Thermal-Magnetic Circuit Breaker 2216-S Description 2216-S11 One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and auxiliary contacts. Meets the requirements of the circuit breaker standard EN 60934 (IEC 60934): S-type, TM. US patent number: US 9,246,266 B2 Typical applications 1 Protection of AC and DC control circuits in automation technology, with socket with socket for instance in process control, power plants, infrastructure, marine, 80plus 81plus machine building industry and rail engineering. Compliant with the relevant requirements of the railway standards DIN EN 50155, DIN EN 61373 and EN 45545 (detailed information upon request). Technical data For further details please see: www.e-t-a.de/ti e Ordering information Voltage rating AC 240 V (50/60 Hz) DC 50 V (1-pole) DC 80 V (2-pole) Type no. Current rating range 0.5...16 A 2216 thermal-magnetic circuit breaker Mounting method Auxiliary circuit AC 240 V, 0.5 A (VDE) S1 plug-in mounting AC 277 V, 0.5 A (UL) Number of poles DC 50 V, 1 A (VDE/UL) 1 1-pole Typical life 6,000 operations at 1 x IN 2 2-pole 3,000 operations at 1 x IN Additional function / accessories DC 80 V, 2-pole 0 without Main terminals Ambient temperature -30...60 C P1 blade terminals A6.3 x 0.8 with polarising Insulation co-ordination tooth (standard) (IEC 60664) 2,5 kV/2 Characteristic curve re-inforced insulation in operating area F1 therm. 1.01-1.4 x I magn. 2-4 x I (only for DC) N N Dielectric strength F2 therm. 1.01-1.4 x I magn. 3-6 x I AC / 4-8 I DC N N N operating area test voltage AC 3,000 V M1 therm. 1.01-1.4 x I magn. 6-12 x I AC / 8-15 I DC N N N main/aux. circuit test voltage AC 1,500 V Auxiliary contacts Open aux. circuit AC 1,000 V S1 with auxiliary contact Insulation resistance > 100 M (DC 500 V) Auxiliary contact function 1 change-over Interrupting capacity I AC 240 V 1-pole 300 A cn Auxiliary contact terminals DC 32 V 1-pole 1500 A 1 blade terminals A6.3 x 0.8 DC 50 V 1-pole 600 A with polarising tooth (standard) AC 240 V 2-pole 400 A Voltage rating DC 32 V 2-pole 1500 A A AC 277 V, DC 80 V DC 80 V 2-pole 600 A Current ratings Interrupting capacity AC 277 V 1,000 A 0.5....16 A (UL 1077) DC 50 V 1-pole 1,000 A DC 80 V 2-pole 1,000 A 2216 - S1 1 0 - P1 F1- S1 1 1 - A-16A Ordering example Degree of protection operating area IP30 Please be informed that we have minimum ordering quantities to be observed. (IEC 60529) terminal area IP00 Vibration curve F1: 5 g (57-500 Hz), 0.38 mm (10-57 Hz) curves F2, M1: 8 g (57-500 Hz) 0.61 mm (10-57 Hz) Standard current ratings and typical internal resistance values test to IEC 60068-2-6, test Fc, 10 frequency cycles per axis Current rating Internal Current rating Internal Shock (A) resistance () (A) resistance () curve F1: 15 g (11 ms) for shock direction 1-6 curves F2, M1: 30 g (11 ms) for shock direction 1-6 0.5 5.0 6 0.05 test to IEC 60068-2-27, test Ea Corrosion 96 hrs in 5 % salt mist, 1 1.1 8 0.02 test to IEC 60068-2-11, test Ka 2 0.3 10 0.02 Humidity 240 hrs in 95 % RH, test to IEC 60068-2-78, test Cab 3 0.14 12 0.02 Mass approx. 25 g (per pole with aux. contact) 4 0.09 15 0.02 5 0.06 16 0.02 2010 www.e-t-a.de 1Thermal-Magnetic Circuit Breaker 2216-S Approvals Dimensions 2216-S11 with socket 80plus 90 Authority Standard Voltage Current ratings 3.54 ratings 45 1.77 CSA C22.2 No. 235 AC 277 V 0.1...16 A (1-, 2-pole) DC 50 V 0.1...16 A (1-pole) DC 80 V 0.1...16 A (2-pole) Operating area VDE IEC / EN 60934 AC 240 V 0.1...16 A (1-, 2-pole) DC 50 V 0.1...16 A (1-pole) DC 80 V 0.1...16 A (2-pole) UL UL 1077 AC 277 V 0.1...16 A (1-, 2-pole) C22.2 No 235 DC 50 V 0.1...16 A (1-pole) 1 DC 80 V 0.1...16 A (2-pole) DNV Rules for classification AC 240 V 0.1...16 A (1-, 2-pole) GL DNVGL-CG 0339 DC 50 V 0.1...16 A (1-, 2-pole) DC 80 V 0.1...16 A (2-pole) 12.3 CQC GB/T 17701 AC 240 V 0.1...16 A (1-, 2-pole) .484 DC 50 V 0.1...16 A (1-, 2-pole) optional labels DC 80 V 0.1...16 A (2-pole) UL *) UL 60947-4-1A AC 277 V 0.1...10 A (1-, 2-pole) C22.2 No 60947-4-1 DC 50 V 0.1...16 A (1-pole) DC 80 V 0.1...10 A (2-pole) *) cULus (listed) using with socket 80PLUS or socket 81PLUS Dimensions 2216-S11 with socket 81plus Schematic diagram 90 3.54 line 45 0I 1.77 1 11 12 14 Operating area > I 2 Dimensions 2216-S1 max. 24.6 12.3 max969 .484 (12.3) (12.3) 45 45 45 max. 12.3 optional labels max. 12.3 1.77 1.77 max484 .484 .484 1.77 max484 Operating area Operating area Operating area Envelope size to DIN 43880 The envelope size of type 2216-S with socket 80plus or 81plus complies with the requirements of DIN 43880 (built-in equipment for electrical installation). 11211142 11211142 11211142 12,5 17,5 Optional labels 1-pole 2-pole Optional labels optional labels Pole 2 Shock directions Pole 1 5 6 4 3 2 70 70 1 Envelope size to DIN 43880 (Size 1) Envelope size 2216-S with socket 80plus or 81plus 2 www.e-t-a.de 2010 52 2.05 52 2.05 52 2.06 51.2 2.02 51.2 2.02 51.2 2.02 70 70 90 2.76 2.76 90 44 33.2 1.30 1.73 69 69 2.72 2.71