stop devices or an enclosure.
Approvals Dimensions and styles
22S = 22mm (0.87) Standard style
22B = 22mm (0.87) Bezel style
3MHG
Type Actions (the arrows indicate the spring return function)
LRS = Long-handle selector switch 21 = Two positions L R 32 = Three positions L C R
22 = Two positions L C 33 = Three positions L C R
23 = Two positions C R 34 = Three positions L C R
31 = Three positions L C R
Colours General data
R= Red Y= Yellow Peripheral of actuator AL
K= Black G= Green Actuator Pa
4
Mechanical life 30 x 10 cycles
Operating temperature -25 to +70C (-13 to +158F)
Storage temperature -30 to +80C (-22 to +176F)
Degree of protection IP 65
Dimensions - Push Buttons mm/inches
27/1.06 29/1.14
29/1.14 27/1.06
25/0.98 7/0.27
7/0.27 25/0.98
max
max
22/0.87
22/0.87
S Style B Style
1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or custumization, please ask to our sales network. 122011
24/0.94
16/0.63
24/0.94
16/0.63Panel Actuators and Indicators
Type PA2
Contact Block
High switching power
Double switch
Industrial applications
10A switching capacity
Up to 500VAC
Modular mounting (up to 3 elements)
Screw terminals
High reliability
cULus and CE
According to EN ISO 13850 (only NC slow action)
IEC/EN 60947-5-1, IEC/EN 60947-5-5, UL 508
PA2110/1
Product description Ordering key
PA 2 110 / 1
Switching element equipped pole single throw (SPST) or Type
with two independent elements. double pole single throw Number of contacts
Available in different switching (DPST). Contact code
configurations. Pole and throw Elements can be snapped to each Options ( 1 = Snap action
configurations can be single other on the bottom, up to 3. 2 = Slow action with forced opening NC contact)
Approvals Contact code
Contact configuration Contact code
2 NO contacts (DPST) 200
3MHG
2 NC contacts (DPST) 020
1 NC contact (SPST) 010
Technical data
1 NO contact (SPST) 100
Contact resistance 50m
1 NC + 1 NO contacts (DPST) 110
Travel 5.8 0.2mm (2.28 0.08)
Rated insulation Voltage U 660VAC/DC (acc. to IEC 60947-5-1) Contact characteristics
i
600VAC/DC (acc. to UL508)
Contact Rating AC1 10A @ 250VAC
Rated imp. withstand voltage U 2500VAC 50Hz 1min.
imp
Contact Rating AC15 DC13
Minimum switching power
(acc. to IEC 60947-5-1) @ 24V 10A 6A
Min Current 100mA
@ 110V 8A 1A
Min Voltage 24V
@ 220V 6A 0.5A
Switch housing PC
@ 380V 4A -
Contact parts Cu @ 500V 2.5A -
Contact material AC Contact Rating (acc. to UL 508) A600 B600
B600 (all snap codes) @ 120V 6A 3A
Standard Hard silver
A600 (all slow codes) @ 240V 3A 1.5A
Optional Gold/silver
@ 480V 1.5A 0.75A
Optional for aggressive atmospheres Silver/palladium
@ 600V 1.2A 0.6A
Operating temperature -25 to +70C (-13 to +158F)
DC Contact Rating (acc. to UL 508) Q600 Q300
Storage temperature -30 to +80C (-22 to +176F)
Q600 (all snap codes) @ 125V 0.55A 0.55A
Q600 (100, 200 slow codes) @ 250V 0.27A 0.27A
Q300 (010, 020, 110 slow codes) @ 480V 0.10A -
Terminals
@ 600V 0.10A -
Maximum current, amperes (acc. to UL508)
Maximum
Screw terminals
volt-amperes
120V 240V 480V 600V
2
Max. section sigle-core wire 2 x 2.5mm (0.004sq.inch)
Make Break Make Break Make Break Make Break Make Break
2
Max. section stranded wire 2 x 1.5mm (0.002sq.inch)
A600 10 60 6.00 30 3.00 15 1.5 12 1.2 7200 720
Copper conductor wire 14 AWG @ 60C or 75C
B600 5 30 3.00 15 1.50 7.50 0.75 6 0.6 3600 360
CU conductor
Maximum
Terminal tightening torque 1.2Nm (10.6in.lb.)
Maximum current, amperes (acc. to UL508) make or break
volt-amperes
@ 300V or
125V 250V 301 to 600V
less
Q600 2.5 0.55 0.27 0.10 69
Dimensions mm/inches
Q300 2.5 0.55 0.27 - 69
Wiring diagram
13 23 11
13 11
2NO 2NC 1NC
14 24 12
14 12
13 13 11
1NO 1NO+1NC
32/1.26
14 14 12
Specifications are subject to change without notice. Pictures are just an example. For special features and/or custumization, please ask to our sales network. 122011 2
29/1.14
24/0.94
Contact rating Contact
code rating code
designation designation
Thermal Thermal
continous test continous test
current, current,
Amperes Amperes