USER GUIDE TB-9045 9310 Overhead Air Ionizer Installation, Operation and Maintenance Features and Components Hook Tabs Casing Front Grill Control Panel LED Power Indicator Back Grill Figure 1. SCS 9310 Overhead Air Ionizer Figure 2. Overhead Air Ionizer features and components Description overview The SCS 9310 Overhead Air Ionizer a self-contained, ionized air blower designed to neutralize electrostatic Power Switch charges from non-conductive objects (insulators) and isolated conductors. The SCS 9310 meets ANSI/ ESD S20.20 tested per ANSI/ESD STM3.1 and ESD Balance Adjust TR53. The ionizer is designed with a built-in automatic emitter points cleaner to periodically clean the emitter points therefore saving some manual work and time. The 3-fan construction ensures ionization over a wide workstation area. The SCS 9310 Overhead Air Ionizer is available in one Speed Selector model: Switch Item Power Adapter Input Figure 3. Overhead Air Ionizer controls 9310-NO 100-240 VAC The SCS 9310 Overhead Air Ionizer does not include a power cord. It must be purchased separately. Fuse Item Description Holder 770000 Power Cord, IEC C-13, North America DC Input Jack 770001 Power Cord, IEC C-13, UK 770002 Power Cord, IEC C-13, Europe Ground Terminal 770003 Power Cord, IEC C-13, China Packaging Figure 4. Overhead Air Ionizer features and components 1 Overhead Air Ionizer Unit (left side view) 1 Power Adapter, 100-240VAC Input, No Power Cord 1 Ground Wire 1 S-hook and Chain Set 1 Certificate of Calibration SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2015 DESCO INDUSTRIES, INC. TB-9045 Page 1 of 5 September 2015 Employee Owned3. Mounting on Workbench - Mounting brackets are designed for use on a variety of workbench frames such as: perforated steel angle metal framing and wire shelving. Install the Overhead Air Ionizer unit using the mounting tabs. Place a lock washer and flat washer on the bolt before inserting it into the mounting tab. Insert the bolt into the mounting tab, and then place another lock washer and flat washer on the bolt before placing the nut onto the bolt. Tighten the nut onto the bolt securing the unit to the frame. Figure 5. Power adapter (included) and SCS 770000 M5 Bolt North America Power Cord (not included) M5 Bolt and and Nut Nut Installation The Overhead Air Ionizer mounts easily in a suspended position above a workstation with the provided chain and hook. Place the unit above the worksurface and Workbench Workbench point it at the area or object to be neutralized. Cross Cross MembersMembers WARNING: The Overhead Air Ionizer is not designed to be used in explosive areas or flammable atmospheres. Figure 6. Mounting on a workbench Sparks from the fan motor or emitter points may cause ignition. Electrical Use the included AC/DC power adapter. The unit must The Overhead Air Ionizer cannot be used on table be grounded for proper operation. tops or bench tops. It must be installed using the mounting hardware provided. The safety of any system Grounding incorporating this equipment is the responsibility of the The Overhead Air Ionizer must be connected to ground assembler of the system. The ionizers performance through the GROUND Terminal on the side of the unit. is affected by its distance from the worksurface and Connect the included ground wire to a known electrical its fan speed. As the distance increases or fan speed ground point. Failure to connect the ground terminal decreases, the discharge time at the worksurface will may cause the unit to malfunction. increase. Operation Space Requirements Restricted space may prevent electrostatic elimination 1. Insert the AC/DC power adapter plug into an due to insufficient airflow. The Overhead Air Ionizer electrical outlet. Make certain that power line should be located 23 to 35 inches (600 to 900 mm) voltage is within the operating range of the AC/DC above the worksurface with the center fan directly above power adapter. The use of improper power line the critical area. There should be no cross flow of air voltages may impair operation or damage the unit. between the unit and the worksurface. Drafts from This will void the warranty. air conditioning or heating air outlets can affect the 2. The switch on the front of the unit turns the power performance of this device. on or off. The LED Power Indicator will light up Mounting when the unit is on. Use the slide switch to set the The Overhead Air Ionizer unit may be suspended using fan speed to low, medium or high. the S-hook and chain provided in the package. Chain and mounting hardware must have a minimum safe Maintenance working load of 33 lbs (15 kg). 1. When performing emitter needle maintenance, disconnect the Power Adapter AC plug from the 1. S-hooks, 6 pieces outlet. Do not connect or disconnect the power 2. Chain link, 12 inches plug with wet hands as doing so puts you at risk of electrical shock or injury. 2. Occasional cleaning of the case is required. Although the emitter points have a built-in automatic cleaner, a check is still necessary for any abnormality within the emitter points. Verification and adjustment may be required to keep the balance within the specification range. SCS - 926 JR Industrial Drive, Sanford, NC 27332 (919) 718-0000 Website: StaticControl.com 2015 DESCO INDUSTRIES, INC. TB-9045 Page 2 of 5 Employee Owned