90W Constant Current Mode LED Driver L PF -90D series I P 6 7 File Name:LPF-90D-SPEC 2020-12-1090W Constant Current Mode LED Driver L PF -90D series SPECIFICATION MODEL LPF-90D-15 LPF-90D-20 LPF-90D-24 LPF-90D-30 LPF-90D-36 LPF-90D-42 LPF-90D-48 LPF-90D-54 15V 20V 24V 30V 36V 42V 48V 54V DC VOLTAGE 5A 4.5A 3.75A 3A 2.5A 2.15A 1.88A 1.67A RATED CURRENT RATED POWER Note.5 75W 90W 90W 90W 90W 90.3W 90.24W 90.18W 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V OUTPUT CONSTANT CURRENT REGION Note.2 5.0% max. rated current CURRENT RIPPLE CURRENT TOLERANCE 5.0% SETUP, RISE TIME Note.6 1200ms, 200ms / 115VAC 500ms, 200ms / 230VAC 16ms/230VAC 16ms/115VAC HOLD UP TIME (Typ.) 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.5 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF0.97/115VAC, PF0.96/230VAC, PF0.95/277VAC full load POWER FACTOR (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VC,230VAC load75%/277VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION(THD) section) INPUT EFFICIENCY (Typ.) 89% 89.5% 90% 90.5% 90.5% 90.5% 90.5% 90.5% AC CURRENT 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC INRUSH CURRENT(Typ.) COLD START 70A(twidth=435s measured at 50% Ipeak) at 230VAC Per NEMA 410 MAX. No. of PSUs on 16A 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.75mA / 240VAC 95 ~ 108% OVER CURRENT Constant current limiting, recovers automatically after fault condition is removed PROTECTION 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V 47 ~ 53V 54 ~ 60V 59 ~ 65V OVER VOLTAGE Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. Tcase=-40 ~ +70 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+70 20 ~ 95% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750(typeHL), CSA C22.2 No.250.13-12, TUV EN61347-1, EN61347-2-13, EAC TP TC 004, SAFETY STANDARDS Note.8 GB19510.1,GB19510.14,IP67 approved Design refer to UL60950-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Note.8 Compliance to EN55015,EN61000-3-2 Class C ( load60%) EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11 EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020 EMC IMMUNITY MTBF 1036.4K hrs min. Telcordia SR-332 (Bellcore) 267.2Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 161*61*36mm (L*W*H) 0.7Kg 20pcs/15Kg/0.73CUFT PACKING NOTE