CUS1500M Series Specifications Model CUS1500M Input Input Voltage range Vac / Vdc 85 - 265Vac, 120 - 340Vdc (1) Input Frequency Hz 47 - 63 Input Current (110/230VAC) A 16 / 8 Inrush Current at 100/200VAC (Cold Start) A 60 Leakage Current uA <300 Power Factor (10/200VAC) - 0.98 / 0.95 Harmonic Compliance - Meets IEC61000-3-2 Hold Up Time ms 20 typical Efficiency - See model selector Conducted & Radiated EMI - EN55011 / EN55032-B, FCC Class B, VCCI-B Immunity - See immunity section Insulation Class - Class I Safety Agency Certifications - IEC/ES/EN60601-1, IEC/UL/EN60950-1, IEC/UL/EN62368-1, EN62477-1 (OVC III), CE Mark Immunity Test Standard Test Level Criteria ESD EN61000-4-2 3 B - Radiated Susceptibility EN61000-4-3 3 A - Electrical Fast Transient Burst EN61000-4-4 3 B - Surge EN61000-4-5 3 (4) B Level 4 common mode only Conducted Susceptibility EN61000-4-6 3 A - Magnetic fields EN61000-4-8 4 A - ESD 4 A - Radiated Susceptibility IEC60601-1-2 Ed.4 3 A - Electrical Fast Transient Burst 3 A - 0% for 1 cycle A 40% for 10/12 cycles B EN61000-4-11 70% for 25/30 cycles B - Voltage Dips and 0% for 250/300 cycles B - Input Interruptions 0% for 1/2 cycle A - 0% for 1 cycle A - IEC60601-1-2 Ed.4 70% for 25/30 cycles B Customer to consider essential performance of end equipment 0% for 250/300 cycles B - SEMI F47 Line Dip SEMI F47 - - At input voltages > 200Vac 2 CUS1500M Series