175 Watts xppower.com RCL Series 200 W Peak Rating Up to 120 W Convection-cooled IT, Industrial and Medical Safety Approvals Class I & Class II Installations Single, Dual, Triple and Quad Outputs Connector & Mechanical Options 3 Year Warranty Specification Input General Efficiency 80-90% depending on model Input Voltage 85-264 VAC (120-370 VDC) (see note 3) (1) Isolation 4000 VAC Input to Output 2 x MOPP Input Frequency 47-63 Hz 400 Hz (1 x MOPP Class II), Input Current 2.1 A max at 115 VAC 1500 VAC Input to Ground, 1 x MOPP 0.9 A max at 230 VAC 1500 VAC Output to Ground open frame 500 VAC Output to Ground U channel Inrush Current 17 A max at 115 VAC, 35 A max at & covered 230 VAC, cold start at +25 C Switching Frequency PFC 75 kHz typical, PWM 60 kHz typical Power Factor >0.9 Signals Power fail - open collector output Earth Leakage Current 120 A max at 115 VAC / 50 Hz referenced to 0 V sense 200 A max at 230 VAC / 50 Hz Remote Sense See application notes Input Protection Internal T3.15 A/250 V in line and neutral Remote On/Off See application notes MTBF 385 kHrs typical to MIL-HDBK-217F Output at 25 C, GB 3 Power Density 7.1 W/in Output Voltage See models and ratings table and note 2 Output Voltage Trim 10% output 1, outputs 2-4 track by same Environmental percentage Initial Set Accuracy 1% of nominal at 50% load Operating Temperature -10 C to +50 C at full power, derate to 50% power at +70 C Minimum Load See models & ratings table Operating Humidity 5-95% RH, non-condensing Start Up Delay 2 s max Storage Temperature -20 C to +85 C Start Up Rise Time 100 ms max Operating Altitude 3000 m Hold Up Time 20 ms min at nominal low line & max power Shock 30 g peak, half sine, 6 axes Drift <0.2% after 20 mins warm up Vibration 2 g rms, 5-500 Hz, 3 axes Line Regulation 0.5% of nominal over full input range Load Regulation PQ42 & 43: V1 & V2 3%, V3 & V4 5% of EMC & Safety nominal, all other models: V1 1%, V2, V3 & V4 5% of nominal Emissions EN55011/22 class B conducted, class A radiated Transient Response 4% max deviation, recovery to within 1% Harmonic Currents EN61000-3-2 class A in 500 s for a 25% load change at 1 A/s EN61000-3-2 class C for loads 20% Ripple & Noise 50 mV (Vo 5 V), 120 mV (Vo = 12, 15 V), Voltage Flicker EN61000-3-3 200 mV (Vo = 24, 48 V). Measured pk-pk ESD Immunity EN61000-4-2, level 3 Perf Criteria A with a 20 MHz bandwidth Radiated Immunity EN61000-4-3, 10 V rms 80% mod, Overvoltage Protection 115-140% on V1 only, Perf Criteria A recycle input to reset EFT/Burst EN61000-4-4, level 3 Perf Criteria A Overtemperature Fitted with auto restart Surge EN61000-4-5, installation class 3 Protection Perf Criteria A Overload Protection 110-125% - Primary side power limiting Conducted Immunity EN61000-4-6, level 3 Perf Criteria A with auto recovery. Constant current limit Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms, for single output models and foldback 100% 5000 ms, Perf Criteria A, B, B EN60601-1-2, 30% 500 ms, 60% 100 ms, current limit for multi output models. 100% 10 ms, 100% 5000 ms, V3 & V4 PTC resetting fuses Perf Criteria A, A, A, B - 230 VAC Temperature 0.02%/C Contact sales for 115 V operation Coefficient Safety Approvals EN60601-1, ANSI/AAMI ES60601-1, CSA22.2 No.60601-1 per cUL, Including Notes Risk Management, UL60950, EN60950, 1. Safety approvals cover frequency 47-63 Hz. IEC62368, UL62368, EN62368 AC-DCAC-DC RCL175 Models and Ratings (5,6) (6,8) (6,8) Total Power Output 1 Output 2 Output 3 Output 4 Model Number (7) (1) (4,5) (4,5) (1) (1) Max Peak Conv. V Min Max Peak V Min Max Peak V Min Max V Min Max 175 W 204 W 120 W 12.0 V 0.0 A 14.5 A 17.0 A RCL175PS12 175 W 195 W 120 W 15.0 V 0.0 A 11.6 A 13.0 A RCL175PS15 175 W 200 W 120 W 24.0 V 0.0 A 7.2 A 8.3 A RCL175PS24 175 W 200 W 120 W 28.0 V 