SERIES 28 HiPer-D Combo Connectors 280-046P combo cable pin connectors with standard mounting flange, crimp termination Combo HiPer-D pin connectors feature size 20 signal contacts and size 8 power or coax contacts. Size 8 contacts are ordered separately. The HiPer-D features a rugged machined aluminum shell, waterproof sealing and optional ground springs for improved resistance to electromagnetic interference. Size 20 contacts are packaged with connector. Terminate contacts with crimp tools purchased separately. Glass-reinforced thermoset epoxy insulators, copper alloy retention clips. Fluorosilicone face seal and rear grommet meet IP67 immersion requirement. 1000 VAC, 7.5 Amps ( 20), up to 40 Amps with size 8 power contacts. How To Order Sample Part Number 280-046P 3-5W5 MT G P Basic Part Number 280-046P Shell Size - See Shell Size - Contact Arrangements Table Contact Arrangement C ME = Electroless Nickel Z2 = Gold Shell Finish MT = Nickel-PTFE Z1 = Passivated Stainless Steel JF = Cadmium with Yellow Chromate G = Supplied with EMI Ground Spring Ground Spring N = No Ground Spring N = No Hardware (Through-Hole) K = Jackscrew, Slot Head, Extended Length Mating Hardware P = 4-40 Female Jackpost S = Screwlock, Male, Hex Head, Low Profile L = Jackscrew, Hex Head, Low Profile T = Screwlock, Male, Slot Head, Extended Length Contact Arrangements Specifications Mating Hardware Contact Size and Qty Shell Size- N P 20 7.5 AMPS, 8 40 Current Rating Contact Arr. Thru-Hole Female Jackpost AMPS 20 8 No Hardware 1-2W2 2 Test Voltage 1000 VAC RMS 1-5W1 4 1 4-40 UNC-2A Insulation 5000 megohms 2-3W3 3 Resistance minimum NUT AND LOCKWASHER 2-7W2 5 2 Operating -65 C. to +200 C. 2-11W1 10 1 .115/.125 Temperature 4-40 UNC-2B (2.92/3.18) 3-5W5 5 Ingress Protection IP 67 S L 3-9W4 5 4 Shock 300 g. Captive Screwlock, Captive Jackscrew, 3-13W3 10 3 Hex Head Hex Head Vibration, Random 43.92 g. 3-17W2 15 2 3-21W1 20 1 RETAINER 4-8W8 8 Materials and Finishes RETAINER 4-13W6 7 6 Shell Aluminum alloy 4-40 UNC-2A 4-40 UNC-2A 4-17W5 12 5 Copper alloy, 50 Contacts 4-21WA4 17 4 K T microinches gold Slot-Head Extended Slot-Head Extended 4-25W3 22 3 Insulators Thermoset epoxy Jackscrew Captive Screwlock 4-27W2 25 2 Copper alloy, nickel EMI Spring 5-24W7 17 7 plated 1.1 (28) 1.1 (28) 5-36W4 32 4 MAX MAX Retention Clips Copper alloy 5-43W2 41 2 RETAINER RETAINER Grommet, Face 5-47W1 46 1 Fluorosilicone rubber 4-40 UNC-2A 4-40 UNC-2A Seal Hardware 300 series stainless steel C-6 2015 Glenair, Inc 1211 Air Way, Glendale, CA 91201 818-247-6000 www.glenair.com U.S. CAGE code 06324 Series 28 HiPer-D catalog Rev. 09.04.20 Dimensions in Inches (millimeters) are subject to change without notice.SERIES 28 HiPer-D Combo Connectors 280-046P combo cable pin connectors with standard mounting flange, crimp termination 280-046P DIMENSIONS OPTIONAL SEALING BOOT SUPPLIED WITH CONTACT OR ORDERED SEPARATELY 1.129 (28.68) (REF) A .120 (3.05) C TYP .435 D (11.05) C .049 F REF .134R (1.24) (3.40) A5 A4 A3 A2 A1 A1 A2 A3 A4 A5 E B G BACKSHELL OPTIONAL GROUND .262 .005 10 MOUNTING SPRING 2 PLCS (6.65 0.13) 10 TYP GROOVE TYP Dimensions A B C Basic D E F Max. G Max. Shell in mm in mm in mm in mm Size .015 0.38 .015 0.38 in. mm .005 0.13 .005 0.13 in. mm in. mm 1 1.213 30.81 .494 12.55 .984 24.99 .726 18.44 .389 9.88 .769 19.53 .432 10.97 2 1.541 39.14 .494 12.55 1.312 33.32 1.054 26.77 .389 9.88 1.093 27.76 .432 10.97 3 2.088 53.04 .494 12.55 1.852 47.04 1.594 40.49 .389 9.88 1.635 41.53 .432 10.97 4 2.729 69.32 .494 12.55 2.500 63.50 2.242 56.95 .389 9.88 2.282 57.96 .432 10.97 5 2.635 66.93 .605 15.37 2.406 61.11 2.139 54.33 .501 12.73 2.188 55.58 .544 13.82 NOTES 1. See About Series 28 HiPer-D Shell Plating Options for additional shell material and finish options. Glenair offers the industrys widest selection of plating options with no minimum order quantities or setup charges. 2. For panel cutouts, refer to Panel Cutouts and Printed Circuit Board Footprints. 3. Connectors are supplied with size 20 crimp contacts per M39029. Contacts are not installed. Refer to HiPer-D Contacts and Tools section for contact part numbers, specifications, crimp tool information, and insertion/extraction tools. 4. Size 8 contacts are ordered separately. Refer to HiPer-D Contacts and Tools section for contact ordering information, specifications, crimp tool information, and insertion/extraction tools. 5. Combo HiPer-D connectors meet the applicable requirements of MIL-DTL-24308 and are intermateable with standard non- environmental D Subminiature connectors with corresponding contact arrangements and type. Size 8 contacts from other manufacturers cannot be installed in HiPer-D connectors. 6. Additional electrical, mechanical and environmental specifications are listed in HiPer-D Product Specification . 2015 Glenair, Inc 1211 Air Way, Glendale, CA 91201 818-247-6000 www.glenair.com U.S. CAGE code 06324 Series 28 HiPer-D catalog C-7 Dimensions in Inches (millimeters) are subject to change without notice.