Current Sensors FG, Fluxgate-Based Residual Current Sensor Overview Applications The FG-R01-4A sensor is a high-sensitivity AC and DC Typical applications include residual current sensor for leakage current sensor with individual open drain alarms In-Cable Control and Protection Devices (IC-CPD) or Wallbox. and an analog output for leakage current indication. In addition, its integrated test coil can be initiated by a test input to perform a functional alarm test. Benefits O p e n - l o o p , fl u xga te - bas e d c u r r e n t s e ns o r PCB mounting Digital output of fault detection Conforms to IEC 62752:2016/A1:2018 1 Conforms to IEC 62955:2018 Conforms to UL 2231-2 RoHS compliant 3,000 A surge current capability Ordering Information FG- R01- 4A Series Shape Current Detection Standards FG R01 = Horizontal without busbar 4A = IEC 62752:2016/A1:2018 and 1 UL 2231-2, IEC 62955:2018 1 Conditional and dependant on the circuit/system designed as explained in the section Recommended Circuit of this datasheet. Built Into Tomorrow KEMET Electronics Corporation KEMET Tower One East Broward Boulevard SE0223 FG-R01-4A 6/10/2022 1 Fort Lauderdale, FL 33301 USA 954-766-2800 www.kemet.comCurrent Sensors FG, Fluxgate-Based Residual Current Sensor Dimensions in mm 34.45 13.5 11.6 3.5 21.57 (HOLE) 8 7 26.6 9 10 6 5 4 3 2 1 0.7 3.1 30.5 P2.545 = 12.70 Pin Number Symbol 1 VDD 2 GND 3 AOUT 4 DC Fault 5 AC Fault 6 TEST 7-10 Dummy KEMET Electronics Corporation KEMET Tower One East Broward Boulevard SE0223 FG-R01-4A 6/10/2022 2 Fort Lauderdale, FL 33301 USA 954-766-2800 www.kemet.com 6- 0.6 4- 0.8 49.85 10.9 13.3 15.4 28.58