WWW.PHIHONG.COM 80W Power over Ethernet Midspan High Power Single Port Injector Features Single Source 4-Pair Powering Wide Operating Temperature Range Diagnostic LEDs Broken Wire Detection Gigabit Compatible 1 Year Warranty Full Protection OCP, OVP, OTP Applications Satellite Receiver Security Cameras Wireless Network Access Points Kiosks LCD Displays Computer Workstations Safety Approvals cUL/UL CCC CE SAA C-Tick Korea (PHC) IRAM Mechanical Characteristics Length: 203mm (8in) Height: 63mm (2.5in) Width: 108mm (4.25in) Weight: 1.93Kg (4.5lbs) Output Specifications Load Regulation DC Output Model Voltage Min. Max. Line Load 1 POE80U-560(G)-R +56V 0A 0.72A 54-57V DC Note: Output measured over data and spare pairs for combined 1.43A output. (1) Consult factory for availability Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 2/21/2019 POE80U Characteristics WWW.PHIHONG.COM INPUT: AC Input Voltage Range EMC 85 to 264VAC Complies with FCC Class B Complies with EN55032 Class B AC Input Voltage Rating 100 to 240VAC Isolation Test Primary to Secondary: 4242VDC for 1 Input Frequency minute, 10mA 47 to 63Hz Primary to Field Ground: 2121VDC for 1 minute AC Input Current Output to Field Ground: 2121VDC 2.0A (RMS) maximum for 90VAC 1.2A (RMS) maximum for 240VAC Immunity ESD: EN61000-4-2 Level 3 AC Inrush Current RS: EN61000-4-3 Level 2 50A (RMS) maximum for nominal input EFT: EN61000-4-4 Level 2 Surge: EN61000-4-5 Level 3 OUTPUT: CS: EN61000-4-6 Level 2 Total Output Power Voltage Dips: EN61000-4-11 80W Harmonic: EN61000-3-2 DC Offset Insulation Resistance No data degradation with DC imbalance Primary to secondary: >10M OHM 500VDC 18mA per min. Primary to Field Ground: >10M OHM 500VDC Ripple and Regulation (P-P) 100mV maximum FEATURE: Detection Efficiency 12.5K ohm detection resistor value required 75% (typical) at maximum load, and to turn on full power (4-pairs) 120VAC 60Hz Over Voltage/Current, Short Circuit Hold-up Time Protection 10mS min. 120VAC and maximum load Outputs equipped with short circuit protection and overload protection as per Transient O/P Voltage Protection 802.3af specifications except max average 60V maximum at switch on/off at any point pair current is 0.72A, Peak 1.4A per pair. on the AC line phase The output can be shorted permanently without damage. ENVIRONMENTAL: Temperature Operation -40 to 55C Non-operation -50 to +85C Humidity 5 to 90%