0.0 A 6.2 A 7.1 A RCL175PS28 175 W 202 W 120 W 48.0 V 0.0 A 3.6 A 4.2 A RCL175PS48 175 W 200 W 110 W +5.0 V 1.5 A 15.0 A - +12.0 V 0.1 A 8.3 A 10.4 A RCL175PD22 175 W 200 W 110 W +5.0 V 1.5 A 15.0 A - +12.0 V 0.1 A 6.3 A 8.4 A F 12 V 0.1 A 2.0 A RCL175PT31 175 W 200 W 110 W +5.0 V 1.5 A 15.0 A - +15.0 V 0.1 A 4.6 A 6.6 A F 15 V 0.1 A 2.0 A RCL175PT32 175 W 200 W 90 W +5.0 V 1.5 A 15.0 A - +12.0 V 0.1 A 5.5 A 7.6 A F 5 V 0.1 A 2.0 A F 12 V 0.1 A 2.0 A RCL175PQ44 175 W 200 W 90 W +5.0 V 1.5 A 15.0 A - +15.0 V 0.1 A 4.0 A 6.0 A F 5 V 0.1 A 2.0 A F 15 V 0.1 A 2.0 A RCL175PQ45 175 W 200 W 90 W +5.0 V 1.5 A 15.0 A - +24.0 V 0.1 A 3.2 A 5.0 A F 12 V 0.1 A 2.0 A F 12 V 0.1 A 2.0 A RCL175PQ46 175 W 200 W 90 W +5.0 V 1.5 A 15.0 A - +24.0 V 0.1 A 3.0 A 5.0 A F 15 V 0.1 A 2.0 A F 15 V 0.1 A 2.0 A RCL175PQ47 Notes 1. Peak rating can be taken for 5 seconds in every minute. Average power not 6. A minimum load of 100 mA is required on output 2, 3 and 4 to maintain the to exceed maximum power. regulation figures. 2. User-accessible fan supply rated at 12 V at 350 mA 7. 12 CFM airflow required for maximum power. (not available on fan-cooled units). 8. Outputs 3 & 4 are floating, they can be connected externally for positive or 3. For operation at 85 VAC output power is derated to 95%. negative output. 4. Output 1 10 A max convection-cooled. 9. Connector kits and cable harnesses available. Consult sales for options. 5. 20 A max from output 1 and 2 combined convection-cooled. Pin Connectors Application Notes INPUT CONNECTOR - P1 Remote Sense - V1 only, compensates for 0.5 V or 10% whichever is lower. Pin Function Power Fail - Open collector output referenced to 0 V sense (when using the 1 Live power fail signal, -Sense must be connected to 0 V). 2 N/C 3 Neutral Remote On/Off - Connect pin 1 (P3) to 0 V to disable unit (optional remote P1 is a 3-way 0.156 pitch square pin header enable specify suffix -E with the model number). Molex housing 09-91-0300 pins 08-50-0106 Applying a logic 0 will also disable the unit. (24-18 AWG) 08-50-0108 (28-22 AWG) OUTPUT CONNECTOR - P2 Options Molex P/No. 26-60-4060 - Single Ouput For U-channel version, add suffix -U to the model number. Molex P/No. 26-60-4120 - Dual Ouput Molex P/No. 26-60-4140 - Triple Output +PD22 For U-channel version with cover kit, add suffix -C to the model number. Molex P/No. 26-60-4160 - Quad Ouput For U-channel version with fan cover kit, add suffix -F to the model number. Pin Function For screw terminals (output connector P2 only). Contact Sales. 1 +Output 1 2 +Output 1 For versions with remote enable. Contact Sales. 3 +Output 1 For foldback current limit on single output models, contact sales. 4 0 V 5 0 V For constant current limit (output 1 & 2) on multi-output models, contact sales. 6 0 V 7 0 V 8 0 V 9 0 V Connector Information 10 +Output 2 11 +Output 2 For all formats, output connector P2 mating halves: 12 +Output 2 13 -Output 3 Single Output Models: 14 +Output 3 Molex housing 09-50-3061 or equivalent 15 -Output 4 Pins 08-50-0106 (24-18 AWG) 08-50-0108 (28-22 AWG) 16 +Output 4 Dual Output Models: SIGNALS CONNECTOR - P3 Molex housing 09-50-3221 or equivalent (except model PD22 which has a 14-way connector) Pin Function Pins 08-50-0106 (24-18 AWG) 08-50-0108 (28-22 AWG) 1 Remote On/Off Triple Output Models: 2 +Sense Molex housing 09-50-3141 or equivalent 3 -Sense Pins 08-50-0106 (24-18 AWG) 08-50-0108 (28-22 AWG) 4 PF signal 5 0 V fan supply Quad Output Models: 6 +12 V fan supply Molex housing 09-50-3161 or equivalent P3 is a 6-way 0.1 pitch square pin header Pins 08-50-0106 (24-18 AWG) 08-50-0108 (28-22 AWG) Molex housing 22-01-2065 pins 08-50-0032 (30-22 AWG) For mating connectors, use pinouts as detailed in this datasheet. May not match manufacturers mold marks on connector.