Product Information

SIMPLY MAX P01

SIMPLY MAX P01 electronic component of F&F

Datasheet
Telemetry; PLC MAX; IP20; 230VAC; relay; DIN; Temp: -10÷50°C; 3W

Manufacturer: F&F
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 187.8857 ea
Line Total: USD 187.89

3 - Global Stock
Ships to you between
Fri. 24 May to Thu. 30 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
3 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1
1 : USD 183.729

     
Manufacturer
Product Category
Series
Mounting
Kind Of Output 1
Electrical Connection
Ip Rating
Type Of Module
Number Of Outputs
Power Consumption
Supply Voltage
Number Of Inputs
Operating Temperature
Dimensions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
AT-2U electronic component of F&F AT-2U

Converter: temperature; 9÷30VDC; Kind of outputs:0÷10V; -20÷50°C
Stock : 1

BIS-410 230V electronic component of F&F BIS-410 230V

Relay: installation; bistable; NO; Mounting: in mounting box; 16A
Stock : 0

BIS-419 230V electronic component of F&F BIS-419 230V

Relay: installation; bistable; DPDT; Mounting: DIN; 16A; -25÷50°C
Stock : 1

BIS-419I 230V electronic component of F&F BIS-419I 230V

Relay: installation; bistable, inrush; NO x2; Mounting: DIN; 16A
Stock : 0

CKF-337 electronic component of F&F CKF-337

Module: voltage monitoring relay; DIN; SPDT; OUT1:250VAC/8A; IP20
Stock : 4

BIS-409 230V electronic component of F&F BIS-409 230V

Relay: installation; bistable; NO x2; Mounting: in mounting box
Stock : 1

BIS-412I 230V electronic component of F&F BIS-412I 230V

Relay: installation; bistable, inrush; SPDT; Mounting: DIN; 16A
Stock : 1

AS-221T electronic component of F&F AS-221T

Staircase timer; IP20; 230VAC; DIN; 10A; -20÷50°C; Range:30s÷10min
Stock : 0

AS-223 electronic component of F&F AS-223

Staircase timer; IP20; 230VAC; DIN; 10A; -20÷50°C; Range:30s÷10min
Stock : 0

AS-225D electronic component of F&F AS-225D

Staircase timer; IP20; 9÷30VDC; DIN; 24A; -15÷50°C; Ch: 12
Stock : 1

Image Description
MIKROE-2523 electronic component of MikroElektronika MIKROE-2523

Power Management IC Development Tools AC Current click
Stock : 10

MCP1252DM-BKLT electronic component of Microchip MCP1252DM-BKLT

Power Management IC Development Tools MCP1252 Charge Pump Backlight Demo Brd
Stock : 1

Hot MIKROE-1198 electronic component of MikroElektronika MIKROE-1198

Power Management IC Development Tools VOLT SMART USB LIPO BATTERY CHARGER
Stock : 1

BOB-11722 electronic component of SparkFun BOB-11722

Power Management IC Development Tools SparkFun Rotary Encoder Breakout - Illuminated (RG/RGB)
Stock : 10

ADM00468 electronic component of Microchip ADM00468

MCP1710 1 - Single Channels per IC Positive Fixed Linear Voltage Regulator Evaluation Board
Stock : 1

STEVAL-ISA166V1 electronic component of STMicroelectronics STEVAL-ISA166V1

Power Management IC Development Tools Evaluation board: SRK2001 adaptive synchronous rectification controller for LLC resonant converters with STP77N6F6
Stock : 1

STEVAL-ISA077V2 electronic component of STMicroelectronics STEVAL-ISA077V2

Power Management IC Development Tools L6920D Synch BRD REC Step-Up Conv
Stock : 1

MIKROE-3032 electronic component of MikroElektronika MIKROE-3032

Power Management IC Development Tools Brushless 5 click
Stock : 0

105990027 electronic component of Seeed Studio 105990027

Power Management IC Development Tools Easy Driver stepper motor driver V4.5
Stock : 0

