Product Information

D2E146-HT59-02

D2E146-HT59-02 electronic component of ebm papst

Datasheet
CENTRIFUGAL BLOWER, 146MM, 230V

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 488.0615 ea
Line Total: USD 488.06

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 23 May to Wed. 29 May

MOQ : 1
Multiples : 1

Stock Image

D2E146-HT59-02
ebm papst

1 : USD 488.0615

     
Manufacturer
Product Category
Current Type
Bearing Type
Power Rating
Brand
Blower Type
Supply Voltage
Fan Frame Size
External Depth
Flow Rate - Metric
Flow Rate - Imperial
Power Connection Type
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
RER100-25/14 electronic component of ebm papst RER100-25/14

DC Motorized Impeller Centrifugal Ball Bearing 24V 12V to 28V 33.6CFM 47dB 100 X 32mm
Stock : 50

ODB600PT-12LB electronic component of Orion ODB600PT-12LB

Blowers & Centrifugal Fans DC Blower, Single Side Inlet, 120x31mm, 12VDC, 22CFM, 5.64W, 42dBA, 2300RPM, Dual Ball Bearing, 2x Wire Leads
Stock : 1

GB1205PKV1-8AY.GN electronic component of Sunon GB1205PKV1-8AY.GN

Blowers & Centrifugal Fans Blower, 50x20mm, 12VDC, 5.7CFM, 1.5W, 35dBA, Vapo Bearing, MagLev, Auto Restart
Stock : 1000

RL48-1914ML electronic component of ebm papst RL48-1914ML

Blowers & Centrifugal Fans DC Radial Blower, 76x76x27mm, 24VDC, 12.9CFM, 2.9W, 3500RPM, FlatPak Series
Stock : 0

04701.9-00 electronic component of Stego 04701.9-00

Heater; HGK 047; 20W; 120÷230V; IP44
Stock : 3

04710.0-00 electronic component of Stego 04710.0-00

Heater; HGK 047; 10W; 12÷30V; IP44
Stock : 1

06050.0-00 electronic component of Stego 06050.0-00

Heater; CSK 060; 30W; Uoper: 110÷265V; IP20; Urated: 120/240V
Stock : 9

06040.1-00 electronic component of Stego 06040.1-00

Heater; CSK 060; 10W; Uoper: 12÷30V; IP20; Urated: 24V
Stock : 1

04711.0-00 electronic component of Stego 04711.0-00

Heater; HGK 047; 20W; 12÷30V; IP44
Stock : 6

PHT050 electronic component of PLASTIM PHT050

Heater; 50W; 100÷250V; IP20; DIN rail; 138x70x59mm
Stock : 0

D2E146-HT59-02 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Mechanical movement 2 death or serious injury if the specified actions are not taken. 1.7 Emissions 2 Compliance with the instructions is imperative. 1.8 Hot surface 2 1.9 Transport 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Storage 2 death or serious injury if the specified actions are not taken. 2. INTENDED USE 3 Exercise extreme caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in 3.1 Product drawing 4 minor or moderate injury or damage to property if the specified 3.2 Nominal data 5 actions are not taken. 3.3 Data according to Commission Regulation (EU) 327/2011 5 3.4 Technical description 5 NOTE 3.5 Mounting data 5 A potentially harmful situation can occur and, if not avoided, can 3.6 Transport and storage conditions 6 lead to property damage. 4. CONNECTION AND STARTUP 6 1.2 Staff qualifications 4.1 Mechanical connection 6 The device may only be transported, unpacked, installed, operated, 4.2 Electrical connection 6 maintained and otherwise used by suitably qualified, trained and 4.3 Plug connection 7 authorized technical staff. 4.4 Connection diagram 8 Only authorized specialists are permitted to install the device, to carry 4.5 Checking connections 9 out a test run and to perform work on the electrical installation. 4.6 Switching on the device 9 4.7 Switching off the device 9 1.3 Basic safety rules 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 The safety hazards associated with the device must be assessed again CAUSES AND REMEDIES following installation in the final product. 5.1 Cleaning 10 Note the following when working on the device: 5.2 Safety inspection 10 Do not perform any modifications, additions or conversions on the 5.3 Disposal 10 device without the approval of ebm-papst. 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 5.2 Safety inspection. Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock When working on an electrically charged device, stand on a rubber mat. WARNING Live terminals and connections even with device switched off Electric shock Item no. 13481-5-9970 ENU Change 89168 Approved 2016-08-25 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsD2E146-HT59-02 Operating instructions Wait five minutes after disconnecting the voltage at all poles 1.7 Emissions before opening the device. WARNING CAUTION Depending on the installation and operating conditions, In the event of a fault, the rotor and the impeller will be the sound pressure level may exceed 70 dB(A). energized Risk of noise-induced hearing loss The rotor and the impeller have basic insulation. Take appropriate technical safety measures. Do not touch the rotor and impeller once installed. Protect operating personnel with appropriate safety CAUTION equipment such as hearing protection. The motor restarts automatically when operating voltage Also observe the requirements of local agencies. is applied, e.g. after a power failure. Risk of injury 1.8 Hot surface Keep out of the device s danger zone. CAUTION When working on the device, switch off the line voltage High temperature on motor housing and ensure that it cannot be switched back on. Risk of burns Wait until the device comes to a stop. Ensure sufficient protection against accidental contact. 1.5 Safety and protective features 1.9 Transport DANGER NOTE Protective device missing and protective device not Transporting the device functioning Transport the device in its original packaging only. Without a protective device there is a risk of serious injury, for Secure the device so it cannot slip, e.g. by using a instance when reaching into the device during operation. lashing strip. Operate the device only with a fixed protective device and guard grille. 1.10 Storage The fixed protective device must be able to withstand the Store the device, partially or fully assembled, in a dry place, kinetic energy of a fan blade that becomes detached at protected against the weather and free from vibration, in the original maximum speed. There must not be any gaps which it is packaging in a clean environment. possible to reach into with the fingers, for example. Protect the device against environmental effects and dirt until final The device is a built-in component. As the operator, you installation. are responsible for ensuring that the device is secured We recommend storing the device for no longer than one year in adequately. order to guarantee trouble-free operation and the longest possible Stop the device immediately if you notice a missing or service life. ineffective protective device. Even devices explicitly intended for outdoor use are to be stored as 1.6 Mechanical movement described prior to commissioning. Maintain the storage temperature, see DANGER Chapter 3.6 Transport and storage conditions. Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. Protect long hair with a cap. Item no. 13481-5-9970 ENU Change 89168 Approved 2016-08-25 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

FANS AND/OR BLOWERS, DC OR AC, axial OR radial OR crossflow type, having ANY one OR more of the following:
(a) sleeve OR ball OR magnetic bearings;
(c) AC operating voltage NOT less than 115 V and NOT greater than 240 V;
(d) maximum speed exceeding 1 000 RPM;
(e) diameter NOT greater than 300 mm;
(f) height NOT greater than 300 mm;
(g) length NOT greater than 300 mm,
with OR without filters
TC 17129205
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted