GU MAIN FEATURE 1. Single contact Form (SPST) series Relay offers switching capacity 30A in small size. 2. Dust cover, sealed & unclosed cover types are available. 3. UL Class F insulation available. 4. Halogen Free series available. 5. Comply with RoHS and REACH regulations. CONTACT RATING Load Type GU (DM) GU (DB) GU (D) GU (D1) 30A 120VAC 10A 240VAC NC: 20A 240VAC NC: 10A 240VAC 30A 240VAC 10A 30VDC 10A 30VDC 10A 30VDC Rated Load (Resistive) 30A 30VDC - NO: 30A 240VAC NO: 20A 240VAC - - 20A 30VDC 20A 30VDC TV-8 120VAC - TV-8 120VAC TV-8 120VAC NO 1-1/2HP 240VAC - 1-1/2HP 240VAC 1-1/2HP 240VAC Contact Capacity NC - 1/2HP 240VAC 1/2HP 240VAC 1/2HP 240VAC Rated Carrying Current 30A 10A 30A 20A Max. Allowable Voltage AC 240V AC 240V AC 240V AC 240V Max. Allowable Current 30A 10A 30A 20A Max. Allowable Power 7,200VA 2,400VA 7,200VA 4,800VA Force 900W 300W 600W 600W Contact Material Ag Alloy Ag Alloy Ag Alloy Ag Alloy Contact Form SPST SPST SPDT SPDT APPLICATION Temperature Range ........ -25 +55 C Domestic Appliances, Heating, Ventilating and Humidity Range ............... 45 85% RH. Conditioning System, Car Control Switching Box, Coil Temperature Rise .... 60 C Max. General Power Switching Applications. Vibration: Destruction ...................... 10 to 55 to 10 Hz,0.75 mm single amplitude (1.5mm double amplitude) PERFORMANCE (AT INITIAL VALUE) Malfunction ...................... 10 to 55 to 10 Hz,0.75 mm single Contact Resistance ..............100m Max. 1A,6VDC amplitude (1.5mm double amplitude) Operate Time........................15 mSec. Max. Shock: Release Time .......................10 mSec. Max. 2 Destruction ...................... 1,000 m/S Dielectric Strength: 2 ...................... 50 m/S Malfunction Between Coil & Contact.......1,500VAC at 50/60 Hz Life Expectancy: for one minute 7 Mechanical ...................... 10 Operations at No Between Contacts ................1,500VAC at 50/60 Hz Load condition for one minute 5 Electrical .......................... 10 Operations at Insulation Resistance...........100 Mega Min. at Resistive Load 500VDC Weight ............................. Flow Solder Type: 27.2g Max. On/Off Switching: Open Type: 21.6g Electrical ...............................6 Cycles per Minute Mechanical............................300 Cycles per Minute SAFETY STANDARD & FILE NUMBER UL & C-UL ....................... E141060 98GU GU COIL SPECIFICATION (AT 20C) Power Maximum Pull-In Voltage Drop-Out Nominal Nominal Coil Resistance Coil Sensitivity Consumption Allowable (VDC) Voltage (VDC) Voltage (VDC) Current (mA) (10%) (W) Voltage (VDC) 5 185 27 6 150 40 9 93 97 12 77 155 150% 80% 5% GU-D 15 59 255 (for short time Abt. 0.93 Maximum Minimum 18 47 380 carrying current) 24 36 660 36 25.8 1,390 48 19.4 2,480 110 8.5 13,000 ORDERING INFORMATION GU - SS - 1 12 D M CF 1 - 5 Terminal Type: Nil: 2 Common 5: 1 Common Load rated(For GU-D Series only): Nil: NO:30A/NC:20A. 1: NO:20A/NC:10A. Insulation System: Nil: Standard Class CF: Class F Contact Form: Nil: One Form C M: One Form A B: One Form B Coil Type: D: Standard DC Coil Voltage: 05: 5V, 06: 6V, 09: 9V, 12: 12V, 15: 15V, 18: 18V, 24: 24V, 36: 36V, 48: 48V, 110: 110V Number of Pole: 1: One Pole Type of Sealing: Nil: RT 0 Unclosed SS: RT II Flux Proofed SH: RT III Wash Tight Type: GU CLASSIFICATION Model GU Insulation System Nil: Standard Class / CF: Class F Contact Form 1C 1A 1B Unclosed Relay GU-1 D(CF)(1) GU-1 DM(CF) GU-1 DB(CF) Flux Proofed Type GU-SS/SH-1 D(CF)(1) GU-SS/SH-1 DM(CF) GU-SS/SH-1 DB(CF) V.01EZ www.goodsky.com.tw 99