Product Information

R4D450-AK03-05

R4D450-AK03-05 electronic component of ebm papst

Datasheet
Blowers & Centrifugal Fans AC Backward Curved Motorized Impeller

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0 - WHS 1

MOQ : 1
Multiples : 1

Stock Image

R4D450-AK03-05
ebm papst

1 : USD 1317.9741
12 : USD 1305.7422
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Type
Current Type
Series
IP Rating
Brand
Product Type
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
RER100-25/14 electronic component of ebm papst RER100-25/14

DC Motorized Impeller Centrifugal Ball Bearing 24V 12V to 28V 33.6CFM 47dB 100 X 32mm
Stock : 50

ODB600PT-12LB electronic component of Orion ODB600PT-12LB

Blowers & Centrifugal Fans DC Blower, Single Side Inlet, 120x31mm, 12VDC, 22CFM, 5.64W, 42dBA, 2300RPM, Dual Ball Bearing, 2x Wire Leads
Stock : 1

GB1205PKV1-8AY.GN electronic component of Sunon GB1205PKV1-8AY.GN

Blowers & Centrifugal Fans Blower, 50x20mm, 12VDC, 5.7CFM, 1.5W, 35dBA, Vapo Bearing, MagLev, Auto Restart
Stock : 1000

RL48-1914ML electronic component of ebm papst RL48-1914ML

Blowers & Centrifugal Fans DC Radial Blower, 76x76x27mm, 24VDC, 12.9CFM, 2.9W, 3500RPM, FlatPak Series
Stock : 0

04701.9-00 electronic component of Stego 04701.9-00

Heater; HGK 047; 20W; 120÷230V; IP44
Stock : 3

04710.0-00 electronic component of Stego 04710.0-00

Heater; HGK 047; 10W; 12÷30V; IP44
Stock : 1

06050.0-00 electronic component of Stego 06050.0-00

Heater; CSK 060; 30W; Uoper: 110÷265V; IP20; Urated: 120/240V
Stock : 9

06040.1-00 electronic component of Stego 06040.1-00

Heater; CSK 060; 10W; Uoper: 12÷30V; IP20; Urated: 24V
Stock : 1

04711.0-00 electronic component of Stego 04711.0-00

Heater; HGK 047; 20W; 12÷30V; IP44
Stock : 6

PHT050 electronic component of PLASTIM PHT050

Heater; 50W; 100÷250V; IP20; DIN rail; 138x70x59mm
Stock : 0

R4D450-AK03-05 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Mechanical movement 2 WARNING 1.7 Emission 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Hot surface 2 could result in death or serious injury. Exercise extreme 1.9 Transport 2 caution while working. 1.10 Storage 2 CAUTION 1.11 Disposal 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 2. PROPER USE 3 NOTE 3. TECHNICAL DATA 4 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3.1 Product drawing 4 3.2 Nominal data 5 1.2 Staff qualification 3.3 Technical features 5 Only specialised electrical personnel may install the device, perform the 3.4 Mounting data 5 test run and work on the electrical system. Only trained and authorised specialist personnel are permitted to 3.5 Transport and storage conditions 5 transport, unpack, assemble, operate or maintain the device, or to use it 4. CONNECTION AND START-UP 6 in any other manner. 4.1 Connecting the mechanical system 6 1.3 Basic safety rules 4.2 Connecting the electrical system 6 Any safety hazards stemming from the device must be re-evaluated 4.3 Connection in terminal box 6 once it is installed in the end device. 4.4 Connection screen 8 Observe the following when working on the unit: 4.5 Opening of second screwed cable gland 9 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.6 Checking the connections 9 4.7 Switch on device 9 1.4 Electrical voltage 4.8 Switching off the device 9 Check the electrical equipment of the device at regular intervals, refer to chapter 5.2 Safety test. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 CAUSES AND REMEDIES Replace loose connections and defective cables immediately. 5.1 Cleaning 10 DANGER 5.2 Safety test 10 Electrical load on the device Risk of electric shock Stand on a rubber mat if you are working on an electrically charged device. WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 11001-5-9970 Revision 78922 Release 2012-10-16 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR4D450-AK03-05 Operating instructions CAUTION 1.7 Emission In the event of failure, there is electric voltage at the WARNING rotor and impeller Depending on the installation and operating conditions, The rotor and impeller are base insulated. a sound pressure level greater than 70 dB(A) may arise. Do not touch the rotor and impeller once they are installed. Danger of noise-induced hearing loss CAUTION Take appropriate technical safety measures. The motor restarts automatically when operating voltage Protect operating personnel with appropriate safety is applied, e.g. after a power failure. equipment, e.g. hearing protection. Danger of injury Also observe the requirements of local agencies. Keep out of the danger zone of the device. When working on the device, switch off the mains 1.8 Hot surface supply voltage and secure the latter from being switched on CAUTION again. High temperature at the motor housing Wait until the device stops. Danger of burn injuries Insert the brought-out thermal overload protector into the Ensure that sufficient protection against accidental contact is control circuit so that the cooled off motor does not switch on provided. independently after a fault. 1.9 Transport 1.5 Safety and protective functions NOTE DANGER Transport of device Missing safety device and non-functioning safety device Transport the device in its original packaging only. If there is no safety device, you could be seriously injured, for example by reaching into the running device with your hands. Secure the device so that it does not slip, e.g. by using a clamping strap. Operate the device only with a fixed and isolating safety protection and a fixed guard grille. The guard must withstand 1.10 Storage the kinetic energy of a fan blade detaching at maximum speed. Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment. The device is a built-in component. You, the owner/ operator, are responsible for providing adequate protection for Protect the device from environmental impacts and dirt until the final the device. installation. Shut down the device immediately if you detect a We recommend storing the device for a maximum up to one year to missing or ineffective protective feature. guarantee proper operation and longest possible service life. Even devices explicitly suited for outdoor use are to be stored as 1.6 Mechanical movement described prior to being commissioned. DANGER Maintain the storage temperature, see Rotating device chapter 3.5 Transport and storage conditions. Body parts that come into contact with the rotor and impeller Please make sure that all screwed cable glands are fitted with can be injured. dummy plugs. Secure the device against accidental contact. 1.11 Disposal Before working on the system/machine, wait until all parts have come to a standstill. When disposing of the device, please comply with all relevant requirements and regulations applicable in your country. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Do not wear any loose clothing or jewellery while working on rotating parts. Protect long hair by wearing a cap. Item no. 11001-5-9970 Revision 78922 Release 2012-10-16 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

FANS AND/OR BLOWERS, DC OR AC, axial OR radial OR crossflow type, having ANY one OR more of the following:
(a) sleeve OR ball OR magnetic bearings;
(c) AC operating voltage NOT less than 115 V and NOT greater than 240 V;
(d) maximum speed exceeding 1 000 RPM;
(e) diameter NOT greater than 300 mm;
(f) height NOT greater than 300 mm;
(g) length NOT greater than 300 mm,
with OR without filters
TC 17129205
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted