DC Fan 60 60 20 mm San Ace 60 9P type General Specifications Material Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1) Expected life See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60C, rated voltage) Motor protection function Locked rotor burnout protection, Reverse polarity protection For details, please refer to p. 547. Dielectric strength 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame) Insulation resistance 10 M or more with a 500 VDC megger (between lead wire conductors and frame) Sound pressure level (SPL) At 1 m away from the air inlet Storage temperature -30 to +70C (Non-condensing) Sensor Lead wire Red Black or Blue Yellow Mass 90 g Specifications The models listed below have ribs and pulse sensors. Rated voltage Operating voltage range Rated current Rated input Rated speed Max. airflow Max. static pressure SPL Operating temperature Expected life Model no. -1 V V A W min m/min CFM Pa inchH O dB (A) C h 109P0612W601 6 to 16 0.13 1.56 4200 0.42 14.8 31.8 0.128 31 109P0612H601 12 0.13 1.56 4200 0.42 14.8 31.8 0.128 31 10.2 to 13.8 109P0612M601 0.09 1.08 3200 0.3 10.6 18.8 0.076 25 60000/60C 109P0624W601 12 to 30 0.07 1.68 4200 0.42 14.8 31.8 0.128 31 -20 to +70 109P0624H601 24 0.07 1.68 4200 0.42 14.8 31.8 0.128 31 20.4 to 27.6 109P0624M601 0.05 1.2 3200 0.3 10.6 18.8 0.076 25 109P0648H601 48 43 to 53 0.07 3.36 5600 0.55 19.4 52.9 0.212 41 40000/60C The following sensor and control options are available for selection. Available for all models. Without sensor Lock sensor Airflow - Static Pressure Characteristics 109P0612W601 With pulse sensor 109P0612H601 With pulse sensor 109P0612M601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 60 0.20 50 0.12 30 0.18 13.8 V 0.20 50 0.10 0.16 40 16 V 13.8 V 12 V 0.14 40 0.08 20 0.15 0.12 30 12 V 12 V 0.10 0.06 30 10.2 V 10.2 V 0.10 0.08 20 0.04 10 20 0.06 6 V 0.05 0.04 10 0.02 10 0.02 0 0 0 0 0 0 3 3 3 0.2 0.4 0.6 (m /min) 0.2 0.4 0.6 (m /min) 0.1 0.2 0.3 0.4 0.5 (m /min) 0 5 10 15 20 (CFM) 0 5 10 15 20 (CFM) 0 5 10 15 (CFM) Airflow Airflow Airflow 68 Static pressure Static pressure Static pressure Airflow - Static Pressure Characteristics 109P0624W601 With pulse sensor 109P0624H601 With pulse sensor 109P0624M601 With pulse sensor Operating voltage range Operating voltage range Operating voltage range (inch H2O) (Pa) (inch H2O) (Pa) (inch H2O) (Pa) 0.20 50 0.12 60 30 0.18 27.6 V 0.20 0.10 50 40 0.16 27.6 V 30 V 24 V 0.14 0.08 20 40 0.15 0.12 30 24 V 24 V 0.10 0.06 30 20.4 V 20.4 V 0.10 0.08 20 0.04 10 20 0.06 12 V 0.05 0.04 10 0.02 10 0.02 0 0 0 0 0 0 3 3 3 0.2 0.4 0.6 (m /min) 0.2 0.4 0.6 (m /min) 0.1 0.2 0.3 0.4 0.5 (m /min) 0 5 10 15 20 (CFM) 0 5 10 15 20 (CFM) 0 5 10 15 (CFM) Airflow Airflow Airflow 109P0648H601 With pulse sensor Operating voltage range 2 (inch H O) (Pa) 70 0.25 60 53 V 0.20 50 48 V 40 0.15 43 V 30 0.10 20 0.05 10 0 0 3 0.2 0.4 0.6(m /min) 0 5 10 15 20 (CFM) Airflow Dimensions (unit: mm) +1 0 60 0 20 -1 500.3 (3) 4-4.30.3 (5) Mounting hole Lead wire AWG24 UL 1007 +50 300 0 (10) Rotating direction Airflow direction 69 +1 Static pressure Static pressure 60 0 500.3 Static pressure Static pressure DC Fan 60 mm sq. DC