Preset counters, electronic LED preset counters Multifunction pulse, frequency, time 60 kHz, 2 presets (AC+DC) Codix 560 With its automatic help texts, clearly and legibly displayed on 14 LED segments, the Codix 560 preset counter takes the user effort- lessly through the programming. The large user-friendly front keys can be operated even when wearing gloves. The 14 mm high LED display ensures easy reading even from a long distance and in poor lighting conditions. New: now available also with RS232/485 interface and MODBUS and CR/LF protocol RoHS 000000 DC AC t Hz 100 ... 240 V POSITION LEDs 10 ... 30V 65 kHz HRA - 20 + 65 DIN 96 x 48 IP65 t Hz Power supply Temperature DIN front bezel Menu-driven High protection High count Multifunction Frequency dis- Position 14 segment range programming level frequency play with HRA display LED 00000 Batch 232 RS 485 Batch Total counter Optional counter interface Multifunction User-friendly Counter, tachometer, timer and position display in Automatic help texts, displayed in German and English one device 14-segment LED for improved text representation Can be used as preset counter, batch counter or total counter Status display of the presets 2 relays (change-over) 3 predefined parameters Many different count modes Tracking presets eliminate the need for reprogramming of the Scalable display pre-signal Set value, step or tracking preset Minimum installation depth Multi-range power supply for AC or DC 4-stage RESET modes Readable or configurable via RS232/485 interface 3-stage keypad locking via MODBUS or CR/LF protocol Suitable for installation in mosaic systems Allows direct connection of a large display or printer Order Code 6.560 . 010 . X X X a b c a b c Delivery specification Power supply Input trigger levels Interface (optional) 1) 1) 0 = 100 ... 240 V AC, 10% 0 = Standard level (HTL) 0 = None - Preset counter 1) - Mounting clip 3 = 10 ... 30 V DC A = 4...30 V DC level 5 = RS232 (MODBUS or CR/LF) 7 = RS485 (MODBUS or CR/LF) - Instruction manual Accessories Dimensions in mm inch Order-No. For snap-on mounting on 35 1.38 top-hat DIN rail, Mounting frame for counters 96 x 48 3.78 x 1.89 grey G300005 with cut-out 92 x 45 3.62 x 1.77 Suitable gaskets as well as further accessories can be found in the accessories section or in the accessories area of our website at: www.kuebler.com/accessories. 1) Stock types 138138 www.kuebler.com Fritz Kbler GmbH, subject to errors and changes. 03/2014Preset counters, electronic LED preset counters Multifunction pulse, frequency, time 60 kHz, 2 presets (AC+DC) Codix 560 Technical data General technical data Inputs Display 6-digit red 14 segment LED display, Count inputs A and B 14 mm 0.55 high Polarity of the inputs programmable for all inputs Operating temperature -20C ... +65C -4F ... +149F in common, NPN/PNP (non-condensing) Input resistance 5 kW Storage temperature -25C ... +75C -13F ... +167F Count frequency Pulse counters max. 55 kHz Relative humidity at +40C +104F RH 93% (non-condensing) Tachometers max. 65 kHz can be damped to 30 Hz Altitude up to 2000 m 6562 (mechanical contacts) ( details s. instruction manual) Electrical characteristics Control / Reset input MPI 1 and MPI 2, Power supply AC 100 ... 240 V AC, 10% Lock, Gate, Reset max. 11 VA, 50/60 Hz Min pulse duration of the inputs 10 ms /1 ms DC 10 ... 30 V, max. 5.5 W Switching levels HTL-level: LOW: 0 ... 4 V DC External fuse protection 230 V AC T 0.1 A with AC supply HIGH: 12 ... 30 V DC 10 ... 30 V DC T 0.25 A 4 ... 30 V DC: LOW: 0 ... 2 V DC Data retention > 10 years, EEPROM HIGH: 3.5 ... 30 V DC Response time of the frequency meter 100 / 600 ms Switching levels HTL-level: LOW: 0 ... 0.2 x UB ( details s. instruction manual) with DC supply HIGH: 0.6 x UB ... 30 V DC 4 ... 30 V DC: LOW: 0 ... 2 V DC Input modes Pulse counters: Count direction (cnt.dir), HIGH: 3.5 ... 30 V DC Difference (up.dn), Addition A+B (up.up), Pulse shape variable, Schmitt-Trigger phase discriminator x1, x2, x4 characteristics (quad, quad x2, quad x4), Ratio (A/B), Outputs Ratio in % ((A-B)/A x100%) Switching voltage max. 250 V AC / 150 V DC Frequency meter: A, A-B, A+B quad, A/B, (A-B)/A x 100% Switching current max. 3 A AC / DC Timer: 4 start modes: FrErun, min. 30 mA DC Auto, InpA.InpB., InpB.InpB. Switching capacity max. 750 VA / 90 W Sensor power supply AC supply 24 V DC 15%, 80 mA Output 1 + 2 DC supply max. 80 mA, external power 7 Mech. service life (switching cycles) 2 x 10 supply is connected through 4 N of switching cycles at 3 A / 250 V AC 5 x 10 4 EMC Emitted interference EN 55011 class B N of switching cycles at 3 A / 30 V DC 5 x 10 Immunity to interference EN 61000-6-2 Relay with changeover contact Device safety Designed to EN 61010 part 1 Reaction time of the outputs 13 ms Protection class 2 (pulse / time) (details s. instruction manual) Application area Pollution level 2 UL approval File No.: E128604 Optional interface MODBUS and CR/LF Count frequency max. 45 kHz ( details s. instruction manual) Mechanical data Interface RS232, RS485 Protection IP65 (from the front) Baud rate 9600 Weight approx. 180 g 6.35 oz Device address 1 ... 99, programmable Terminal assignment Pin Signal and control inputs Pin Version with relay/optocoupler 1 INP A (Signal input A) 10 Relay contact C.2 Output 2 2 INP B (Signal input B) 11 Relay contact N.O.2 3 RESET (Reset input) 12 Relay contact N.C.2 4 LOCK (Keypad lock) 13 Relay contact C.1 Output 1 5 GATE (Gate input) 14 Relay contact N.O.1 6 MPI 1 (User input 1) 15 Relay contact N.C.1 Pin RS232 (optional) Pin RS485 (optional) 7 MPI 2 (User input 2) 16 AC: 100 ... 240 V AC, 10%, N~ 22 GND 22 DC: 10 ... 30 V DC Power 8 Sensor power supply 23 RXD 23 DO supply AC: 24 V DC/80 mA 17 AC: 100 ... 240 V AC, 10%, L~ 24 TXD 24 DI DC: U connected through DC: GND (0 V DC) B 25 25 9 Shared connection for signal and control inputs GND (0 VDC) 26 26 Fritz Kbler GmbH, subject to errors and changes. 03/2014 www.kuebler.com 139139 Z1500 6.560.010.XXX Preset counters