Product Information

I800

I800 electronic component of Fluke

Datasheet
Clamp Multimeters & Accessories AC CURRENT CLAMP

Manufacturer: Fluke
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 529.1868 ea
Line Total: USD 529.19

3 - Global Stock
Ships to you between
Tue. 21 May to Mon. 27 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - WHS 1


Ships to you between Tue. 21 May to Mon. 27 May

MOQ : 1
Multiples : 1

Stock Image

I800
Fluke

1 : USD 551.2369
3 : USD 523.6744
5 : USD 496.1119

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Accuracy
Ranging
Frequency
Voltage
Brand
Maximum Ac Current
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1273185 electronic component of Fluke 1273185

HEAVY DUTY TEST LEAD SET
Stock : 1

1547885 electronic component of Fluke 1547885

Fluke METER CASE,LEATHER,LARGE
Stock : 1

1576734 electronic component of Fluke 1576734

Fluke FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS
Stock : 1

1610115 electronic component of Fluke 1610115

AC280 Suregrip Hook Clips
Stock : 0

1LAC-A electronic component of Fluke 1LAC-A

LOW VOLTAGE DETECTOR AMERICAS PACIFIC AVAILABLE IN 12 PA
Stock : 0

114519 electronic component of Fluke 114519

AC/DC CURRENT PROBE, SCOPEMETER(R)
Stock : 1

1503 electronic component of Fluke 1503

Insulation Resistance Testers
Stock : 0

1630 electronic component of Fluke 1630

Fluke 1630 Earth Ground Clamp Meter
Stock : 1

190-102/AM electronic component of Fluke 190-102/AM

Oscilloscope (DSO) + DMM - 2 Ch, 100 MHz -- 6" Color TFT LCD -- 8 bit, 1.25Gs/S Portable Scopemeter® ...
Stock : 1

1623-2-KIT electronic component of Fluke 1623-2-KIT

Basic GEO Earth Ground Tester Kit
Stock : 1

Image Description
MA120 electronic component of Teledyne FLIR / Extech MA120

Clamp Multimeters & Accessories Clamp Meter, Mini, AC/DC W/NCV/Flashlight
Stock : 2

499904 electronic component of Wurth 499904

Multi-Function Test Tweezer Tests Fuses, LEDs, PCB Circuit Conductivity, Resistance and Switches
Stock : 20

MINI 09 electronic component of Chauvin Arnoux MINI 09

AC current clamp adapter; Features: double insulated; 180g
Stock : 1

MA443 electronic component of Teledyne FLIR / Extech MA443

Clamp Multimeters & Accessories 400A TRUE RMS AC CLAMP METER + NCV
Stock : 0

UT220 electronic component of Uni-T UT220

AC digital clamp meter; Øcable:60mm; LCD (2000), with a backlit
Stock : 1

KEW105816 electronic component of Kyoritsu KEW105816

AC/DC current clamp adapter; KT2001A
Stock : 1

KEW7146 electronic component of Kyoritsu KEW7146

Adapter for clamps; banana 4mm plug x2
Stock : 4

KEW2031 electronic component of Kyoritsu KEW2031

AC digital clamp meter; Øcable: 24mm; LCD; I AC: 20A,200A; 100g
Stock : 1

P 1615 electronic component of PEAKTECH P 1615

AC/DC digital clamp meter; Øcable: 35mm; I DC: 40A,400A,1kA; 300g
Stock : 1

P 1635 electronic component of PEAKTECH P 1635

AC/DC digital clamp meter; Øcable: 18mm; I DC: 2A,80A; 180g
Stock : 6

i800 AC/DC Current Clamp Instruction Sheet Introduction The i800 AC/DC Current Clamp (the Clamp) has been designed for use with multimeters, recorders, power analyzers, safety testers, etc. for accurate non-intrusive ac current measurement. Using the latest transformer technology, the Clamp range can measure currents from 100 mA to 800 A and is available with current or voltage outputs. The Clamp complies with the safety standards EN61010-2-032 for input and output circuits. Symbols The table below lists the symbols used on the Clamp and/or in this manual. Symbol Description Do not dispose of this product as unsorted municipal ~ waste. Go to Flukes website for recycling information. W Important Information. See manual. Hazardous Voltage. Risk of electric shock. X Double insulation. T Application around and removal from HAZARDOUS , LIVE conductors is permissible. ) Conforms to Canadian Standards Association. Complies with the relevant European standards. P Conforms to Australian standards. Equipment designed to protect against transients in equipment in fixed-equipment installations, such as CAT III distribution panels, feeders and short branch circuits, and lighting systems in large buildings. PN 2842289 June 2007 2007 Fluke Corporation. All rights reserved. Printed in France. i800 English Instruction Sheet Page 2 Safety Instructions Please read this section carefully. It will make you familiar with the most important safety instructions for handling the Clamp. In this instruction sheet, a Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and actions that may damage the Clamp or the test instruments. WX Warning The Clamp may only be used and handled by qualified personnel. To avoid electric shock or personal injury, follow these precautions: Do not use the Clamp if damaged. Always connect to display device before it is installed around the conductor. If the Clamp is not used as specified by the manual, protection provided by the Clamp may be impaired. Do not clamp around a conductor before connecting current to the measuring equipment. Do not disconnect the output from the measuring equipment while the Clamp is still around a conductor. Connect the Clamp output to measuring equipment having safety receptacles. Do not use prior to consulting local and national safety codes and use of protective equipment is recommended. Do not hold the Clamp beyond the tactile barrier. Before each use, inspect the Clamp. Look for cracks or missing portions of the housing or output cable insulation. Also look for loose or weakened components. Pay particular attention to the insulation surrounding the jaws. Open and close the Clamp, noting detent action indicating proper mechanical operation of TM SIAC anti short circuit feature. Use caution when working with voltages above 60 V dc, 30 V ac rms or 42 V ac peak. Such voltages pose a shock hazard. Do not use Clamp in wet environments or in locations that hazardous gases exist.

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free
FLUKE CALIBRATION
Fluke Electronics
FLUKE NETWORKS

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted