Product Information

TT 100-SD

TT 100-SD electronic component of Lem

Datasheet
CURRENT TRANSFORMER, 100A, PANEL

Manufacturer: Lem
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 52.7867 ea
Line Total: USD 52.79

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Warehouse 1


Ships to you between Mon. 06 May to Fri. 10 May

MOQ : 1
Multiples : 1
1 : USD 52.7867
10 : USD 43.1298
25 : USD 41.6911
50 : USD 39.5081

     
Manufacturer
Product Category
Turns Ratio
Input Current
Frequency Min
Frequency Max
Transformer Mounting
Product Range
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
CKSR 25-NP electronic component of Lem CKSR 25-NP

SENSOR CURRENT FLUX 25A AC/DC
Stock : 1

CAS 50-NP electronic component of Lem CAS 50-NP

SENSOR CURRENT FLUX 50A AC/DC
Stock : 2

AT150B420L electronic component of Lem AT150B420L

CURRENT TRANSDUCER, 150A, CURRENT O/P
Stock : 0

AT100B420L electronic component of Lem AT100B420L

CURRENT TRANSDUCER, 100A, CURRENT O/P
Stock : 0

DHR 600 C10 electronic component of Lem DHR 600 C10

Current Transducer,600A, 0-10V O/P
Stock : 0

DHR 1000 C420 electronic component of Lem DHR 1000 C420

Current Transducer,1000A, 4-20Ma O/P
Stock : 0

AT20B420L electronic component of Lem AT20B420L

CURRENT TRANSDUCER, 20A, CURRENT O/P
Stock : 0

AT50B10 electronic component of Lem AT50B10

CURRENT TRANSDUCER, 50A, VOLTAGE O/P
Stock : 0

HAS300-S electronic component of Lem HAS300-S

Current Sensors Through Hole RoHS
Stock : 0

LAH100-P electronic component of Lem LAH100-P

Current Sensors Through Hole RoHS
Stock : 12

Image Description
Hot 56T100C electronic component of Murata 56T100C

Current Transformers 20-37mH at 1V 50kHz 10A 100CT turns
Stock : 1

AC1100 electronic component of Talema AC1100

Current transformer; Series: AC; 100A; Trans:1000:1; 100O; 1000mVA
Stock : 1

TI-EE16-0096 electronic component of Feryster TI-EE16-0096

Transformer: impulse; for power supplies; 2W; Works with: LNK362P
Stock : 0

TSZZ7/015M electronic component of Indel TSZZ7/015M

Transformer: encapsulated; 7VA; 230VAC; 24V; 0.29A; Mounting: PCB
Stock : 20

PB0027NL electronic component of Pulse PB0027NL

Current Transformers SMD Current Sense 22400uH 2.9Ohms
Stock : 1

TEZ4/D230/7.5V electronic component of Breve Tufvassons TEZ4/D230/7.5V

Transformer: encapsulated; 4VA; 230VAC; 7.5V; 533.3mA; IP00; 150g
Stock : 43

44094 electronic component of Myrra 44094

Transformer: encapsulated; 1.5VA; 230VAC; 15V; 15V; 50mA; 50mA
Stock : 50

HCT204ATN electronic component of Hop Tech HCT204ATN

Current Transformers 19.5*18.5*18.3 RoHS
Stock : 77

Hot CST25-0200 electronic component of Triad CST25-0200

Current Transformers PCB Curr Sense Xfmr 1:200,50-500KHz
Stock : 1

TSZZ2.5/012M electronic component of Indel TSZZ2.5/012M

Transformer: encapsulated; 2.5VA; 230VAC; 18V; 18V; 0.06A; 0.06A
Stock : 0

AC Current transformer TT 100-SD I = 100 A PN Split core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) and the secondary circuit (measurement). Electrical data I Primary nominal current rms 100 At PN Features I Output current 33.33 mA OUT V Output clamping voltage 7.5 V Split core type SZ Overload capability - continuous 300 A P 16 mm sensing aperture for non- - 1 min 4000 A contact measurement Cable output (1m) Isolated plastic case recognized Performance data according to UL 94-V0. X Overall accuracy I , T = 25C < 1 % G PN A Linearity error 0.1 % L TCI Temperature coefficient of I 60 ppm/K Advantages OUT OUT Phase shift 1.5 1 High accuracy and low phase shift BW Frequency bandwidth ( 1dB) 50/60 Hz High isolation between primary and secondary circuits General data Compact case Cost-effective solution T Ambient operating temperature - 25 .. + 70 C A T Ambient storage temperature - 30 .. + 90 C Easy installation. S m Mass 100 g IPxx Protection degree IP40 Applications Power meters Isolation characteristics Current measurement for active 1) V Rated isolation voltage rms 300 V b power calculation with IEC 61010-1 standards and following conditions : Energy sub-meters - Reinforced isolation For energy efficiency monitoring, - Over voltage category CAT III consumption analysis and costs - Pollution degree PD2 allocation - Heterogeneous field 2) Power quality monitoring V Rms voltage for AC isolation test , 50Hz, 1min 3.5 kV d V Impulse withstand voltage 1.2/50s 6.5 kV Condition monitoring w dCp Creepage distance 6 mm (e.g. motor loads such as dCl Clearance distance 6 mm conveyers, pumps or HVAC) CTI Comparative tracking index (Group I) 600 Distributed measurement systems 1) Application domain Notes : If insulated cable is used for the primary circuit, the voltage category could be improved according to the primary cable insulation category Energy and Automation (please refer to the cable manufacturer s indications) 2) between primary (completely filling the hole) and secondary. Page 1/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 071115/5 www.lem.comCurrent transformer TT 100-SD Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage The electric measuring transducer may only be installed and put into operation by qualified personnel that have received an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety requirements and in accordance with all the related systems and components manufacturers operating instructions. Caution Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 2/4 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 071115/5 www.lem.com

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
Beijing Lem
Beijing Lem Electronics
BEIJING LEM ELECTRONICS LTD.
LEM USA Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted