Product Information

H3CA-A-314

H3CA-A-314 electronic component of Omron

Datasheet
Timers Macromatic Timer

Manufacturer: Omron
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 416.8376 ea
Line Total: USD 416.84

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 16 May to Mon. 20 May

MOQ : 1
Multiples : 1
1 : USD 345.2605

     
Manufacturer
Product Category
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
3S4YR-SHR0X electronic component of Omron 3S4YR-SHR0X

Manual Insert IC Card Reader - X-type (ISO+CP8) - PCB Mounted - Black.
Stock : 7

V700A80 electronic component of Omron V700A80

RFID Transponder Tools V700-D13P31 MOUNTING BRACKET
Stock : 41

3S4YR-HSR3 electronic component of Omron 3S4YR-HSR3

Magnetic Card Reader
Stock : 47

WF-SM-30 electronic component of Omron WF-SM-30

RFID Transponder Tools SmartMark Impact Res istant Rub
Stock : 0

V680-A81 electronic component of Omron V680-A81

RFID Transponder Tools V680 D8/32K Tag Spacer
Stock : 0

V3A-6 electronic component of Omron V3A-6

LOW COST SWIPE READR 3968820-9
Stock : 3

V680-A60 2M electronic component of Omron V680-A60 2M

RFID Transponder Tools IntFc Cb V680HAM9181
Stock : 0

V700-A40 2M electronic component of Omron V700-A40 2M

RFID Transponder Tools 2M EXTENSION CABLE
Stock : 1

V680-A60 5M electronic component of Omron V680-A60 5M

RFID Transponder Tools IntFc Cb V680HAM9181
Stock : 1

V680-A60 10M electronic component of Omron V680-A60 10M

RFID Transponder Tools IntFc Cb V680HAM9181
Stock : 0

Image Description
PM4S-A2C10H-DC12V electronic component of Panasonic PM4S-A2C10H-DC12V

