EU-CF 2014-03 Inhalt EU-CF-INHALT 2014-03 03.03.14 20:10 Seite 124 CF240 CF240 PVC PVC 10-12 x d PVC Data cable CF240 Class 4.3.2 (4 medium load requirements 3 travel distance up to 50 m 2 oil-resistant) 10-12 x d for medium load requirements Silicon-free Free from silicon which can affect paint adhesion PVC outer jacket (following PV 3.10.7 status 1992). shielded UL/CSA Style 10493 and 2464, 300 V, 80 C oil-resistant flame-retardant NFPA Following NFPA 79-2012 chapter 12.9 CEI Following CEI 20-35 CE Following 2006/95/EG Conductor Very finely stranded special cores of particularly high-flex design made of bare copper wires. Lead free Following 2011/65/EC (RoHS-II) Core insulation Mechanically high-quality PP mixture. Clean room According to ISO Class 1. Outer jacket material complies with CF240.02.24, tested Core stranding The individual cores are stranded in layers with short pitch by IPA according to standard 14644-1 o lengths. CTP Certified according to N C-DE.PB49.V.00396 Core identification Colour code in accordance with DIN 47100. o EAC Certified according to N TC RU C-DE.ME77.B.00960 Intermediate layer Foil taping over the external layer. Overall shield Extremely bending-resistant braiding made of tinned copper New Guaranteed lifetime for this series according to thechainflex guarantee clu conditions Page 22-25 wires. Coverage approx. 70% linear, approx. 90% optical. Double strokes* 5 million 7,5 million 10 million Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adap- Temperature, Travel distance R min. factor x d R min. factor x d R min. factor x d ted to suit the requirements in energy chains (following DIN VDE from/to C m < 10 m 10 m < 10 m 10 m < 10 m 10 m 0281 Part 13). +5 / +15 12,5 15 13,5 16 14,5 17 Colour: Silver grey (similar to RAL 7001) +15 / +60 50 10 12,5 11 13,5 12 14,5 Bending radius moved < 10 m travel moved minimum 10 x d +60 / +70 12,5 15 13,5 16 14,5 17 10 m travel moved minimum 12 x d * higher number of double strokes possible fixed minimum 5 x d Temperature moved +5 C to +70 C for use in energy chains Typical application area with > 50.000 cycles for medium load requirements -5 C to +70 C following DIN EN 60811, light oil influence part 1-4 chapter 8.2 preferably indoor applications, but also outdoor ones at temperatures > 5 C fixed -20 C to +70 C freely suspended travel distances and up to 50 m for gliding applications v max. 3 m/s, 2 m/s Storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor unsupported/gliding cranes 2 a max. 20 m/s Travel distance Freely suspended travel distances and up to 50 m for gliding applications, Class 3 Nominal voltage 300/300 V (following DIN VDE 0245). Testing voltage 1500 V Oil Oil-resistant (following DIN EN 50363-4-1), Class 2. Flame-retardant According to IEC 60332-1-2, CEI 20-35, FT1, VW-1 125 Image exemplary.EU-CF 2014-03 Inhalt EU-CF-INHALT 2014-03 03.03.14 20:10 Seite 126 CF240 CF240 PVC PVC 10-12 x d PVC Data cable CF240 Class 4.3.2 (4 medium load requirements 3 travel distance up to 50 m 2 oil-resistant) 10-12 x d Image exemplary. Delivery program Number of cores and External Copper Weight Part No. conductor nominal diameter index kg/km 2 cross section mm max. mm kg/km CF240.01.03 (3 x 0,14)C 5,0 15 28 CF240.01.04 (4 x 0,14)C 5,0 16 32 CF240.01.05 (5 x 0,14)C 5,5 18 35 CF240.01.07 (7 x 0,14)C 6,0 25 45 CF240.01.14 (14 x 0,14)C 7,5 43 74 CF240.01.18 (18 x 0,14)C 8,0 54 93 CF240.01.24 (24 x 0,14)C 9,0 67 128 CF240.02.03 (3 x 0,25)C 5,0 18 35 CF240.02.04 (4 x 0,25)C 5,5 21 46 CF240.02.05 (5 x 0,25)C 5,5 26 43 CF240.02.07 (7 x 0,25)C 6,5 33 55 CF240.02.08 (8 x 0,25)C 7,0 37 63 CF240.02.14 (14 x 0,25)C 8,0 63 93 CF240.02.18 (18 x 0,25)C 8,5 75 111 CF240.02.24 (24 x 0,25)C 9,5 100 166 CF240.03.02 (2 x 0,34)C 5,5 20 38 CF240.03.03 (3 x 0,34)C 5,5 27 40 CF240.03.04 (4 x 0,34)C 6,0 31 52 CF240.03.05 (5 x 0,34)C 6,0 36 57 CF240.03.07 (7 x 0,34)C 7,5 48 77 CF240.03.10 (10 x 0,34)C 8,5 63 98 CF240.03.14 (14 x 0,34)C 9,0 79 116 CF240.03.18 (18 x 0,34)C 10,0 96 142 CF240.03.24 (24 x 0,34)C 11,0 127 184 Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core 126 127