MIKROE-3844 electronic component of MikroElektronika MIKROE-3844

Power Management IC Development Tools Single Cell Click
Stock : 0

FUNCTIONING F&F Filipowski sp. j. Konstantynowska 79/81 95-200 Pabianice Relay can operate with any GSM 900/1800 mobile operator (no simlock). In tel/fax +48 42 2152383 2270971 POLAND order to operate properly valid SIM card have to be inserted. The relay has http:/www.fif.com.pl e-mail: fif fif.com.pl two relay outputs for switching ON /OFF of controlled receivers and two high GSM REMOTE CONTROL SIMply MAX voltage inputs for messages about state changing of controlled receivers. All commands, responses and alerts exchange between mobile phone and relay RELAY P01 is carried out using SMS messages. WARRANTY. The F&F products are covered by the 24 months warranty from I/O DESCRIPTION date of purchase. Effective only with proof of purchase. Contact your dealer or L N directly from us. For more information on 5 input no. 1 the procedures for filing complaints on 11 12 6 input no. 2 www.fif.com.pl/reklamacje 5 9 0 8 3 1 2 5 9 6 7 4 5 5 9 0 8 3 1 2 5 9 6 9 4 3 7-8 output no.1 IN1 IN2 L 5 6 L (separated contact) Do not dispose of this device in the trash along with other waste According to the Law on Waste, electro coming from households free of charge and can 9-10 output no. 2 give any amount to up to that end point of collection, as well as to store the (separated contact) occasion of the purchase of new equipment (in accordance with the principle OUT1 OUT2 of old-for-new, regardless of brand). Electro thrown in the trash or abandoned 11-12 supply in nature, pose a threat to the environment and human health. 7 8 9 10 COMMANDS AND MESSAGES SETTING PERMANENT OUTPUTS STATES PURPOSE OUT1 ON - switch ON output 1 P01 relay with built-in GSM communicator is used to remote control via OUT2 ON - switch ON output 2 mobile phone. It allows an easy way to manage and monitor outputs status OUT1 OFF - switch OFF output 1 devices connected to the inputs and outputs of the relay. OUT2 OFF - switch OFF output 2 TEMPORARY SWITCHING of OUTPUT OUT1 ON S x - temporary switching output 1 at time x, where x is in the SMS range 1 300sec IN OUT2 ON S x - output switch no.2 time to time x, where x is in the range 1 2 3 4 5 6 1 300sec F& F POW STAT OUT1 ON M x - temporary switching output 1 at time x, where xi s in the GSM range 1 600min SIM SIM ply MAX P01 OUT2 ON M x - temporary switching output 1 at time x, where x is in the 7 8 9 10 11 12 range 1 600min Example: OUT OUT1ON S 30 - switching output 1 time for 30 seconds. OUTON M10 - switching out one time for 10 minutes. SMS ALERTS ON MOBILE ABOUT ACTUATION OF INPUT AUTOMATIC REPLY IN1 ON - high state (voltage) Input 1 The optional auto-reply on the phone the user with a message that reaches IN1 OFF - low state (no voltage) Input 1 and adoption of SMS. IN2 ON - high state (voltage) Input 2 ANSW - request an automatic response. The word served after the main IN2 OFF - low state (no voltage) Input 2 command. the answer is and confirmation of the status of inputs, outputs and functions. Example REQUEST ABOUT STATE OF ENTRY AND EXIT Command: OUT2ON ANSW. Content response: OK OUT2 ON IN1 - query about the state of the input 1(ans: IN1 ON / IN1 OFF) Command: PASS ON 1234 ANSW. Content response: OK PASS ON 1234 IN2 - query about the state of the input 2(ans: IN2 ON / IN2 OFF) Command: IN1 +48123456789 ANSW. Content response: OK IN1 +48123456789 OUT1 - query about the state of output 1(ans: OUT1 ON / OUT1 OFF) OUT2 - queryabout the state of output 2 (ans: OUT2 ON / OUT2 OFF) REDEFINITION OF INPUTS, OUTPUTS AND STATES NAMES PASSWORD (48 digits) In order to simplify SMS messages used in communication with relay user can If you are working with a password option command must precede add own names for all inputs, outputs and states. password, eg 1234 OUT1 ON. Request for input or output state we create by adding to the defined name of SMS configuration commands: a question mark. PASS ON - with this option with password Furthermore only ON and OFF commands will be accepted even if other PASS OFF - disable the password names for states were set. PASS ON xxxxxxxx - set or change the password Redefinitions of names used in SMS Messages: xxxxxxxxxx - Enter the number of passwords, e.g. 12345678 TEXT IN1 <input1 name> <state ON> <state OFF> TEXT IN2 <input2 name> <state ON> <state OFF> INPUTS CONFIGURATION TEXT OUT1 <output1 name> <state ON> <state OFF> Set the phone number to which you want to send the message. TEXT OUT2 <output2 name> <state ON> <state OFF> IN1 xxxxxxxxx ON - notification fixed phonenumber with high (voltage) Alternative names can be 10 characters long and cannot have spaces. Input no. 1 Examples IN1 xxxxxxxxx OFF - notice the fixed phonenumber at a low state (no INPUT 1 voltage) on the input no. 1 Definition: TEXT IN1 