PPB MKP with double side met. current carriers box with radial terminals snubber high pulse applications high current high frequency Main applications Test voltage between terminals (Ut) Snubber, SCR commutating circuits, electronic ballasts, protection circuits 1,6xUr (DC) or 1,5xUrac (AC) applied for 2s at 255C (1 minute for type test) in SMPSs, defl ectors circuits in TV sets, high voltage, high current and high Damp heat test (steady state) pulse operation up to very high operating frequencies List of admitted high humidity and temperature tests (please refer to Dielectric paragraph C10 of the GTI) Polypropylene Biased tests applicable from 03/2019 production codes only Electrodes Test ID Reference Permissible Vacuum deposited metal layers Damp heat test (steady state) not biased a YES Coating - IEC60068 Solvent resistant plastic case with resin sealing (UL 94 V-0). Flame retardant Damp heat test (steady state) biased b YES execution - AEC Q-200 cockpit Robustness under high humidity, Grade II YES Construction c - IEC 60384-17:2019 (P 27.5mm ONLY) Extended double side metallized carrier film, internal series connection High robustness under high humidity, YES and metallized film for Ur 630 VDC (refer to General Technical d Grade III - IEC 60384-17:2019 (P 27.5mm ONLY) Information) Damp heat test (steady state) biased e YES Terminals - 70/70/1000 Tinned copper wire (lead-free) Humidity load test, Test Cy, Severity II f NO - IEC 60068-2-67 Reference standard Humidity load test, Test Cy, Severity III - IEC IEC 60384/16, IEC 60384/17, IEC 60068, RoHS compliant g NO 60068-2-67 and 85/85/1000 Level 1 - AEC Q-200 Climatic category Rated Ur (DC ONLY) applied for biased tests 55/100/56 (IEC 60068/1), FMD (DIN40040) Performance: Operating temperature range (case) Capacitance change 1% (for test a) -55...+105C Capacitance change 10% (for test b, c, d and e) DF change 0.0010 at 10kHz for Cn 1F (for test a) Nominal Capacitance (Cn) F DF change 0.0010 at 1kHz for Cn > 1F (for test a) 0,001F to 15F, in compliance with IEC 60063, E6 series. Refer to article DF change 2 x initial limit at 1kHz (for test b, c, d and e) table R 50% of initial limit value INS Capacitance tolerance (at 1kHz) Box distorsion 1/16 of the nominal box thickness (B size) or 1mm 10% (code=K), 5% (code=J) and 20% (code=M). Other tolerances whichever is the highest upon request Endurance test (DC) Capacitance temperature coefficient Test conditions: Refer to General Technical Information Temperature= +852C Test duration= 2000h Long term stability (at 1kHz) Voltage applied=1,25xUr(DC) Capacitance variation 0.5% after a period of 2 years at standard Performance: environmental conditions Capacitance change 1% Rated voltage (Ur) (Vdc) at 85C DF change 0.0010 at 10kHz for Cn 1F 250, 400, 630, 1000, 1600, 2000 Vdc DF change 0.0010 at 1kHz for Cn > 1F R 50% of initial limit value Permissible AC voltage at 60Hz (Vac) INS 160, 200, 400, 600, 650, 700 Vac AC (50/60Hz) Endurance test (for Ur>400Vdc ratings only) Test conditions: Category voltage (Uc) Temperature= +852C Uc=Ur at +85C Uc=0,8xUr (0,7xPermissible AC voltage) at +100C Test duration= 2000h Temperature de-rated voltage Voltage applied=1,25xUr(AC) For T> +85C, Ur must be decreased 1,25% (permissible AC voltage must Performance: be decreased 2,25%) for every C exceeding +85C Capacitance change 5% DF change 0.0010 at 10kHz for Cn 1F Self inductance DF change 0.0010 at 1kHz for Cn > 1F 1nH/mm of capacitor pitch R 50% of initial limit value INS Maximum pulse rise time V/s Resistance to soldering heat test Refer to article table. The pulse characteristic