Product Information

SONDA RT

SONDA RT electronic component of F&F

Datasheet
Sensor: temperature; KTY81-210; Body dim: Ø5x20mm; -50÷65°C

Manufacturer: F&F
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 15.99 ea
Line Total: USD 15.99

13 - Global Stock
Ships to you between
Fri. 05 Apr to Thu. 11 Apr
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
8 - Global Stock


Ships to you between Fri. 05 Apr to Thu. 11 Apr

MOQ : 1
Multiples : 1
1 : USD 16.575
2 : USD 13.728
4 : USD 12.974

     
Manufacturer
Product Category
Kind Of Temperature Sensor
Leads
Related Items
Type Of Sensor
Cable Length
Operating Temperature
Body Dimensions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
AT-2U electronic component of F&F AT-2U

Converter: temperature; 9÷30VDC; Kind of outputs:0÷10V; -20÷50°C
Stock : 1

BIS-410 230V electronic component of F&F BIS-410 230V

Relay: installation; bistable; NO; Mounting: in mounting box; 16A
Stock : 0

BIS-419 230V electronic component of F&F BIS-419 230V

Relay: installation; bistable; DPDT; Mounting: DIN; 16A; -25÷50°C
Stock : 1

BIS-419I 230V electronic component of F&F BIS-419I 230V

Relay: installation; bistable, inrush; NO x2; Mounting: DIN; 16A
Stock : 0

CKF-337 electronic component of F&F CKF-337

Module: voltage monitoring relay; DIN; SPDT; OUT1:250VAC/8A; IP20
Stock : 12

BIS-409 230V electronic component of F&F BIS-409 230V

Relay: installation; bistable; NO x2; Mounting: in mounting box
Stock : 1

BIS-412I 230V electronic component of F&F BIS-412I 230V

Relay: installation; bistable, inrush; SPDT; Mounting: DIN; 16A
Stock : 1

AS-221T electronic component of F&F AS-221T

Staircase timer; IP20; 230VAC; DIN; 10A; -20÷50°C; Range:30s÷10min
Stock : 0

AS-223 electronic component of F&F AS-223

Staircase timer; IP20; 230VAC; DIN; 10A; -20÷50°C; Range:30s÷10min
Stock : 0

AS-225D electronic component of F&F AS-225D

Staircase timer; IP20; 9÷30VDC; DIN; 24A; -15÷50°C; Ch: 12
Stock : 1

Image Description
ZAD-ECO-V2 electronic component of Cobi ZAD-ECO-V2

Module: process analogue calibrator; Vol.output:0÷10V; panel
Stock : 8

TK4H-14SC electronic component of Autonics TK4H-14SC

Module: regulator; temperature; SSR; SSR, analogue; on panel; IP65
Stock : 1

TX4S-14R electronic component of Autonics TX4S-14R

Module: regulator; temperature; SPST-NO; SPST-NO; on panel; IP50
Stock : 20

TC4Y-12R electronic component of Autonics TC4Y-12R

Module: regulator; temperature; SPST-NO; SSR; on panel; 250VAC/3A
Stock : 5

TP-1W electronic component of Etron TP-1W

Module: regulator; NTC; temperature; NO, relay; for wall mounting
Stock : 1

TF31-31H electronic component of Autonics TF31-31H

Module: regulator; NTC, RTD; temperature; SPDT; SPST-NO; panel
Stock : 1

TFD-3 electronic component of Autonics TFD-3

Module: display; Body dim:31.5x52x12mm; Cable len:3m
Stock : 3

TX4M-B4R electronic component of Autonics TX4M-B4R

Module: regulator; temperature; SPST-NO; SPST-NO; on panel; IP50
Stock : 2

AR621/S electronic component of Apar AR621/S

Module: regulator; temperature; SSR; panel; 11VDC/25mA NPN; 0÷50°C
Stock : 1

E33NDRR-BVVIWBE electronic component of Ascon E33NDRR-BVVIWBE

Module: regulator; NTC; temperature; SPST-NO; OUT 2:SPDT; on panel
Stock : 13

Optionally, the controller carries sound and visual signaling exceed the ul. Konstantynowska 79/81 95-200 Pabianice temperature measured at 5 C above the set (eg in case of failure of tel/fax 48 42 2270971 POLAND the controlled device, orglue the contacts of the regulator. e-mail: fif fif.com.pl WORKS MODES RT-826 -H- - HEATING mode By the time you reach the desired temperature relay joint is closed TEMPERATURE REGULATOR (heating device aswitched). Achieving the desired temperature to open the joint (the heating unit off). The drop in temperature causes the hysteresis value again close the tightness. Excess temperature, measured at 5 C above the set temperature is indicated by a rapid pulse digits (measured value) on the display. 5 9 0 8 3 1 2 5 9 4 5 1 2 > T www.fif.com.pl hist F&F products are covered by an 24 months warranty from date of purchase PURPOSE The temperature controller is used to control heating and ventilation equipment to maintain a constant temperature. -H6- - HEATING mode with alarm function +5C As the mode -H-. In cases where the temperature measured at 5 C REGULATOR FUNCTIONS above the set alarm will be heard. Optionally you can connect an * Work mode: heating / cooling. external light signaling acting jointly with buzzer. *Correction idications of 9 C. * Alarm temperature exceeded 5 C from t hesetpoint . * The projection of the current measured temperature. AL FUNCTIONING (T+5) Regulator, depending on the selected mode of operation, is designed T to control heating or cooling appliances. The operating mode is hist indicated on the display value of current measured temperature. Closing the control contact (switch on-controlled devices) is indicated by a red LED . Setting the desired temperature and hysteresis and mode of operation is done by using two buttons on the front of the AL controller. Exceeding the temperature by 5 C from the set pulse is indicated by the display. PROGRAMMING -o- - HEATING mode By the time you reach the desired temperature relay joint is closed SETTING WORK MODE and HYSTERESIS (cooling switched). Achieving the desired temperature to