EAGLE SIGNAL brand BRE Reset Timer Electronic Timers Electronic low profile surface mount reset timer... features 11 time ranges FM 5 APPROVED E L T E SPECIFICATIONS DESCRIPTION I C M BRE enclosed construction with front facing dial and knob. The BRE T Time Ranges: E R timer has a heavy duty terminal block, with 9 screw terminals that will R O readily accept 16 gauge wire commonly used in industrial circuit wiring. S T Sym. Maximum Minimum Dial Mark N I I Setting Setting Divisions The case of the BR series timer is injection molded Lexan. This M C .05 Sec. 1/4 Sec. 1 5 Sec. E material is recognized by Underwriters Laboratories for use as the sole R support of current carrying components. Lexan is self-extinguishing, has 3 15 Sec15 Sec. 1 Sec. S a high impact strength, and high dimensional stability. 4 30 Sec3 Sec. 2 Sec. 60 Sec6 Sec. 2 Sec. 5 OPERATION 6 150 Sec. 1.5 Sec. 5 Sec. The NEW BRE series reset timers are micro proces-sor driven. They 7 5 Min. 3 Sec. 15 Sec. provide an accurate adjustable time delay between the actuation of the 6 Sec. 30 Sec. 8 10 Min. control circuit and the operation of the load switches. New standard pilot 9 30 Min. 18 Sec. 2 Min. light is on during timing period. 10 60 Min6 Min. 2 Min. 5 Hr. 3 Min. 15 Min. 11 CR1 Standard Start 12 10 Hr. 6 Min. 30 Min. 1 2 Instantaneous contact 8-9 and 8-3 operates directly with Repeatability: Typical 1/4% of full scale energization of 1 & 2, (CRI), E Reset Time: 1 ms offering different sequences of operation depending on the Voltage/Frequency: 120V (+10, -15%), 50/60 Hz control circuit configuration. 240V (+10, -15%), 50/60 Hz Delayed contacts 6-5 close and Power Consumption: 1.5 W 6-7 and 1-4 open when timer 3 4 8 reaches a timed out condition. Output Rating: 10 amp, 1/4 HP, 120/240 VAC 5 Contacts 6-7 and 1-4 close and 1/2 amp, 125 VDC 9 1/4 amp, 240 VDC 6-5 open when timer is reset. 6 Activation Time: 150 ms 7 Dial Setting Accuracy: 3% of full scale Minimum Setting: 2% of full scale CR1 Reverse Start Operating Temperature: -10 to 140F (-23 to +60C) 1 2 Instantaneous contact 8-9 Laboratory Testing: UL Recognition E61735 FM Approval 21038 operates directly with the energization of 1 & 2 (CRI). E Delayed contacts 6-5 close and 6-7 and 3-4 open when timer reaches a timed out position. 3 Contacts 6-7 and 3-4 close and 6-5 open when timer is reset. 4 8 5 9 6 7 5.42 DANAHER INDUSTRIAL CONTROLSDIMENSIONS Inches (mm) 3/16 (4.8) .170 TYP. 2 5/8 (4.3) (66.7) 9/16 3/4 3/4 9/16 1 1/4 (14.3) (19) (31.8) 3 21/32 (92) 3 9/32 (84.1) 4 1/4 (108) SECONDS 5 T E OL T E T 1/8 I 39/64 C 1 3/8 1 49/64 3 2 2 A 1 1 3 9 9 (3.2) M (15.8) T (34.9) (44.8) 3 3/4 L E R 4 4 5 5 6 6 7 7 8 8 (95.3) I R O S ZN I I C N G ORDERING INFORMATION BR E 5 A6 01 FEATURES Sym. Description Sym. Description Surface mounted with dial knob E Blank Standard Timer and 9 point screw type terminal block 01 Reverse Start TIME RANGE Sym. Description Sym. Description 1 5 Sec.* 8 10 Min. VOLTAGE & 3 15 Sec. 9 30 Min. FREQUENCY 4 30 Sec. 10 60 Min. Sym. Description 5 60 Sec. 11 5 Hr. 6 150 Sec. 12 10 Hr. A6 120V, 50/60 Hz B6 7 5 Min. 240V, 50/60 Hz *Not available in B6 version 5.43 DANAHER INDUSTRIAL CONTROLS