Ko depends on the voltage Test conditions: waveform. In any case the value given in the article table must not be Solder bath temperature= +2605C exceeded Dipping time (with heat screen)= 101s Dissipation factor (DF), max. Performance: -4 tg x10 , measured at 25 5C Capacitance change 1% DF change 0.0010 at 10kHz for Cn 1F Freq. Cn 0.1 F 0.1 F < Cn 1 F Cn > 1 F DF change 0.0010 at 1kHz for Cn > 1F 1kHz 5 4 5 R 50% of initial limit value INS 10kHz 5 6 - Reliability (MIL HDB 217) 100kHz 16 - - Application conditions: Applied voltage= 0,5 x Ur(DC) Temperature= +402C Insulation resistance (R ) INS -9 Failure rate: (1FIT=1x10 failures/components x hours) Measured between terminals, at 25C, after 1 minute of electrification at 2FIT for Ur 400Vdc 1FIT for Ur > 400Vdc 100Vdc Failure criteria (DIN44122): Cn R Capacitance change > 10% INS DF change > 2 x initial value 0.33 F 100 G R < 0,005 x initial limit value INS > 0.33 F 30000 s Short or open circuit 10.1 Ed. 04 Rev. 01 10.2021PPB MKP with double side met. current carriers box with radial terminals snubber high pulse applications high current high frequency PPB article table (different values available upon request) (3) (1) Voltage at +85C Cn Dimensions (mm) du/dt K ICEL CODE 0 2 Ur (Vdc) Urms (Vac) F B H L P d V/s V /s - 250 160 0,047 5 11 18 15 0,8 560 280000 PPB1252470*E 250 160 0,068 6 12 18 15 0,8 560 280000 PPB1252680*E 250 160 0,1 7,5 13,5 18 15 0,8 560 280000 PPB1253100*E 250 160 0,15 8,5 14,5 18 15 0,8 560 280000 PPB1253150*E 250 160 0,22 10 16 18 15 0,8 560 280000 PPB1253220*E 250 160 0,22 6 15 26,5 22,5 0,8 320 160000 PPB1253220*G 250 160 0,33 8,5 17 26,5 22,5 0,8 320 160000 PPB1253330*G 250 160 0,47 10 18,5 26,5 22,5 0,8 320 160000 PPB1253470*G 250 160 0,68 11 20 26,5 22,5 0,8 320 160000 PPB1253680*G 250 160 0,68 11 20 32 27,5 0,8 240 120000 PPB1253680*H 250 160 1 13 22 26,5 22,5 0,8 320 160000 PPB1254100*G 250 160 1 11 20 32 27,5 0,8 240 120000 PPB1254100*H 250 160 1,5 15 24,5 32 27,5 0,8 240 120000 PPB1254150*H 250 160 2,2 14 28 32 27,5 0,8 240 120000 PPB1254220*H 250 160 2,2 17 28 42,5 37,5 1 170 85000 PPB1254220*J 250 160 3,3 22 30 42,5 37,5 1 170 85000 PPB1254330*J 250 160 4,7 22 30 42,5 37,5 1 170 85000 PPB1254470*J 250 160 6,8 28 37 42,5 37,5 1 170 85000 PPB1254680*J 250 160 10 30 45 42,5 37,5 1,2 170 85000 PPB1255100*J 250 160 15 35 50 42 37,5 1,2 170 85000 PPB1255150*J (2) 400 250 0,033 5 11 18 15 0,8 910 728000 PPB1402330*E (2) 400 250 0,047 6 12 18 15 0,8 910 728000 PPB1402470*E (2) 400 250 0,068 7,5 13,5 18 15 0,8 910 728000 PPB1402680*E (2) 400 250 0,1 8,5 14,5 18 15 0,8 910 728000 PPB1403100*E (2) 400 250 0,15 10 16 18 15 0,8 910 728000 PPB1403150*E (2) 400 250 0,15 7 16 26,5 22,5 0,8 520 416000 PPB1403150*G (2) 400 250 0,22 10 18,5 26,5 22,5 0,8 520 416000 PPB1403220*G (2) 400 250 0,33 11 20 26,5 22,5 0,8 520 416000 PPB1403330*G (2) 400 250 0,33 9 17 32 27,5 0,8 400 320000 PPB1403330*H (2) 400 250 0,47 13 22 26,5 22,5 0,8 520 416000 PPB1403470*G (2) 400 250 0,47 13 22 32 27,5 0,8 400 320000 PPB1403470*H (2) 400 250 0,68 15 24,5 32 27,5 0,8 400 320000 PPB1403680*H (2) 400 250 1 18 33 32 27,5 1 400 320000 PPB1404100*H (2) 400 250 1 17 28 42,5 37,5 1 280 224000 PPB1404100*J (2) 400 250 1,5 17 28 42,5 37,5 1 280 224000 PPB1404150*J (2) 400 250 2,2 22 30 42,5 37,5 1 280 224000 PPB1404220*J (2) 400 250 3,3 28 37 42,5 37,5 1 280 224000 PPB1404330*J (1) Change the * symbol with the needed Cap. tol. code: J=5%, K=10%, M=20% and the symbol with S for 5mm or L for 30 mm lead length (2) Not suitable for across the line application (3) Pulse endurance test not applicable 10.2 Ed. 04 Rev. 01 10.2021