Product Information

I40S-EL3X/3PK

I40S-EL3X/3PK electronic component of Fluke

Datasheet
Clamp Multimeters & Accessories FLUKE-17XX I40S-EL CLAMP-ON CURRENT TRANSFORMER, 3 PACK

Manufacturer: Fluke
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 885.9257 ea
Line Total: USD 885.93

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Wed. 22 May to Tue. 28 May

MOQ : 1
Multiples : 1
1 : USD 885.9257

0 - WHS 2


Ships to you between Tue. 28 May to Thu. 30 May


Multiples : 1

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1273185 electronic component of Fluke 1273185

HEAVY DUTY TEST LEAD SET
Stock : 1

1547885 electronic component of Fluke 1547885

Fluke METER CASE,LEATHER,LARGE
Stock : 1

1576734 electronic component of Fluke 1576734

Fluke FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS
Stock : 1

1610115 electronic component of Fluke 1610115

AC280 Suregrip Hook Clips
Stock : 0

1LAC-A electronic component of Fluke 1LAC-A

LOW VOLTAGE DETECTOR AMERICAS PACIFIC AVAILABLE IN 12 PA
Stock : 0

114519 electronic component of Fluke 114519

AC/DC CURRENT PROBE, SCOPEMETER(R)
Stock : 1

1503 electronic component of Fluke 1503

Insulation Resistance Testers
Stock : 0

1630 electronic component of Fluke 1630

Fluke 1630 Earth Ground Clamp Meter
Stock : 1

190-102/AM electronic component of Fluke 190-102/AM

Oscilloscope (DSO) + DMM - 2 Ch, 100 MHz -- 6" Color TFT LCD -- 8 bit, 1.25Gs/S Portable Scopemeter® ...
Stock : 1

1623-2-KIT electronic component of Fluke 1623-2-KIT

Basic GEO Earth Ground Tester Kit
Stock : 1

Image Description
MA120 electronic component of Teledyne FLIR / Extech MA120

Clamp Multimeters & Accessories Clamp Meter, Mini, AC/DC W/NCV/Flashlight
Stock : 2

499904 electronic component of Wurth 499904

Multi-Function Test Tweezer Tests Fuses, LEDs, PCB Circuit Conductivity, Resistance and Switches
Stock : 20

MINI 09 electronic component of Chauvin Arnoux MINI 09

AC current clamp adapter; Features: double insulated; 180g
Stock : 1

MA443 electronic component of Teledyne FLIR / Extech MA443

Clamp Multimeters & Accessories 400A TRUE RMS AC CLAMP METER + NCV
Stock : 0

UT220 electronic component of Uni-T UT220

AC digital clamp meter; Øcable:60mm; LCD (2000), with a backlit
Stock : 1

KEW105816 electronic component of Kyoritsu KEW105816

AC/DC current clamp adapter; KT2001A
Stock : 1

KEW7146 electronic component of Kyoritsu KEW7146

Adapter for clamps; banana 4mm plug x2
Stock : 4

KEW2031 electronic component of Kyoritsu KEW2031

AC digital clamp meter; Øcable: 24mm; LCD; I AC: 20A,200A; 100g
Stock : 1

P 1615 electronic component of PEAKTECH P 1615

AC/DC digital clamp meter; Øcable: 35mm; I DC: 40A,400A,1kA; 300g
Stock : 1

P 1635 electronic component of PEAKTECH P 1635

AC/DC digital clamp meter; Øcable: 18mm; I DC: 2A,80A; 180g
Stock : 6

i40s-EL Current Clamp Safety Information Go to www.fluke.com to register your product, download manuals, and find more information. A Warning identifies conditions and procedures that are dangerous to the user. Warning To prevent possible electrical shock, fire, or personal injury: Read all safety information before you use the Product. Use the Product only as specified, or the protection supplied by the Product can be compromised. Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed. Do not use the Product around explosive gas, vapor, or in damp or wet environments. Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. Use the Product only on insulated conductors. Use caution around bare conductors or bus bars. To prevent electrical shock, do not touch the conductor. Do not use the Product if it is damaged. Do not use the Product if it operates incorrectly. PN 4393640 September 2013 2013 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Before each use, examine the Product. Look for cracks or missing pieces of the clamp housing or output cable insulation. Also look for loose or weakened components. Carefully examine the insulation around the jaws. Do not use a current measurement as an indication that a circuit is safe to touch. A voltage measurement is necessary to know if a circuit is hazardous. Have an approved technician repair the Product. Remove the Product from conductor before you clean the Product. Do not hold the Current Clamp anywhere beyond the tactile barrier. Specifications Safety ..................................... IEC 61010-1: Overvoltage CAT IV, Measurement 600 V CAT III / 300 V CAT IV, Pollution Degree 2 Temperature Operating ...................... -10 C to +55 C (-14 F to 131 F) Storage ......................... -20 C to +70 C (-4 F to 158 F) Altitude Operating ...................... 2,000 m (up to 4,000 m derate to 600 V CAT II/300 V CAT III) Storage ......................... 12,000 m

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free
FLUKE CALIBRATION
Fluke Electronics
FLUKE NETWORKS

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted