MHBS MKP box with muliple radial or lug terminals high energy density DC-Link suitable for AC applications (*) suitable for high Irms switching applications (*) (*) upon restrictions Main applications Non recurrent surge voltage (Upk) DC-Link, switching capacitor for industrial and motor speed controls, Up to case T = +85C max. SMPS, solar inverters, power converters and UPS, AC output filtering, 750, 910, 1040, 1170, 1300, 1430, 1655 Vdc suitable for AC (not for across the line) applications Up to case T = +70C max. 815, 1000, 1140, 1300, 1430, 1560, 1820 Vdc Main characteristic High voltage and high capacitance in small size with long life expectancy, Self inductance high current and high frequency operation capability 1nH/mm of fixing pitch Dielectric Maximum pulse rise time V/s Polypropylene Refer to article table Electrodes Maximum peak current (Ipeak) Vacuum deposited metal layers Refer to article table. Max. non repetitive Ipk = 1,5 x Ipeak Coating RMS current (Irms) Solvent resistant plastic case with resin sealing (UL 94 V-0). Flame retardant Refer to article table. No superimposed Irms must be applied at Tamb > execution +95C (at Tamb > +95C Irms must be = 0) Construction Dissipation factor (DF), max. -4 Extended metallized film (refer to General Technical Information) tg x10 , measured at 25 5C, 1 kHz Terminals Cn 4 F 6 Tinned copper wire (lead-free). 2, 4 or 6x terminals or tinned copper (brass) 4 F < Cn 12 F (P 37,5 mm) 8 lug terminals (lead-free) execution (please refer to article table) 12 F (P 37,5 mm) < Cn 20 F 11 Degree of protection 20 F < Cn 40 F 14 IP00 40 F < Cn 75 F 18 Installation Whatever position assuring correct heat dissipation. Arrangement of many Cn > 75 F 22 components with box walls in contact not admitted suggested minimum Insulation resistance (R ) distance between side by side elements 1/8 of the box thickness (B size). INS 3000s (10000s typical) but need not exceed 3 G, between terminals, at Box with lugs terminals must be free to correctly dissipate from all the 25C, after 1 minute of electrification at 100 Vdc body faces Test voltage between terminals (Ut) Reference standard 1,5xUr (DC) or 1,5xUrms (AC) applied for 10s, at 25 5C IEC 61071, IEC 60068, RoHS compliant Test voltage between terminals and case (Utc) Climatic category 3kV 5060Hz applied for 60s at 25 5C 40/85/56 (IEC 60068/1), GPD (DIN40040) Please refer also to paragraph C10 (humid ambient) of the General Damp heat test (steady state) Technical Information Test conditions: Operating temperature range (case) Temperature = +40 2C -40...+85C (+100C observing voltage and current de-rating) Relative humidity =93 2% Test duration = 56 days Max. permissible ambient temperature (operation at rated power, rated current and natural cooling) Performance: +70C (+85C observing voltage and current de-rating) at Tamb > +95C Capacitance change 3% superimposed Irms not admitted (Irms= 0 at Tamb> +95C) DF change 2 x initial limit (1kHz) Nominal Capacitance (Cn) F R 50% of initial limit value INS 0,68 F to 100 F. Refer to article table Typical capacitance change versus operating time (at Tcase=+70C) Capacitance tolerance (at 1kHz) 5% after 30000 hours at Urms or after 100000 hours at Ur 10% (code=K), 5% (code=J). Other tolerances upon request Life expectancy Capacitance temperature coefficient 60000 hours at Urms or 200000 hours at Ur with T(case) +70C: Refer to General Technical Information expected life max. limit reference. 30000 hours at Urms or 100000 hours at Ur with T(case) = + 85C: Long term stability (at 1kHz) reference for expected life calculations at different operating conditions Capacitance variation 1% after a period of 2 years at standard (and expected life at max. admissible voltage at +70C, case). environmental conditions 10000 hours at de-rated Urms (Urms x 0.8) or 30000 hours at de-rated Rated voltage (Ur) (Vdc) at T = +85C, case (continuous operation) Ur (Ur x 0.8) at T(case) = +100C NO superimposed Irms applied. 575, 700, 800, 900, 1000, 1100, 1275 Vdc Failure quota Temperature de-rated voltage and current 9 300/10 component hours For operating temperature (case)> +85C, Ur, Urms, Upkr and Upk must be Resistance to soldering heat test decreased 1.5% for every C exceeding +85C. For current de-rating please also refer to the T/Tamb data in function of the applied Irms listed in the Test conditions: article table Solder bath temperature= +260 5C Dipping time (with heat screen)= 10 1s Permissible AC voltage (Urms) (Vac) at T = +85C, case (continuous operation) Performance: 240, 285, 315, 350, 400, 420, 440 Vac Capacitance change 1% Max. admissible voltage at T = +70C, case (continuous operation) DF change 0.0010 at 1kHz Please refer to the article table R 50% of initial limit value INS Max. repetitive peak voltage (Upkr), total max 1 hour/day Up to case T = +85C max. 660, 805, 920, 1035, 1150, 1265, 1465 Vdc Up to case T = +70C max. 720, 885, 1010, 1150, 1265, 1380, 1610 Vdc 17.1 EEdd. 04 R. 04 Revev. 00. 00 09.201809.2018MHBS MKP box with muliple radial or lug terminals high energy density DC-Link suitable for AC applications (*) suitable for high Irms switching applications (*) (*) upon restrictions Dimensions in mm (drawings not in scale) Style SP-SPM8 / SR-SRM8 Style VP-VPM8 / VR-VRM8 Fixing pitch and distance between lugs (mm) Style FP-FPM8 / FR-FRM8 Lugs style L P1 P2 SP-SPM8 4242,5 2328(M6) 2526(M8) 11min. VP-VPM8 57,5 3742(M6) 3940(M8) 24min. FP-FPM8 SR-SRM8 4242,5 2025(M6) 2223(M8) 8min. VR-VRM8 57,5 3439(M6) 3637(M8) 21min. FR-FRM8 Fixing slot size (mm)** SP, VP, FP, SR, VR, FR A= 6min. SPM8, VPM8, FPM8, SRM8, VRM8, FRM8 A= 8min. ** Standard fi xing slots for M6 screws, slots for M8 screws available upon request Style SN-SNM8 (for L=57,5mm only) Style VN-VNM8 (for L=57,5mm only) Fixing pitch and distance between lugs (mm) Fixing slot size (mm)** SN, VN A= 6min. Lugs style L P1 P2 SNM8, VNM8 A= 8min. 4242,5 Not available SN-SNM8 VN-VNM8 ** Standard fi xing slots for M6 screws, 57,5 2328 (M6) 2526 (M8) 11min. slots for M8 screws available upo request Style AP Fixing pitch and distance between lugs (mm) Lugs style L P1 P2 4242,5 53,563 (M8) - AP 57,5 68,577 (M8) - 17.2 Ed. 04 Rev. 00 09.2018