GATE OPEN CLOSE IN1 xxxxxxxxx NF - notice the fixed phonenumber about low and high Question: GATE ststus of input no 1 Answer: GATE OPEN IN2 xxxxxxxxx ON - notification fixed phonenumber with high (voltage) OUTPUT 2 Definition: TEXT OUT1 pump 2 turnedON turnedOFF Input no. 2 Question: pump IN2 xxxxxxxxx OFF - notice the fixed phonenumber at a low state (no Answer: pump turnedOFF voltage) on the input 2 Commends: pump 2 ON IN2 xxxxxxxxx NF - notice the fixed phonenumber about low and high ststus of input no 2 Warrning Note that even if user redefine names relay will accept default xxxxxxxxxx - provide a phone number with a prefix, such as commands. +48123456789 SIMExample AUTOMATIC REPLY CONFIG: The optional auto-reply on the phone the user with a message that reaches IN1 +48123456789 NF and adoption of SMS. IN2 +48987654321 ON ANSW - request an automatic response. The word served after the main MEMORY OFF command. the answer is and confirmation of the status of inputs, outputs PASS ON 1234 and functions. LANGUAGE example The option to select the language for automatic SMS notification. Command: OUT2 ON ANS. Content response: OK OUT2 ON LANG EN - english Command: PASS ON 1234 ANSW. Content response: OK PASS ON 1234 Command: IN1 +48123456789 ANSW. Content response: OK IN1 +48123456789 NOTATION Relay recognizes commands in lowercase and uppercase letters. STATUS SIM CARD USSD Also in the case of mixed character command. Execution of maintenance tasks, such as activation and deactivation of Example services, check the status and recharge of account, etc., using the operator Proper record of commands: OUT1ON / out1on / Out1oN service USSD (Unstructured Supplementary Service Data). USSD <USSD code> In response to a user s phone will come SMS with the response operator, Between the command words combined to put a space. The which would be consistent with the information given USSD command, such otherwise, the command will be confusing for the relay and will be as the current charge state and the expiry date (the content and format of the ignored. notification depends on the operator). Example OUT1ON M 10 - correctly Example OUT1ON M10 - incorrectly USSD *111 state and the expiry date - space USSD *123*12345678909876 recharge of account Abowe there are examples of commands USSD codes. In fact, they are determined individually by mobile network operators. LED INDICATION MEMORY OF OUTPUT * U - switched power relay Automatic restoration the status of outputs after the disappearance and * STAT blink 0.5s with period 0,1s, GSM off - there is no cardSIM when power is restored (restart). * STAT flashes 0.25s with period of 0.5s, GSM off - no SIM cardlogs on to the MEMORY ON- on the option. network operator. With an active SIM card with a PIN code. MEMORY ON -disable option. Deactivate the PIN code for the SIM card used. * STAT flashes 0.5s with period of 1.0s, GSM lights on - searchGSM network. CONFIGURATION PARAMETERS * STAT lights on / flashing, GSM blinking - Normal operation: Obtaining configuration information via SMS commands for phone user. 1. Signalling power range by the number of LED flashes GSM: 0.15s with CONFIG - query about configuration parameters example: period 6s (from 1 to 5 flashes) ASSEMBLY AND CONNECTION 2. Communication signals by the number of LED flashes STAT: 0.5s with period 6s (1 blink - SMS input, two blinks -SMS output, three blinks - error 1 Turn off the power. SMS output, 6 blinks- Voice connection) 2 Put the relay on the rail in the switchboard. * STAT is off, GSM off - GSM module is not working. Suspension of work 3 Connect the power supply to the relay: L to terminal 11 N to terminal 12 function or permanent fault. Make a restart of controller. 4 Screw the supplied antenna to the transmitter and attach itto the ground outside the switchgear, the site of GSM. 5 In place of the SIM port thin tool (eg a screwdriver)press the yellow button. WIRING DIAGRAM Remove the tray, load the SIM card and inserted into the port. Example of connecting the input signal to the input no 1 ( joint 5 ) for the 6 Connect the receiver and control input signals in accordance with the description of the I / O connections and examples of implementation. notification of activation. 7 Switch on the power supply. TECHNICAL DATA L N R supply 230V AC inputs number 2 P01 voltage tolerance 160260V AC relay outputs WE1 number 2 5 type 1NO nominal voltage 230V AC current load <8A Example of connecting the receiver to the controlled output 1 forthe ports SIM power consumption remote control. standby mode 1,3W with GSM comunnication <3W P01 working temperature -1050C connection screw terminals dimensions 3 modules (52mm) fixing on the rail TH-35 7 8 GSM antenna connector SMA / dim. 20x100m / lenght 2,5m N L R SW.VER.01.06 D131121/131127

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted