Product Information

VMU11000V

VMU11000V electronic component of Carlo Gavazzi

Datasheet
Other Modules EOS-ARRAY ISOLATION ENHANCEMENT UNIT

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 92.6497 ea
Line Total: USD 92.6497

5 - Global Stock
Ships to you between
Mon. 02 Oct to Fri. 06 Oct
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
5 - Global Stock


Ships to you between Mon. 02 Oct to Fri. 06 Oct

MOQ : 1
Multiples : 1

Stock Image

VMU11000V
Carlo Gavazzi

1 : USD 93.7519
5 : USD 89.0662
10 : USD 84.6038

     
Manufacturer
Carlo Gavazzi
Product Category
Other Modules
RoHS - XON
N Icon ROHS
Packaging
-
Brand
Carlo Gavazzi
Factory Pack Quantity :
0
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050
Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 1
A82-20500 electronic component of Carlo Gavazzi A82-20500
Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 1
AD2000 electronic component of Carlo Gavazzi AD2000
Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1
AQ1038 electronic component of Carlo Gavazzi AQ1038
Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1
AD1040 electronic component of Carlo Gavazzi AD1040
Power Analysers WM4-96 BASE REV.0
Stock : 1
AO1032 electronic component of Carlo Gavazzi AO1032
Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1
5100532 electronic component of Carlo Gavazzi 5100532
Panel Meters and Controllers Panel Meter Modular
Stock : 1
ACR1252U electronic component of Carlo Gavazzi ACR1252U
USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0
AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC
LATCH UNIT 100-25A
Stock : 1
APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01
Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1
Image Description
RED LED electronic component of Seeed Studio RED LED

Module: LED; LED diode 5mm red; Grove; 3.3÷5VDC; 20x20x20mm
Stock : 0

GREEN LED electronic component of Seeed Studio GREEN LED

Module: LED; LED diode 5mm green; Grove; 3.3÷5VDC; 20x20x20mm
Stock : 1

OKY2105 electronic component of OKYSTAR OKY2105

Module: shield; prototyping; Application: ARDUINO
Stock : 0

2281200-R electronic component of Microchip 2281200-R

Other Modules ACK-I-HDmSAS-mSAS-.5M
Stock : 1

OKY3370 electronic component of OKYSTAR OKY3370

Robot.access: adapter; ESP-07,ESP-12,ESP-12E
Stock : 0

OKY3418 electronic component of OKYSTAR OKY3418

Battery accessories: voltage indicator; 40x25x11mm
Stock : 0

FIT0779 electronic component of DF Robot FIT0779

Robot.access: left wheel; Pcs: 1; Plating: rubber; screw; 65mm
Stock : 1

FIT0780 electronic component of DF Robot FIT0780

Robot.access: right wheel; Pcs: 1; Plating: rubber; screw; 65mm
Stock : 1

FIT0765 electronic component of DF Robot FIT0765

Robot.access: left wheel; Colour: black; Pcs: 1; Plating: rubber
Stock : 1

FIT0766 electronic component of DF Robot FIT0766

Robot.access: right wheel; Colour: black; Pcs: 1; Plating: rubber
Stock : 1

Energy Management Control solution for solar PV applications Type Eos-Array Modular local control system for PV plants Up to 17 DIN modules configuration equivalent to 280mm width Eos-ArraySoft freeware software for easy product configuration Eos-Array can be formed by maximum 17 units Eos-Array can manage in addition to VMU-M master unit up to: - 1 VMU-P unit - max 15 VMU-S units - max 7 VMU-O units - max 1 VMU-1. VMU-M, master module and data logger Master communication capability RS485 communication port (Modbus) Local communication bus management up to 15 mixed VMU-S, VMU-P and VMU-O units Two digital inputs Two temperature inputs: Pt100 or Pt1000 Single virtual or real alarm set-point connectable to any available variable Data and event stamping system Display readout: 6 DGTs 12 to 28 VDC power supply Dimensions: 1-DIN module Protection degree (front): IP40 Product Description How to order VMU-M 4 A S1 T2 X Eos-Array is a combination vide by means of VMU-O Model of modules which performs modules two relay outputs Function a complete control of a pho- so to manage alarms or/and Power supply tovoltaic plant. The core unit external loads (like a lighting Communication is VMU-M which performs system, a module washing Inputs the local bus management system and so on) and two Option of VMU-S, VMU-P both temperature inputs. These measuring units and VMU-O latter two measuring inputs I/O unit. VMU-M assigns can become, according to the proper local unit address the programmed function, automatically (up to 15 units) also two digital inputs. and gathers all the local Housing for DIN-rail mount- measurements coming from ing, IP40 (front) protection VMU-S and VMU-P measur- degree. ing units. VMU-M can pro- Type Selection Function Power supply Communication Inputs 4: Data storage A: From 12 to 28VDC S1: RS485 Modbus (*) T2: two temperature 4Mbyte (*) (*) inputs or two digital inputs for free of voltage reading contacts (*) Option (*) as standard. X: none Specifications are subject to change without notice Eos-Array DS 140911 1Eos-Array VMU-S, string measuring unit Direct DC voltage measurement up to 1000V Energy measurements: kWh Direct DC current measurement up to 16A or up to 30A without fuse Instantaneous variables data format: 4 DGTs Energies data format: 6 DGT Instantaneous variables: V, A, W. Accuracy: Class 1 (kWh) 0.5 RDG (current/voltage) Auxiliary power supply from VMU-M unit Integrated 10.3x38mm fuse holder for string String alarm management by means of VMU-M unit protection only Dimensions: 1-DIN module Fuse blow detection by means of VMU-M unit only Protection degree (front): IP40 PV module connection control by means of VMU-M unit only Product Description How to order VMU-S AV10 X S FX Variables measuring unit or 30A depending on the Model with built-in protection fuse- model. Moreover the unit is Range holder (the fuse is not pro- provided with an auxiliary Power supply vided) particularly indicated serial communication bus. Communication for DC current, voltage, Alarms, fuse blow detec- Option power and energy metering tion, PV module connection in PV solar applications. The and serial communication current inputs/outputs and are managed by means of also the voltage inputs are VMU-M module. Housing made so to simplify the for DIN-rail mounting, IP40 string common connections. (front) protection degree. Direct connection up to 16A Type Selection Range Power supply Communication Option AV10: 1000V DC, 16A X: from 12 to 28VDC, S: auxiliary communica- XX: none (no fuse holder) (Direct connection) (*) self-power supply tion bus, compatible FX: with fuse holder AV30: 1000V DC, 30A from VMU-M unit only to VMU-M module (Direct connection) (**). (*) In this case the Option is XX. (*) as standard. (**) on request. 2 Specifications are subject to change without notice Eos-Array DS 140911

Tariff Desc

8473.30.00 - Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED: Free
62 No .Cards (including network, sound, video, IDE, SCSI, and other similar cards)
Carlo Gavazzi Computing Solutions