Product Information

CT-FRGP300

Product Image X-ON

Datasheet
FLUX REMOVER, AEROSOL, 390ML
Manufacturer: Chemtools



Price (USD)

1: USD 15.2303 ea
Line Total: USD 15.2303

49 - Global Stock
Ships to you between
Fri. 07 Apr to Thu. 13 Apr
MOQ: 1 Multiples:1
Pack Size :   1
Availability Price Quantity
38 - Global Stock


Ships to you between Fri. 07 Apr to Thu. 13 Apr

MOQ : 1
Multiples : 1

Stock Image

CT-FRGP300
Chemtools

1 : USD 15.2303
5 : USD 13.4507
10 : USD 12.5457

     
Manufacturer
Chemtools
Product Category
Unclassified
Cleaner Type
Flux Remover
Cleaner Applications
Contacts, Electromechanical Parts, Electronics, Pcbs
Dispensing Method
Aerosol
Weight
300G
Product Range
-
Volume
-
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image CT-FRHD1L
FLUX REMOVER, HEAVY DUTY, TIN, 1L
Stock : 0
Stock Image CT-ISO20L
ISOPROPANOL, IPA, BOTTLE, 20L
Stock : 0
Stock Image CT-PCBW20L
CLEAN SOLUTION, PCB WASH, BOTTLE, 20L
Stock : 0
Stock Image CT-FRHD300
FLUX REMOVER, HEAVY DUTY, AEROSOL, 390ML
Stock : 36
Stock Image CT-ISO1L
ISOPROPANOL ALCOHOL, 1L
Stock : 0
Stock Image CT-ISO5L
ISOPROPANOL ALCOHOL, 5L
Stock : 0
Stock Image CT-LQR1L
PCB LACQUER, CLEAR, TIN, 1L
Stock : 0
Stock Image CT-LQR400
PCB LACQUER, CLEAR, AEROSOL, 400G
Stock : 0
Stock Image CT-NC-DP
FLUX DISPENSING PEN, NO CLEAN
Stock : 58
Stock Image CT-PCBW5L
PCB WASH,WATER BASED, 5L
Stock : 0
Image Description
Stock Image CT-FRHD300

FLUX REMOVER, HEAVY DUTY, AEROSOL, 390ML
Stock : 36

Stock Image CTG

CONTACT TREATMENT GREASE, SYRINGE, 35ML
Stock : 0

Stock Image WR21-L12A-GE1-TA

TRANSPORT WR21 - LTE EMEA (800
Stock : 0

Stock Image 233-210

2 Solder Pin / Pole 10 Pole 2.5 mm Pitch PCB Terminal Strip
Stock : 0

Stock Image PRF90

ebm-papst
Stock : 113

Stock Image 1203034A00E007

CONNECTOR: COAXIAL Coaxial connector < 1 000 V
Stock : 0

Stock Image 1203034A00E002

CONNECTOR: COAXIAL Coaxial connector < 1 000 V
Stock : 0

Stock Image 233-208

TERMINAL BLOCK, WIRE TO BRD, 8POS, 20AWG
Stock : 260

Stock Image WR 2000D (UK + EU)

DESOLDERING STATION, WR 2000D, UK+EU
Stock : 0

Stock Image WR 2000A (UK + EU)

