Additional Resources: Product Page 3D Model PCB Footprint date 11/24/2020 page 1 of 13 SERIES: PBO-1 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 1 W continuous power ultra-compact SIP package available in straight-pin and bent-pin configurations wide input voltage range over current and short circuit protections 3,000 Vac isolation 2 output output output ripple efficiency MODEL 1 voltage current power and noise min max max max typ (Vdc) (mA) (mA) (W) (mVp-p) (%) PBO-1-S5 5 10 200 1 120 66 PBO-1-S9 9 5.55 111 1 120 67 PBO-1-S12 12 4.15 83 1 120 70 PBO-1-S15 15 3.35 67 1 120 69 PBO-1-S24 24 2.1 42 1 120 68 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, see Application Circuit. 2. At 230 Vac input. 3. All specifications are measured at Ta=25C, humidity <75%, 115 or 230 Vac input voltage, and rated output load unless otherwise specified. PART NUMBER KEY PBO-1 - S XX - X Base Number Output Voltage Orientation blank = vertical B = right-angle cui.comAdditional Resources: Product Page 3D Model PCB Footprint CUI Inc SERIES: PBO-1 DESCRIPTION: AC-DC POWER SUPPLY date 11/24/2020 page 2 of 13 INPUT parameter conditions/description min typ max units 85 305 Vac voltage 70 430 Vdc frequency 47 63 Hz at 115 Vac 0.12 A current at 277 Vac 0.06 A at 115 Vac 9 A inrush current at 277 Vac 15 A 24 Vdc output models 0.3 W no load power consumption all other models 0.25 W OUTPUT parameter conditions/description min typ max units 5 Vdc output models 220 F capacitive load all other models 100 F 5 Vdc output models 8 % initial set point accuracy all other models 5 % line regulation at full load 1.5 % from 5~100% load load regulation 24 Vdc output models 6 % all other models 3 % hold-up time at 230 Vac 150 180 ms switching frequency 100 kHz temperature coefficient 0.15 %/C PROTECTIONS parameter conditions/description min typ max units over current protection auto recovery 110 500 % short circuit protection continuous, auto recovery SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 3,000 Vac certified to 62368: IEC/EN safety approvals certified to 60950: UL/cUL safety class Class II CISPR32/EN55032, Class A (recommended circuit 1,2,6) conducted emissions CISPR32/EN55032, Class B (recommedned circuit 3,4,5) CISPR32/EN55032, Class A (recommended circuit 1,2,6) radiated emissions CISPR32/EN55032, Class B (recommended circuit 3,4,5) ESD IEC/EN61000-4-2, contact 4 kV, perf. Criteria B radiated immunity IEC/EN61000-4-3, 10V/m, perf. Criteria A IEC/EN61000-4-4, 2 kV, (recommended circuit 1,2,3), perf. Criteria B EFT/burst IEC/EN61000-4-4, 4 kV, (recommended circuit 4,5,6), perf. Criteria B IEC/EN61000-4-5, line to line 1 kV, Class B (recommended circuit 1,2), perf. Criteria B IEC/EN61000-4-5, line to line 2 kV (recommended circuit 6), perf. Criteria B surge IEC/EN61000-4-5, line to line 1 kV/line to ground 2 kV (recommended circuit 3) perf. Criteria B IEC/EN61000-4-5, line to line 2 kV/line to ground 4 kV (recommended circuit 4,5) perf. Criteria B conducted immunity IEC/EN61000-4-6 Class A, 10 Vr.m.s, perf. Criteria A cui.com