Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
HS1E
Solenoid Locking Safety Switches
HS1E Full Size Solenoid Locking Switches
Key features:
Plastic Housing: Lightweight
1500N locking retention force
Available with a red or green indicator
Choose from 4 circuit configurations
Flexible Installation: The actuator can be accessed from two directions
Ease of Wiring: M3.5 termination screws
Part Numbers (Mechanical Spring Lock Only) Actuator Keys & Accessories
Contact Configuration LED Standard Manual Unlock Key Appearance Part Number Description
1
Straight
Monitor Circuit
None HS1E-40R HS1E-40KR
HS9Z-A1
2
Actuator
3
Main Circuit
Main circuit: 1NC + 1NC 4
Right-angle
Green HS1E-44R-G HS1E-44KR-G
HS9Z-A2
Monitor circuit: 1NO/1NO
5
Actuator
Solenoid Power
6
Indicator
Adjustable
7
Contacts are linked to Red HS1E-44R-R HS1E-44KR-R
HS9Z-A3
Actuator
the solenoid mechanically.
8
Key Wrench
1
HS9Z-T1 (included with
Monitor Circuit None HS1E-140R HS1E-140KR
2
switch)
3
Conduit
Main Circuit
Main circuit: 1NC + 1NC 4
HS9Z-P1 Opening Plug
Green HS1E-144R-G HS1E-144KR-G
Monitor circuit: 1NO
5 (G1/2)
Solenoid Power
6 Indicator
7
Red HS1E-144R-R HS1E-144KR-R
Contacts are linked to
8
the solenoid mechanically.
1
None HS1E-240R HS1E-240KR
Monitor Circuit
2
3
Main Circuit
Main circuit: 1NC + 1NC 4
Green HS1E-244R-G HS1E-244KR-G
+
Monitor circuit: 1NC + 1NC
5
Solenoid Power
6
Indicator
7
Contacts are linked to
Red HS1E-244R-R HS1E-244KR-R
the solenoid mechanically.
8
1
Monitor Circuit None HS1E-340R HS1E-340KR
2
3
Main Circuit
4
Main circuit: 1NC + 1NC
Green HS1E-344R-G HS1E-344KR-G
+
Monitor circuit: 1NC
5
Solenoid Power
6
Indicator
7
Contacts are linked to Red HS1E-344R-R HS1E-344KR-R
the solenoid mechanically.
8
1. Key wrench for TORX screws (HS9Z-T1) is supplied with the interlock switch.
2. Actuator is not supplied with the interlock switch, and must be ordered separately.
3. Manual unlock key is included with the interlock switch.
4. TORX is a registered trademark of Camcar Textron.
1705151128
800-262-IDEC (4332) USA & Canada
341HS1E
Solenoid Locking Safety Switches
Specifications
EN1088, IEC60947-5-1, EN60947-5-1(TUV), ISO14119, GS-ET-19 (BG), UL508, CSA C22.2 No. 14,
Conforming to Standards
GB14048.5 (CCC approval), IEC60204-1, EN60204-1 (applicable standards for use)
Operating Temperature 20 to +40C (no freezing)
Storage Temperature 40 to +80C
Relative Humidity 40 - 85% RH (no condensation)
Altitude 2,000m maximum
Rated Insulation Voltage (Ui) 300V (between LED or solenoid and ground: 60V)
Impulse Withstand Voltage (Uimp) 4 kV (between LED or solenoid and ground: 2.5 kV)
Between live and dead metal parts: 100 M minimum
Insulation Resistance Between live metal part and ground: 100 M minimum
(measured with 500V DC megger) Between live metal parts: 100 M minimum
Between terminals of the same pole: 100 M minimum
Electric Shock Protection Class II (according to IEC61140)
Pollution Degree 3 (IEC60947-5-1)
Degree of Protection IP67 (IEC60529)
Operating Extremes 10 to 55 Hz, minimum (amplitude 0.35 mm)
Vibration
2
Resistance
Damage Limits 50 m/sec (approx. 5G)
2
Shock Resistance 1,000 m/sec (approx. 100G)
Actuator Retention Force 1,500N minimum (per GS-ET-19)
Actuator Operating Speed 0.05 to 1.0m/s
Direct Opening Travel 11mm minimum
Direct Opening Force 20N minimum
Thermal Current (I ) Main circuit: 10A, Auxiliary circuit: 3A
th
Contact Gap Main circuit: 1.7 mm min., Auxiliary circuit: 1.2 mm min.
Operating Frequency 900 operations/hour max.
1,000,000 operations min. (at full rated load)
Mechanical Life
900 ops/hr (AC-12/250V, 6A)
Electrical Life 100,000 operations (rated load)
Conditional Short-circuit Current 100A (per IEC60947-5-1)
Recommended Short Circuit Protection 250V, 10A fuse (Type D01 based on IEC60269-1, 60269-2)
Operating Voltage 24V DC
Current 292mA (initial value)
Coil Resistance 102 (at 20C)
Solenoid
Pickup Voltage 20.4V maximum (at 20C)
Unit
Drop Out Voltage 2.4V minimum (at 20C)
Allowable Voltage 26.4V max (continuous)
Insulation Class Class F
Operating Voltage 24V DC
Current 10mA
Indicator
Light Source LED lamp
Lens Color Red or Green
Weight (approx.) 500g
Contact Ratings
Operating Voltage (Ue) 30V 125V 250V
Resistive load (AC12) 10A 10A 6A
AC
Inductive load (AC15) 10A 5A 3A
Resistive load (DC12) 6A
DC
Rated Operating Current (Ie) Inductive load (DC13) 3A 0.9A
Resistive load (AC12) 3A 3A
AC
Inductive load (AC15) 3A
Resistive load (DC12) 3A
DC
Inductive load (DC13) 0.9A
1705151128
www.IDEC.com
342
AS-Interface Safety at Work Light Curtains Safety Control Relays Enabling Switches Interlock Switches XW Series E-Stops Overview
Auxiliary Main
Circuit Circuit