HOT AIR STATION, 50°C - 550°C,230V,UK/EU
Stock : 0

Kleanium GP Aerosol 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: Chemtools Kleanium GP Flux Remover Aerosol Product Type: Flux solvent for industrial use. Part Numbers: CT-FRGP-300 Company Address: Chemtools Pty,. Ltd., PO Box 463, Emu Plains, NSW 2750 Ph: 1300 738 250 EMERGENCY PHONE: Australia: Poisons Information Centre 13 1126 International: Infotrac (708) 918 1900 2. COMPOSITION/INFORMATION ON INGREDIENTS Hazardous components CAS % HSIS TWA HSIS STEL 3 3 2-methyl pentane 107-83-5 30 - 60 500ppm 1760mg/m 1000ppm 3,500/m 3 3 propan-2-ol 67-63-0 10 - 30 400ppm 983mg/m 500ppm 1,230mg/m 3 3 propylene glycol monomethyl ether 107-98-2 10 - 30 100ppm 369 mg/m 150ppm 553 mg/m 3 3 cyclohexane 110-82-7 <10 100ppm 350 mg/m 300ppm 1050 mg/m 3 n-hexane 110-54-3 <10 20ppm 72mg/m 3 3 carbon dioxide 124-38-9 <10 5,000ppm 9,000mg/m 30,000ppm 54,000mg/m 3. HAZARDS IDENTIFICATION Hazard Classification: Hazardous Material, Dangerous Goods according to the criteria of SafeWork Australia and the ADG-7 code) Risk Phrases: R11 Highly flammable R22 Harmful if swallowed R36/38 Irritating to eyes and skin. R67 Vapours may cause drowsiness and dizziness. R51 - Toxic to aquatic organisms. R52 - Harmful to aquatic organisms. R53 - May cause long-term adverse effects in the aquatic environment. Safety Phrases: S20 When using do not eat or drink S21 When using do not smoke S51 Use only in well ventilated areas. S24/25 Avoid contact with skin and eyes. Relevant routes of exposure: Skin, Inhalation, Eyes Potential Health Effects Inhalation: May cause respiratory tract irritation. High concentrations of vapours may cause headache, fatigue, drowsiness and dizziness. Skin contact: May cause allergic skin reaction. May cause skin irritation. Product has a defatting effect on skin. Prolonged contact may cause dryness of skin. Eye contact: Contact with eyes will cause irritation. Ingestion: Harmful. May cause lung damage if swallowed. 4. FIRST AID MEASURES Inhalation: Remove to fresh air. If symptoms develop and persist, get medical attention. Skin contact: Wash with soap and water. Remove contaminated clothing and shoes. Wash clothing before reuse. Get medical attention if symptoms occur. Eye contact: Check for and remove any contact lenses. Immediately flush with copious amounts of water, preferably, lukewarm water for at least 15 minutes, holding eyelids open all the time. Get medical attention. Ingestion: Do not induce vomiting. Rinse mouth thoroughly. Loosen any tight clothing. Keep individual calm. Obtain medical attention. 5. FIRE-FIGHTING MEASURES Flash point: 0C Cleveland closed cup Autoignition temperature: >200C Flammable/Explosive limits-lower %: 0.7% Flammable/Explosive limits-upper %: 8.3% Extinguishing media: Foam, dry chemical or carbon dioxide. Special fire fighting procedures: None Unusual fire or explosion hazards: None Material Safety Data Sheet info chemtools.com.au Issued by: Chemtools Pty., Ltd., Page 1 of 3 www.chemtools.com.au Kleanium GP Aerosol Hazardous combustion products: Oxides of carbon. Irritating organic vapours. Keep run-off water out of sewers and water sources. Hazchem Code: 2 Y E 6. ACCIDENTAL RELEASE MEASURES Environmental precautions: Extinguish all ignition sources. Ventilate well. Use approved respirator if air contamination is above accepted level. Prevent product from entering drains or open waters. Clean-up methods: Soak up with inert absorbent. Store in a partly filled, closed container until disposal. 7. HANDLING AND STORAGE Handling: Avoid contact with eyes, skin and clothing. Avoid breathing vapour and mist. Wash thoroughly after handling. Storage: For safe storage, store at or below 38C (100F). Keep in a cool, well-ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use. Incompatible products: Refer to Section 10. 8. EXPOSURE CONTROLS / PERSONAL PROTECTION Engineering controls: No specific ventilation requirements noted, but forced ventilation may still be required if concentrations exceed occupational exposure limits. Respiratory protection: Use NIOSH approved respirator if there is potential to exceed exposure limit(s). Skin protection: Use impermeable gloves and protective clothing as necessary to prevent skin contact. Neoprene gloves. butyl rubber gloves. Natural rubber gloves. Eye/face protection: Safety goggles or safety glasses with side shields. See Section 2 for exposure limits. 9. PHYSICAL AND CHEMICAL PROPERTIES Physical state: Liquid in aerosol canister. Colour: Clear, colourless. Odour: Organic solvents. pH: Not available Boiling point/range: >80C. Melting point/range: Not available Specific gravity: 0.78 at 20C. Vapour density: >1 Evaporation rate: Not available Solubility in water: Insoluble. 10. STABILITY AND REACTIVITY Stability: Stable. Hazardous polymerization: Will not occur. Hazardous decomposition products: Oxides of carbon. Incompatibility: Strong oxidizers. Strong reducing agents. Conditions to avoid: SeeHandling and Storag (Section 7) andIncompatibilit (Section 10). 11. TOXICOLOGICAL INFORMATION Product toxicity data: 2-methyl pentane Expected to be of low toxicity: LD >2000mg/kg, Rat. Aspiration into lungs when swallowed 50 or vomited may cause chemical pneumonitis which can be fatal. n-hexane Oral: LD 28,710 mg/Kg (rat). Irritation eye: 10 mg mild (rabbit). Investigated as a 50 tumorigen, mutagen and reproductive effector. Carcinogenic effects: None by IARC Isopropyl alcohol Oral: LD 5,045 mg/Kg (rat). Skin: LD 12.8g/Kg (rabbit) Inhalation LC : 16,000ppm/8hr 50 50 50 (rat) Investigated as a tumorigen, mutagen, and reproductive effector. Carcinogenic effects: IARC Category 3 1-methoxy-2-propanol Oral: LD 5,660 mg/Kg (rat). Skin: LD 13.0g/Kg (rabbit) Inhalation LC : 10,000ppm/5hr 50 50 50 (rat) Investigated as a reproductive effector Carcinogenic effects: None by IARC Cyclohexane Oral: LD >2,000 mg/Kg (rat). Skin: LD >2g/Kg (rat) Inhalation LC : >20mg/L/4hr (rat) 50 50 50 Investigated as a carcinogen. 12. ECOLOGICAL INFORMATION Ecological information: Dangerous to the environment if discharged into watercourses. Material Safety Data Sheet info chemtools.com.au Issued by: Chemtools Pty., Ltd., Page 2 of 3 www.chemtools.com.au