TS305-11C55 Thermopile Sensor SPECIFICATIONS Thermopile IR-Sensor For Contactless Temperature Measurement Single Element High Signal Flat Filter Accurate Reference Sensor Thermopiles are mainly used for contactless temperature measurement in many applications. Their function is to transfer the heat radiation emitted from the objects into a voltage output. SENSOR SOLUTIONS /// TS305-11C55 Page 1 09/2015 TS305-11C55 Thermopile Sensor FEATURES High Signal Accurate NTC Reference Sensor 5.5 m Long Wave Pass Filter APPLICATIONS Industrial Pyrometers Climate Control Medical ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min Typical Max Unit Description Storage Temperature T -20 +20 +85 C permanent S Storage Temperature T -20 +20 +100 C non permanent S PERFORMANCE SPECS Parameter Symbol Value Unit Condition Operating Ambient Temperature TAmb -20 to +85 C permanent Operating Ambient Temperature TAmb -20 to +100 C non permanent Package TO-5 2 Absorber Area A mm 0.8 0.8 Thermopile Resistance RTP 70 30 k TAmb = +25C Temperature Coefficient TCRTP -0.06 0.04 %/K TAmb = +25C to +75C of Thermopile Resistance T = +25C, T = +100C, Amb Obj Voltage Response VTP 7.0 2.1 mV DC, totally filled field of view Temperature Coefficient TCVTP -0.45 0.08 %/K TAmb = +25C to +75C of Voltage Response Noise Equivalent Voltage NEV 45 nV/Hz T = +25C Amb Rise Time 63 12 5 ms Ambient Temperature Sensor NTC Ambient Temperature Sensor RNTC 100 5 k TAmb = +25C Resistance Beta Value of NTC -Value 3955 0.3% K TAmb = 0C to +50C 10/2015 SENSOR SOLUTIONS /// TS305-11C55 Page 2