CompoBus/S Cat. No. Q103-E1-7 New Products New Products Programmable Slaves SYSMAC CPM2C CPU Units with CompoBus/S Master Functions Waterproof Terminals Sensor Terminals Remote I/O ModulesMaximum Communications Cycle Time of Long-distance Communications Mode With a trunk line length of 500 m and a total branch Only 1 ms line length of 100 m (2-conductor VCTF cable), you (High-speed Communications Mode) can branch in any way required using a special flat Exchanges 256 I/O points of data with a maximum cable or a 4-conductor VCTF cable as long as the of 32 Slaves at a maximum communications cycle total wiring length is 200 m or less. Communicate time of only 1 ms per point. at a cycle time of only 6 ms. Complicated Connects through a single dedicated cable, *The Long-distance Communications Mode is not supported by the SRT1 Series. wiring between thus greatly saving wiring effort. System An Analog Input Terminal with four points the PC and Cabtire or flat cable is selectable. expansion and an Analog Output Terminal with two repeater terminal Cabtire cable is available for multi-drop, T- is time- branch, or multi-branch lines. points are available. block. Flat cable connects to T-branch connectors, thus consuming. ensuring ease of system expansion. Note: Cabtire and flat cables cannot be used together. Dedi- cated cable saves wiring ef- fort without re- peater termi- nal block. Transmission of ON/OFF signals is time- consuming. A cycle T- time of 1 ms branches max. for up to allow easy 32 Slaves, 256 system I/O points. expansion. Easily connects sensors and Slave Units. Table of contents Features 2 Maintenance 4 Programmable Slaves 6 Complicated CompoBus/S Products 8 sensor wiring. Connections to a Wider Range of Slaves Ensured by Upgraded Models 12 CPM2C-S1 0C CPU Units with CompoBus/S Master 14 Large CPM2C-S1 0C-DRT Programmable Slaves 18 SRM1-C01-V2/C02-V2 Master Control Units (S-Controllers) 22 wiring effort C200HW-SRM21-V1 Master Unit 25 required for dis- Distributed CQM1-SRM21-V1 Master Unit 27 C200PC-ISA 3-SRM SYSMAC Boards with CompoBus/S Master 30 tributed devices han- processing of a CPM2C-SRT21 I/O Link Unit 32 dling only a small CPM1A-SRT21 I/O Link Unit 34 small number of number of I/O SRT2-ID/OD(-1) Transistor Remote I/O Terminals 35 SRT2- D16T(-1) Transistor Remote I/O Terminals with 3-tier Terminal Block 42 points. I/O points. SRT2-R Relay-mounted Remote I/O Terminals 45 SRT2- D32ML(-1) Transistor Remote I/O Terminals with Connectors (32 Points) 51 SRT2-VID/VOD(-1) Transistor Remote I/O Terminals with Connectors (8/16 Points) 59 SRT2- D0 CL(-1) Waterproof Terminals 66 Sensor SRT2- D08S Sensor Terminals 72 Amplifiers SRT1- D04S CompoBus/S Sensor Amplifier Terminals 80 SRT2-AD04 Analog Input Terminal 93 snap on to SRT2-DA02 Analog Output Terminal 96 SRT2-ID16P/OD16P Remote I/O Modules 99 connect. FND-X -SRT Position Drivers 102 Peripheral Devices 105 Ordering Information 107 2 3