CPV Series Phase control modules 120/240 VAC models 0-5 V DC phase control Used with Series 1 random-fire solid-state relays PRODUCT SELECTION Description 10 A 25 A 50 A 75 A 90 A 120 VAC 10CPV120 25CPV120 50CPV120 75CPV120 90CPV120 240 VAC 10CPV240 25CPV240 50CPV240 75CPV240 90CPV240 OUTPUT SPECIFICATIONS (voltage) (1) Description 120 VAC 240 VAC Operating Voltage (47-63Hz) Vrms 90-140 VAC 180-280 VAC Transient Overvoltage Vpk 400 600 Maximum Off-State Leakage Current Rated Voltage mArms 10 10 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (2) 500 500 OUTPUT SPECIFICATIONS (current) (1) Description 10 A 25 A 50 A 75 A 90 A Maximum Load Current (3) Arms 10 25 75 50 90 Minimum Load Current Arms 0.04 0.04 0.04 0.04 0.04 Maximum Surge Current (16.6ms) Apk 120 250 625 1000 1200 Maximum On-State Voltage Drop Rated Current Vpk 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (Rjc) C/W 1.48 1.02 0.31 0.63 0.28 Maximum It for Fusing (8.3 msec) A sec 60 260 4150 1620 6000 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 0.5 0.5 CONTROL MODULE INPUT SPECIFICATIONS (1) Description DC Control Control Voltage Range 0-5 VDC Minimum Turn-Off Voltage 1.0 VDC Typical Supply Current 1.6 mA 5 VDC Nominal Control Input Impedance 1500 Ohm Maximum Turn-On Time msec 0.02 Maximum Turn-Off Time msec 1/2 Cycle CONTROL MODULE OUTPUT SPECIFICATIONS (Terminal 4B - Input to Relay) (1) Description DC Control Maximum Off-State Operating Voltage 36 VDC Maximum Load Current (Sink) 3.0 mA Maximum On-State Voltage 3 mA 0.5 VDC Max. Off State Leakage 10 VDC 1.0 ADC GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, signal to load 4000 Vrms Dielectric Strength, signal to Base 4000 Vrms Ambient Operating Temperature Range -30 to 80C Ambient Storage Temperature Range -40 to 125C Weight (typical) 3.0 oz. (43g) Encapsulation Themally Conductive Epoxy For Contact information visit our web site. 2008 Crydom, Inc. www.crydom.com Specifications subject to change without notice. ObsoleteGENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3 ) Heat sinking required (relay only), see derating curves. AVAILABLE OPTIONS CPV120 Control Module Only (120 Vac Line) CPV240 Control Module Only (240 Vac Line) WIRING DIAGRAM AGENCY APPROVAL Rev. 082709 For Contact information visit our web site. 2008 Crydom, Inc. www.crydom.com Specifications subject to change without notice. Obsolete