Temperature Rise Rated Load Through-hole resisT ors Axial l ead Type Cement r esistors Normal style sQP series Non-inductive style NsP series FeATures Power Rating 1W, 2W, 3W, 5W, 7W, 10W, 15W, 20W, 25W, 30W, 40W Resistance Tolerance Wirewound:1%, 5%, Film:5% T.C.R. Wirewound:100ppm/C, 300ppm/C 300ppm/C , Film: DerATiNg Cur Ve TeMPerATure rise 300 iNTroDuCTioN 25 40 70 155 275 C 40W 100 15W 15W-40W 250 10W The materials used and the construction 3W-5W 80 7W 7W-10W 200 5W techniques ensure excellent flame resistance, 1W-2W 60 150 3W arc resistance and moisture resistance as well (%) 40 100 2W as self-extinguishing capabilities. They will (C) 20 50 1W withstand the most rigorous loading test. 0 -50 0 50 100 150 200 250 300 As resistors in radio and television receivers, 20 40 60 80 100 120 hazardous conditions such as smoking and Ambient Temperature (C) Rated Load (%) redheat can be completely prevented by the proper choice of power resistors. DiMeNsioNs Unit: mm sTYle DiMeNsioN Normal Non-inductive l W h d SQP100 NSP100 131.0 5.51.0 5.51.0 0.60.05 SQP200 NSP200 181.0 7.01.0 7.01.0 0.650.05 SQP300 NSP300 221.5 8.01.0 8.01.0 0.80.05 323 L 323 W SQP5WS - 251.5 6.01.0 6.01.0 0.650.05 d H SQP500 NSP500 221.5 9.51.0 9.01.0 0.80.05 SQP700 NSP700 351.5 9.51.0 9.01.0 0.80.05 SQP10A NSP10A 481.5 9.51.0 9.01.0 0.80.05 SQP15A NSP15A 481.5 12.51.0 12.51.0 0.80.05 C L SQP20A NSP20A 605.0 12.51.0 12.51.0 0.80.05 C W SQP25A NSP25A 605.0 14.01.5 13.01.5 0.80.05 +2.5 B 9 9 SQP30A NSP30A 775.0 18.01.5 0.80.05 17.0 -1.0 d E E sQP40A, NsP40A sTYle DiMeNsioN Normal Non-ind. l W h h B C e d SQP40A NSP40A 905.0 19.01.5 20.51.5 19.51.5 15.01.0 323 9.00.5 0.80.05 h H55 eleCTriCAl ChArACTerisTiCs Nor MAl sTYle sTYle sQP100 sQP200 sQP300 sQP5Ws sQP500 sQP700 sQP10A sQP15A sQP20A sQP25A sQP30A sQP40A Power Rating at 25C 15W 20W 25W 30W 40W Power Rating at 40C 3W 5W 7W 10W Power Rating at 70C 1W 2W Maximum Working Voltage 200V 250V 350V 500V 1,000V Maximum Overload Voltage 500V 500V 700V 1,000V 2,000V Voltage Proof on Insulation 500V 500V 700V 1,000V 2,000V Resistance Range (Wirewound) 0.1 - 27 0.03 - 36 0.015 - 68 0.015 - 130 0.05 - 330 0.08 - 510 0.1 - 680 0.15 - 1K - - Resistance Range (Film) 30 - 47K 39 - 1M 75 - 1M 150 - 1M 360 - 100k 560 -100K Operating Temp. Range -55C to +155C Temperature Coefficient Wirewound:100ppm/C, 300ppm/C, Film:300ppm/C No N-iNDu CTiVe sTYle sTYle NsP100 NsP200 NsP300 NsP500 NsP700 NsP10A NsP15A NsP20A NsP25A NsP30A NsP40A Power Rating at 25C 15W 20W 25W 30W 40W Power Rating at 40C 3W 5W 7W 10W Power Rating at 70C 1W 2W Maximum Working Voltage PxR PxR Voltage Proof on Insulation 500V 500V 700V 1,000V 2,000V Resistance Range (Wirewound) 0.08 - 10 0.08 - 10 0.1 - 30 0.1 - 40 0.15 - 65 0.25 - 100 0.25 - 120 0.36 - 160 Operating Temp. Range -55C to +155C Temperature Coefficient 300ppm/C Note: Special value is available on request eNViroNMeNTAl ChArACTerisTiCs Per For MANCe TesT TesT MeTho D APPr Aise Shor t Time Overload IEC 60115-1 4.13 2.5 times RCWV for 5 sec. (Not more than maximum Overload Voltage) 2.0%+0.05 Voltage Proof on Insulation IEC 60115-1 4.7 In V-Block for 60 sec., test voltage as above table No Breakdown Temperature Coefficient IEC 60115-1 4.8 Between -40C to +155C By type Insulation Resistance IEC 60115-1 4.6 in V-block for 60 Sec. >1,000M Solderability IEC 60115-1 4.17 2455C for 30.5 Sec. 95% Min. coverage No deterioration of Solvent Resistance of Marking IEC 60115-1 4.30 IPA for 50.5 Min. with ultrasonic coatings and markings Robustness of Terminations IEC 60115-1 4.16 Direct load for 10 Sec. in the direction of the terminal leads 2.5kg (24.5N) Periodic-pulse Overload IEC 60115-1 4.39 4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off) 2.0%+0.05 Damp Heat Steady State IEC 60115-1 4.24 402C, 90-95% RH for 56 days, loaded with 0.1 times RCWV 5.0%+0.05 Endurance at 70C IEC 60115-1 4.25 702C at RCWV (or Umax., Whichever less) for 1,000 Hr. (1.5Hr.on, 0.5Hr. Off) 5.0%+0.05 Temperature Cycling IEC 60115-1 4.19 -55C Room Temp. +155C Room Temp. (5 cycles) 2.0%+0.05 Resistance to Soldering Heat IEC 60115-1 4.18 2603C for 101 Sec., immersed to a point 30.5mm from the body 1.0%+0.05 Revision: 2020 Note: Rated Continuous Working Voltage (RCWV) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.