T t y f p e r p e a g p Switching Power Supply Type SPD 120W New DIN rail mounting Installation on DIN Rail 7.5 or 15mm Short circuit protection PFC standard High efficiency Power ready output LED indicator for DC power ON LED indicator for DC low Parallel versions standard Compact dimensions UL, cUL listed and TUV/CE approved Class I Div 2 Groups A, B, C, D approved Product De scription Ordering Key SP D 24 120 1 B N The Switching power and compact dimensions Model supplies SPD series are and performance are a Mounting ( D = Din rail ) specially designed to be must. Then version features Output voltage used in all automation PFC and parallel function as Output power application where the standard. Input type installation is on a DIN rail Optional features New Type Input type: 1= single phase Approvals Rheinland Product Safety Optional Features Description Code Standard screw terminal Nil Plug-in connectors B Output Performances DC ON LED (VDC) DC LO LED (VDC) Rated Voltage Trim Range Thereshold at star- Thereshold after output Output Output Typical Model Voltage Power (W)Current (A) tup startup Efficiency (VDC) Min. VDC Max. VDC Min. Max. Min. Max. SPD12120 12 120 10 11.4 14.5 10 11.2 10 11.2 84% SPD24120 24 120 5 22.5 28.5 17.6 19.4 17.6 19.4 86% SPD48120 48 120 2.5 45.0 55.0 37.0 43.0 37.0 43.0 87% Output Data Output voltage accuracy - 0 +1% max (factory adjusted) Ripple and noise Vi nom, Io nom BW = 20Mhz 50mVpp Line regulation 0.5% Hold up Time Vi = 115VAC 25ms Load regulation Hold up time Vi = 230VAC 30ms Non parallel mode 1% Minimum load 0% Parallel mode 5% Parallel Operation 3 units max. Temp. coefficient 0.03% / C Transient recovery time 2ms 1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 11/08/17 t p r a r u o a v B e dSwitching Power Supply Type SPD 120W N DIN rail mounting Input Data Rated input voltage 115/230VAC autoselect Frequency range 47- 63 Hz Voltage range Inrush current AC in, 115 90 - 132VAC Vi= 115VAC 24A AC in, 230 180 - 264VAC Vi= 230VAC 48A DC in 210 - 370VDC P.F.C. Rated input current 2.2 / 0.83A Passive 230VAC Io nom 0.7 Input current Leakage current Vi 90 / 180 VAC Input-Output 0.25mA Max. 2.8 / 1.4A max Input-Fg 3.5mA Max. Controls and Protections 1) Input Fuse T3.15/250VAC internal Rated Overload Protection 110 - 145% Power ready (only SPD 24) Overvoltage Protection Threshold at start up 17.6 - 19.4VDC Vi nom 0.8 Ionom 30 - 33VDC (contact closed) Contact rating at 60VDC 0.3A Output Short Circuit Current limited Insulation 500VDC 1) Fuse not replaceable by user General Data ( nominal line, full load, 25C ) Ambient temperature -35C to 71C Case material Metal (powder painted aluminium) Derating (>60C to +71C) 2.5% / C Dimensions L x W x D Ambient humidity 20 to 95%RH Screw terminal type 124.5 x 64 x 126 Storage temperature -40C to +85C Detachable connector type 143.5 x 64 x 126 Protection degree IP20 Weight 920g Cooling Free air convection Switching frequency 55kHz MTBF (MIL-HDBK-217F) 450.000h Approvals and EMC Insulation voltage I / O 3.000VAC min CE EN50081-1 EN55022 class B Insulation resistance 100M min EN61000-3-2 UL / cUL UL508 listed, UL60950-1 EN61000-3-3 Recognized EN61000-6-2 TUV EN60950-1 EN61000-6-3 EN55024 ISA 12.12.01 Class I Div 2 Groups A, B, C, D Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 11/08/17 2