Ordering information AC-DC Power Supplies Enclosed Type PB A 10 F -O -O PBA10F 1 2 3 4 5 6 1 Ser ies name Example recommended EMI/EMC filter R 2 Single output NAC-06-472 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *5 C : with Coating G : Low leakage current E : Low leakage current High voltage pulse noise type : NAP series and EMI class A Low leakage current type : NAM series T : V ertical terminal block * A higher current rating EMI/EMC filter J : Connector type may be recommended in view of the N : with Cover other devices that could be connected in parallel with the power supply. (UL508 is acquired) N1 : with DIN rail and Cover V : Output voltage setting potentiometer external- ly Cover is optional *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. MODEL PBA10F-5 PBA10F-12 PBA10F-24 MAX OUTPUTWATTAGE W 10 10.8 12 DC OUTPUT 5V 2A 12V 0.9A 24V 0.5A SPECIFICATIONS MODEL PBA10F-5 PBA10F-12 PBA10F-24 ( ) VOLTAGE V AC85 -264 1 or DC110- 370 AC50 or DC70 Please refer to the instruction manual 2.1 Inputvoltage 3 f * ( ) ACIN 100V 0.30typ Io=100% CURRENT A ( ) ACIN 200V 0.20typ Io=100% ( ) FREQUENCY Hz 50/60 47- 440 or DC INPUT ACIN 100V 74typ 76typ 77typ EFFICIENCY % ACIN 200V 74typ 76typ 77typ ACIN 100V 15typ (Io=100%) INRUSH CURRENT A ACIN 200V 30typ (Io=100%) LEAKAGE CURRENT mA 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, Accordingto IEC60950-1,DENAN) VOLTAGE V 51224 CURRENT A 2 0.9 0.5 6 LINE REGULATION mV * 20max 48max 96max 6 LOAD REGULATION mV * 40max 100max 150max 1 0to +50 * 80max 120max 120max C RIPPLE mVp-p 1 -10- 0 * 140max 160max 160max C *1 0to +50 120max 150max 150max C RIPPLE NOISE mVp-p *1 OUTPUT -10- 0C 160max 180max 180max 0to +50C 50max 120max 240max TEMPERATURE REGULATION mV -10to +50 60max 150max 290max C DRIFT mV *2 20max 48max 96max START-UP TIME ms 200typ(ACIN 100V, Io=100%) Start-up time is 700mstyp forlessthan 1minute of applying input again from turning off the inputvoltage. * HOLD-UP TIME ms 20typ (ACIN 100V, Io=100%) OUTPUTVOLTAGE ADJUSTMENT RANGE V 4.50- 5.50 10.0- 13.2 19.2 - 27.0 OUTPUTVOLTAGE SETTING V 5.00- 5.15 12.00 - 12.48 24.00- 24.96 OVERCURRENT PROTECTION Worksover 105%ofrated current and recovers automatically PROTECTION OVERVOLTAGE PROTECTION V 5.75- 7.00 15.0- 18.0 30.0 - 37.0 CIRCUIT AND ( ) OPERATING INDICATION LED Green OTHERS REMOTE ON/OFF None , , , ( ) INPUT-OUTPUT AC3 000V 1minute Cutoff current= 10mA DC500V 50MWmin At Room Temperature , , , ( ) ISOLATION INPUT-FG AC2 000V 1minute Cutoff current= 10mA DC500V 50MWmin At Room Temperature , , ( ) OUTPUT-FG AC500V1minute Cutoff current= 25mA DC500V 50MWmin At Room Temperature OPERATINGTEMP.,HUMID.ANDALTITUDE -10 to +71 (Required Derating), 20- 90%RH (Non condensing) 3,000m (10,000feet) max C STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75 , 20- 90%RH (Non condensing) 9,000m (30,000feet) max C ENVIRONMENT 2 VIBRATION 10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y andZ axis 2 ( ), , , IMPACT 196.1m/s 20G 11ms once eachX Y and Z axis ( ) , ( ), , AGENCY APPROVALS At onlyACinput UL60950-1 C-UL CSA60950-1 EN60950-1 EN50178 Complies with DEN-AN SAFETY AND , , , , NOISE CONDUCTED NOISE Complies withFCC Part15 classB VCCI-B CISPR22-B EN55011-B EN55022-B REGULATIONS ( ) 7 HARMONICATTENUATOR Complies with IEC61000-3-2 Notbuilt-into active filter 4 * * ( )( ) ( ) CASE SIZE/WEIGHT 31 78 68mm 1.22 3.07 2.68 inches without terminalblock W H D / 150g max with cover : 180g max X X X X X X OTHERS COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN *5 Please contact us about saf ety approvals for the model with option. :RM101). *6 Please contact us about dynamic load and input response . *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *7 Please contact us about class C . *3 Derating is required. * P arallel operation with other model is not possible. *4 When two or more units are used,they may not comply with the harmonic attenuator. Please * Der ating is required when operated with cover. contact us for details. * A sound ma y occur from power supply at peak loading. PBA/PBW-2PBA10F Block diagram FUSE AC250V 2.5A INRUSH RECTIFIER AC IN NOISE CURRENT AND FILTER 85 - 264V FILTER LIMIT FG TRANSFORMER RECTIFIER CONTROL INVERTER AND DC OUT FILTER CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. 18 2.5 LED 0.71 0.1 Voltage adjust 16.52 68 1.5 12.2 0.65 2.68 0.48 Cover name plate M3 2-M3 Mounting hole +V Cover (option) -V FG AC(L) AC(N) 15.11.5 0.5 49.5 4 Terminal cover 0.59 1.95 0.16 Point A:C102 1.5 22.6 0.89 Name plate 2-M3 Mounting hole PBA10F Tolerance : 1 0.04 0.5 Weight : 150g max (with cover : 180g max) 36 11 1.42 0.43 PCB Material/thickness : CEM3 / 1.6mm 0.06 Chassis material : Electric galvanizing steel board Dimensions in mm, = inches Mounting torque : 0.6N m(6.3kgf cm)max Screw tightening torque : M3 0.8N m(8.5kgf cm)max Please connect safety ground to the unit in 2-M3 holes. PBA/PBW-3 70.5 2.78 11.5 9.5 7.5 0.45 0.37 0.3 18 34.5 0.71 1.36 31 78 3.07 1.22 34.5 1.36