open the joint (cooling off). Increasing the temperature of the hysteresis value will re- Work Mode close the tightness. The drop in temperature measured at 5 C below the hysteresis value is indicated by a rapid pulse digits (measured In the working mode at the same time, press briefly (<1 sec.) + value) on the display. and - buttons. On the display will show - - - (level of selection mode and hysteresis settings.) By buttons + / - to select the setting mode (possible symbols:-H,-H6-,-O-,-O6-). + And - buttons simultaneously press and hold until the pulsation T of the symbol on the display (> 5 sec.). Release the buttons. The hist display stops flashing. By buttons + / - to select the operating mode. After 5 secs. inactivity is followed by a return to automatic level adjustment mode selection and hysteresis (- - -). Buttons + and - simultaneously press a short time (<1sec.). The regulator returns to operating mode (temperature measured reports) and automaticly will start work with the new settings. -o6-- COOLING mode with alarm function -5C As a preliminary -O- mode. If the measured temperature falls by 5 C below the hysteresis value alarm will be heard. Optionally you can HYSTERESIS connect an external light signaling acting jointly with buzzer. In the working mode at the same time, press briefly (<1 sec.) + and - buttons on the display will show - - - (level of selection mode and hysteresis settings.) By buttons + / - to select the setting hysteresis (symbol, k0i such as the previously set hysteresis) T + And - buttons simultaneously press and hold until the pulsation of the symbol on the display (> 5 sec.). Release the buttons. The hist display stops flashing. Press the + / - buttons to make setting the hysteresis value. After 5 sec. inactivity is followed by a return to AL (T-hist-5) automatic level adjustment mode selection and hysteresis (- - -). Buttons + and - simultaneously press a short time (<1sec.). AL Theregulator returns to operating mode (temperature measured reports ) and automaticly will start work with the new settings.TEMPERATURE SETTING AND VIEWING TECHNICAL DATA supply 230V AC Preview current load <16A In work mode, press briefly (<1 sec.) press + or -. The display shows the joint 1Z value of the set temperature. After 5 sec. regulator returns to operating o range of regulation temperature. -25130 C mode (measured temperature readings). o hysteresis setting range 130 C o setting precision 1 C Setting o precision 1 C In work mode, press briefly (<1 sec.) press + or -. The display shows the temperature sensor KTY 81-210 value of the set temperature. By buttons + / - to set the new value of temperature. After 5 sec. regulator returns to idle operating mode sound signaling resonant frequency 2,4kHz (measured temperature readings) and automaticly will start work volume 80dB with the new settings. visual signal output open collector (OC) voltage 1224V DC CORRECTION OF REFERENCE TEMPERATURE SETTING current <30mA In the working mode at the same time press the + and - buttons and to display 3sectional LED 59mm hold until the appears -8 - on the display. Release the button. The signal switching contact LED red display will show the previously set correction value, such as O2. By temperature probe o buttons + / - to set the new value of correction (range -5 5 C). After 5 -2560 C RT o sec. regulator returns to idle operating mode (measured temperature 60130 C RT823 readings) and automaticly will start work with the new settings. power consumption 1,1W working temperature -2550C 2 connections screw terminals 2,5mm dimensions 2 modules (35mm) ASSEMBLY fixing on rail TH-35 1. Take OFF the power. 2. Regulator put on the rail in the switchgearbox. Dedicated temperature probe F&F 3. Controlled receiver connect in line to joints 1-2 (separate joint of mark RT regulator). temperature sensor KTY81-210 4. Install the temperature probe at the measure temperature place and sensor dimensions 5 h=20mm connected to the regulator. Note that the sensor was not close to the sensor isolation heat shrink heating or ventilation. If necessary you can extend the probe cable 2 cable OMY 2x0,34mm l=2,5m 10m. For longer cable may experience failures in the relay. 5. Optionally, the terminal 7-8 (output AL) connected in line a visual mark RT823 signaling device (lamp). temperature sensor KTY81-210 6. Take ON the power. sensor dimensions 8 h=40mm 7. Make settings of regulator program . sensor isolation metal bushing 2 cable refractory SIHF 2x05mm l=2,5m WIRING DIAGRAM L N 3 4 2 1 5 KTY81-210 6 7 - 1224V DC OC AL <30mA 8 + INPUTS/OUTPUTS description 1-2 normally open contact NO (normaly open) 3-4 supply 230V 5-6 temperature probe inputs 7-8 output AL alarm light signaling as open collector A110518

Tariff Desc

8542.3 - Electronic integrated circuits:
8542.31.00 -- Processors and controllers, whether or not combined with memories, converters, logic circuits, amplifiers, clock and timing circuits, or other circuits
Monolithic integrated circuits:
.Digital:
61 No ..Linear/analogue and peripheral integrated circuits, timers, voltage regulators, A/D and D/A converters, telecommunication and modem integrated circuits, other than board level products
62 No ..Other
63 No Hybrid integrated circuits
64 No Multichip integrated circuits

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted