ECE The Name You Can Trust RADIAL LEADED PTC E175689 Pending EX/EU MODEL FEATURES z Solid state, Radial leaded product ideal for up to 120VAC/VDC z Operation current: 0.10A~3.75A z Maximum Voltage: 120VAC/VDC z Maximum Interrupt Voltage: 135VAC/VDC z Temperature range: -40 to 85 z Cured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirement z Bulk packing, tape and reel available on most models APPLICATIONS z Line voltage power supply z Transformer and appliances product PART NUMBERING SYSTEM ERF XX XXX XX X X X Z: RoHS Compliant Special number: 0: Standard product Packing type: 0: bulk 2: tape & reel Voltage rating: V1: 120V Current rating: 135: 1.35A Model: EX: (Disc type) EU: (Rectangle type) Product Name: Resettable Fuse Marking system ECE EXCEL CELL ELECTRONIC LOGO ECE EX EX135 Current Rating 09AB Model RoHS Compliant Example Date Code/Lot Number *If the current rating is under 1Amp their will be no ECE logo shown on the body. NOTE: Specifications subject to change without prior notice. 1 For the latest product information, Please visit our website at www.ece.com.tw ECE The Name You Can Trust Electrical characteristics(23) Resistance Hold Trip Max. Time Max. Max. Oper. Max. Int. Typical Tolerance Part Current Current to trip Current Voltage Voltage Power RMIN R1MAX Number IH, A IT, A at 5x IH IMAX, A VMAX, VAC/DC VI-MAX, VAC/DC Pd, W EX010-V1 0.10 0.20 10.0 2.0 120 135 0.84 3.00 7.50 EX017-V1 0.17 0.34 10.0 2.0 120 135 0.84 2.00 7.00 EX020-V1 0.20 0.40 9.0 2.0 120 135 1.08 1.83 4.40 EX025-V1 0.25 0.50 7.5 3.0 120 135 1.08 1.25 3.00 EX030-V1 0.30 0.60 8.5 3.0 120 135 1.44 0.88 2.10 EX040-V1 0.40 0.80 6.5 3.0 120 135 1.44 0.55 1.29 EX050-V1 0.50 1.00 6.0 3.0 120 135 1.56 0.50 1.17 EX065-V1 0.65 1.30 5.7 5.0 120 135 1.68 0.31 0.72 EX075-V1 0.75 1.50 6.3 5.0 120 135 1.80 0.25 0.60 EX090-V1 0.90 1.80 7.2 5.0 120 135 1.80 0.20 0.47 EX110-V1 1.10 2.20 8.2 8.0 120 135 2.28 0.15 0.38 EX135-V1 1.35 2.70 9.6 10.0 120 135 2.64 0.12 0.30 EX160-V1 1.60 3.20 11.4 12.0 120 135 3.12 0.09 0.22 EX185-V1 1.85 3.70 12.6 12.0. 120 135 3.36 0.08 0.19 EX250-V1 2.50 5.00 15.6 15.0 120 135 4.44 0.05 0.13 EX300-V1 3.00 6.00 19.8 17.0 120 135 4.56 0.04 0.10 EX375-V1 3.75 7.50 24.0 20.0 120 135 4.80 0.03 0.08 EU075-V1 0.75 1.50 15.0 7.5 120 135 2.64 0.25 0.69 EU100-V1 1.00 2.00 15.0 10.0 120 135 2.64 0.18 0.47 EU125-V1 1.25 2.50 20.0 12.5 120 135 2.88 0.11 0.33 EU135-V1 1.35 2.70 20.0 13.5 120 135 3.12 0.11 0.30 EU200-V1 2.00 4.20 36.0 20.0 120 135 4.32 0.08 0.21 IH=Hold current-maximum current at which the device will not trip at 23 still air. IT=Trip current-minimum current at which the device will always trip at 23 still air. V MAX=Maximum voltage device can withstand without damage at its rated current. I MAX= Maximum fault current device can withstand without damage at rated voltage (V max). Pd=Typical power dissipated from device when in the tripped state in 23 still air environment. RMIN=Minimum device resistance at 23. R1MAX=Maximum device resistance at 23 1 hour after tripping . NOTE: Specifications subject to change without prior notice. 2 For the latest product information, Please visit our website at www.ece.com.tw