Timer; 0,05min÷10h; DPDT; 250VAC/5A; 12VDC; socket, on panel; PIN:8
Stock : 7

PM4S-A2C30H-DC24V electronic component of Panasonic PM4S-A2C30H-DC24V

2 Form C Time Delay Relays Relay Output
Stock : 10

PM4S-A2C60M-DC12V electronic component of Panasonic PM4S-A2C60M-DC12V

2 Form C Time Delay Relays Relay Output
Stock : 10

PM4S-A2C60M-DC24V electronic component of Panasonic PM4S-A2C60M-DC24V

2 Form C Time Delay Relays Relay Output
Stock : 6

99772715 electronic component of Crouzet 99772715

Timers CHM48 ELM HOUR METER 100-130 VAC 60HZ
Stock : 69

99772716 electronic component of Crouzet 99772716

Timers 187-264AC, 60HZ ELM HR METER
Stock : 14

PM4S-A2C10H-AC240V electronic component of Panasonic PM4S-A2C10H-AC240V

Timer; 0,05min÷10h; DPDT; 250VAC/5A; 200÷240VAC; socket, on panel
Stock : 10

PM4S-A2C10M-DC12V electronic component of Panasonic PM4S-A2C10M-DC12V

Timer; 0,05s÷10min; DPDT; 250VAC/5A; 12VDC; socket, on panel; PIN:8
Stock : 4

PM4S-A2C10M-DC24V electronic component of Panasonic PM4S-A2C10M-DC24V

Timer; 0,05s÷10min; DPDT; 250VAC/5A; 24VDC; socket, on panel; PIN:8
Stock : 7

PM4S-A2C30H-AC240V electronic component of Panasonic PM4S-A2C30H-AC240V

Timer; 0,15min÷30h; DPDT; 250VAC/5A; 200÷240VAC; socket, on panel
Stock : 10

Solid-state Timer H3CA CSM H3CA DS E 4 4 DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired time can be set digitally within a range from 0.1 seconds to 9,990 hrs. Four external signal inputs. ON/OFF indicator for control output and bar indicator for remaining time. Conforms to UL, CSA, and CE marking. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Operation/resetting Operation mode Terminal Time-limit Instantaneous Mounting system contact contact Surface Flush mounting mounting/ track mounting Time-limit operation/self- 8 operation modes 11-pin round socket SPDT --- H3CA-A H3CA-A resetting/external (selectable) Front screw H3CA-FA --- resetting (see note 2) (see note 3) Time-limit operation/ ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 self-resetting SPDT SPDT H3CA-8H H3CA-8H Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8. 2. The operation/resetting system depends on the selected operation mode. For details, see Timing Chart. 3. The 8 operation modes are as follows: A: ON-delay operation E: Interval operation B: Repeat cycle operation F: One-shot and flicker operation C: Signal ON/OFF-delay operation (1) G: Signal ON/OFF-delay operation (2) D: Signal OFF-delay operation (1) H: Signal OFF-delay operation (2) Accessories (Order Separately) Name/specifications Model Name/specifications Model Flush mounting adapter Y92F-30 Front connecting socket P2CF-08 Y92F-70 P2CF-11 Y92F-71 Front connecting socket P2CF-08-E Front cover Y92A-48B P2CF-11-E Finger protection (see note 1) Y92A-48D Back connecting socket P3G-08 P3GA-11 Back connecting socket PL08 PL11 Solder terminal Terminal block cover Y92A-48G for P3G-08/P3GA-11 (see note 2) Note: 1. Round crimp terminals cannot be used with finger- protection structure sockets. Use forked crimp terminals. 2. A terminal cover (Y92A-48G) can be used with P3GA-11 and P3G-08 for finger protection. Specifications Time Ranges A desired time can be set within a range of 0.1 s to 9,990 hrs by combining the three thumbwheel switch modules for time setting and one module for time unit selection. Time unit 0.1 s 1 s 0.1 min 1 min 0.1 hrs 1 hr 10 hrs Time range 1 to 999 (3 digits) 1H3CA Ratings Item H3CA-A/H3CA-FA H3CA-8 H3CA-8H Rated supply voltage 24 to 240 VAC (50/60 Hz), 100/110/120, 200/220/240 VAC, (50/60 Hz), (See note 2.) 12 to 240 VDC (permissible ripple: 24 VDC, 110 VDC (permissible ripple: 20% max.) (See note 1.) 20% max.) Operating voltage range 90% to 110% of rated supply voltage 85% to 110% of rated supply voltage Power consumption AC: approx. 4 VA AC: approx. 10 VA/1 W AC: approx. 10 VA/1.5 W DC: approx. 2 W DC: approx. 1 W DC: approx. 2 W Control outputs 3 A at 250 VAC, resistive load (cos = 1) Minimum applicable load H3CA-8, H3CA-A and H3CA-FA: 10 mA at 5 VDC (failure level: Preference value) H3CA-8H: 100mA at 5 VDC (failure level: Preference value) Contact materials : Ag-alloy Note: 1. Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC. 2. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. Characteristics Accuracy of 0.3% 0.05 s operating time Influence of voltage Influence of temperature Setting error 0.5% 0.05 s max. Reset time H3CA-A/-FA:0.5 s max. H3CA-8H/-8: 0.1 s max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Impulse withstand A wide AC/DC power supply range, 200/220/240 V specifications voltage Between power terminals: 5 kV, Between current-carrying terminal and exposed non-current-carrying metal parts: 5 kV 100/110/120 VAC, 100/110 VDC specifications Between power terminals: 3 kV, Between current-carrying terminal and exposed non-current-carrying metal parts: 4.5 kV 24 VDC specifications Between power terminals: 1 kV, Between current-carrying terminal and exposed non-current-carrying metal parts: 1.5 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude for 1 h each in three directions Malfunction: 10 to 55 Hz with 0.5-mm double amplitude for 10 min each in three directions 2 Shock resistance Destruction: 980 m/s 2 Malfunction: 98 m/s Ambient temperature Operating: 10C to 55C Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, cos = 1 at 1,800 operations/h) See Lift-test Curve for more details. Approved standards UL508, CSA C22.2 No. 14, LR, NK Conforms to EN61812-1. EMC (EMI) EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 Weight H3CA-A: approx. 110 g H3CA-FA: approx. 190 g 2

Tariff Desc

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.
OM4
OMRON
Omron Automation
Omron Automation & Safety
Omron Automation and Safety
OMRON AUTOMATION CANADA
OMRON ELECTRONIC COM
OMRON ELECTRONIC COMPONENTS
OMRON ELECTRONICS
Omron Electronics In
Omron Electronics Inc-EMC Div
Omron Electronics Inc-IA Div
OMRON INDUSTRIAL
OMRON INDUSTRIAL AUTOMATION
Omron Industrial Products
OMRON OCB
OMRON SAFETY
OMRON STI

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted