DC Fan 172 51 mm San Ace 172 9E type Round type General Specifications Material Frame: Aluminum, Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black or Blue Yellow Mass 780 g Specifications The models listed below have pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 109E1712K501 2.9 34.8 4100 8.5 300 243.0 0.976 55 -20 to +60 109E1712Y501 2.3 27.6 3800 7.8 276 210.0 0.843 53 109E1712H501 12 10.2 to 13.8 1.2 14.4 3050 6.4 226 137.2 0.551 47 109E1712F501 0.68 10.8 2500 5.1 180 95.0 0.382 42 109E1712M501 0.48 5.76 2000 4.2 148 67.6 0.271 36 109E1724C501 2.3 55.2 4800 9.9 350 308.0 1.237 60 109E1724K501 1.3 31.2 4100 8.5 300 243.0 0.976 55 -20 to +70 109E1724H501 24 20.4 to 27.6 0.58 13.92 3050 6.4 226 137.2 0.551 47 40000/60C 109E1724F501 0.35 8.4 2500 5.1 180 95 0.382 42 109E1724M501 0.2 4.8 2000 4.2 148 67.6 0.271 36 109E1748C501 1.2 57.6 4800 9.9 350 308.0 1.237 60 109E1748K501 0.7 33.6 4100 8.5 300 243.0 0.976 55 -20 to +60 109E1748H501 48 40.8 to 55.2 0.28 13.44 3050 6.4 226 137.2 0.551 47 -20 to +70 109E1748F501 0.19 9.12 2500 5.1 180 95 0.382 42 -20 to +60 109E1748M501 0.11 5.28 2000 4.2 148 67.6 0.271 36 -20 to +70 The following sensor and control options are available for selection. Available for all models. Without sensor Differs according to the model. Refer to the table on p. 561. Lock sensor PWM control Airflow - Static Pressure Characteristics 109E1712K501 With pulse sensor 109E1712Y501 With pulse sensor 109E1712H501 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 (inch H2O) (Pa) (inch H O) (Pa) (inch H2O) (Pa) 300 1.2 300 0.8 200 1.2 13.8 V 250 1.0 250 1.0 13.8 V 13.8 V 0.6 150 12 V 12 V 200 0.8 200 0.8 12 V 10.2 V 10.2 V 0.6 150 0.6 150 0.4 100 10.2 V 0.4 100 0.4 100 0.2 50 0.2 50 0.2 50 0 0 0 0 0 3 3 0 (m /min) 3 (m /min) 2 4 6 8 10 2 4 6 8 10 1 2 3 4 5 6 7 8 (m /min) (CFM) 0 50 100 150 200 250 300 350 (CFM) (CFM) 0 100 200 300 400 0 50 100 150 200 250 300 Airflow Airflow Airflow 216 Static pressure Static pressure Static pressure Airflow - Static Pressure Characteristics 109E1712F501 With pulse sensor 109E1712M501 With pulse sensor 109E1724C501 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) 2 (inch H O) (Pa) (inch H2O) (Pa) 0.6 150 90 1.6 400 0.35 80 1.4 350 13.8 V 0.5 0.30 27.6 V 70 1.2 300 13.8 V 0.25 24 V 0.4 100 12 V 60 1.0 250 12 V 50 0.20 20.4 V 10.2 V 0.3 0.8 200 10.2 V 40 0.15 0.6 150 0.2 50 30 0.10 0.4 100 20 0.1 0.05 0.2 50 10 0 0 0 0 0 0 3 3 3 1 2 3 4 5 6 7 (m /min) (m /min) (m /min) 1 2 3 4 5 6 2 4 6 8 10 12 (CFM) 0 50 100 150 200 250 (CFM) (CFM) 0 50 100 150 200 0 100 200 300 400 Airflow Airflow Airflow 109E1724K501 With pulse sensor 109E1724H501 With pulse sensor 109E1724F501 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 (inch H2O) (Pa) (inch H O) (Pa) (inch H2O) (Pa) 300 1.2 0.8 200 0.6 150 27.6 V 27.6 V 250 1.0 27.6 V 0.5 0.6 150 24 V 24 V 200 0.8 0.4 100 24 V 20.4 V 20.4 V 20.4 V 150 0.6 0.4 100 0.3 0.4 100 0.2 50 0.2 50 0.2 50 0.1 0 0 0 0 0 0 3 3 (m /min) (m /min) 3 2 4 6 8 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 (m /min) (CFM) (CFM) 50 100 150 200 250 0 100 200 300 400 0 50 100 150 200 250 300 (CFM) 0 Airflow Airflow Airflow 109E1724M501 With pulse sensor 109E1748C501 With pulse sensor 109E1748K501 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 90 1.2 300 1.6 400 0.35 80 1.4 350 1.0 250 0.30 55.2 V 55.2 V 70 1.2 300 27.6 V 48 V 0.25 48 V 60 0.8 200 1.0 250 24 V 0.20 50 40.8 V 40.8 V 0.8 200 0.6 150 20.4 V 40 0.15 0.6 150 30 0.4 100 0.10 0.4 100 20 0.2 50 0.05 0.2 50 10 0 0 0 0 0 0 3 3 3 (m /min) (m /min) (m /min) 1 2 3 4 5 6 2 4 6 8 10 12 2 4 6 8 10 (CFM) (CFM) (CFM) 0 50 100 150 200 0 100 200 300 400 0 100 200 300 400 Airflow Airflow Airflow 109E1748H501 With pulse sensor 109E1748F501 With pulse sensor 109E1748M501 With pulse sensor Operating voltage range Operating voltage range Operating voltage range 2 (inch H2O) (Pa) (inch H O) (Pa) (inch H2O) (Pa) 200 90 0.8 0.6 150 0.35 80 55.2 V 55.2 V 0.5 0.30 70 0.6 150 48 V 55.2 V 0.25 100 60 0.4 48 V 48 V 40.8 V 0.20 50 40.8 V 0.4 100 0.3 40.8 V 40 0.15 0.2 30 50 0.10 0.2 50 20 0.1 0.05 10 0 0 0 0 0 0 3 3 (m /min) 3 (m /min) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 (m /min) 1 2 3 4 5 6 (CFM) (CFM) 50 100 150 200 250 0 50 100 150 200 250 300 0 0 50 100 150 200 (CFM) Airflow Airflow Airflow 217 Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure Static pressure DC Fan 172 mm DC