Product Information

19665

19665 electronic component of Desco

Datasheet
Anti-Static Control Products MONITOR DUAL WIRE CONTINUOUS

Manufacturer: Desco
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 351.5032 ea
Line Total: USD 351.5

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

19665
Desco

1 : USD 351.5032

0 - WHS 2


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 10
Multiples : 10

Stock Image

19665
Desco

10 : USD 356.954

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Brand
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1/6PLDES1200 electronic component of Desco 1/6PLDES1200

Desiccant Moisture Absorption 1 (1200 ea 2.125" L x 2.125" W)
Stock : 0

09200 electronic component of Desco 09200

Antistatic Control Products Premium Adjustable Expansion Wrist Strap, Metal, Red-White-Blue
Stock : 1

06742 electronic component of Desco 06742

Labels and Industrial Warning Signs Sign Area Warning 17x22 Pack of 5
Stock : 1

07502 electronic component of Desco 07502

Antistatic Control Products FOOT GRND SOLE MED
Stock : 11

09214 electronic component of Desco 09214

Antistatic Control Products WRIST STRAP, MAGSNAP, ELASTIC ADJ,WHITE, 6' CORD, CLEAN PACK
Stock : 1

1001230 electronic component of Desco 1001230

1000 Series 12 inch x 30 inch 3.1 mils Metal-In ESD Bag
Stock : 0

100630 electronic component of Desco 100630

Static Shielding Bag <10nJ Energy Shielding Silver 6" (152.4mm) X 30" (762mm)
Stock : 19

10439 electronic component of Desco 10439

Chemicals REZTORE SURFACE/MAT CLEANER 16 oz SPRAY
Stock : 1

10566 electronic component of Desco 10566

Antistatic Control Products CLEANER, FLOOR, NEUTRAL, STATGUARD, 5 GAL BOX
Stock : 1

12917 electronic component of Desco 12917

Antistatic Control Products STATIC SHIELD BAG,81705 SERIES METAL-IN, 9x12, 100 EA
Stock : 0

Image Description
14000 electronic component of Desco 14000

DRG CHN GNDNG 1MEG 7MM 24''
Stock : 35

HGS1MD-RED electronic component of Desco HGS1MD-RED

Anti-Static Control Products HEEL GROUNDER STD RED
Stock : 0

24723 electronic component of Desco 24723

Antistatic Control Products HEEL GROUNDER, WESCORP, ECONOMY
Stock : 1

14213 electronic component of Desco 14213

Anti-Static Control Products 10mm STD w/1meg 15ft GROUND CORD KIT
Stock : 74

13440 electronic component of Desco 13440

Antistatic Control Products BAG, STATSHIELD, METAL-IN 6IN x 8IN, 100 EA/PACK
Stock : 3

HGC1M electronic component of Desco HGC1M

Anti-Static Control Products HEEL GROUNDER CUP 1M RESISTOR
Stock : 1

95205 electronic component of Desco 95205

Antistatic Control Products Heel Strap
Stock : 1

STNBSF64 electronic component of PRINTTEC STNBSF64

Conductive foam; ESD; L:600mm; W:400mm; Thk:10mm; black
Stock : 23

STP1110 electronic component of PRINTTEC STP1110

Bin; ESD; L:138mm; W:93mm; H:46mm; black
Stock : 0

VE330BJ09 electronic component of DELTA PLUS VE330BJ09

Protective gloves; Size: 9/10; yellow-blue; latex; DUOCOLOR VE330
Stock : 19

TECHNICAL BULLETIN TB-3019 Dual-Wire Dual-Operator Programmable Monitor Made in the Installation, Operation and Maintenance United States of America Features and Components A B Figure 1. Desco 19665 Dual-Wire Dual-Operator Programmable Monitor C D Description FRONT VIEW The Desco Dual-Wire Dual-Operator Programmable Monitor monitors two operators and two ESD worksurfaces eliminating the need for periodic testing and record keeping of wrist straps. The Dual-Wire Dual-Operator Programmable Monitor uses low-voltage steady state DC continuous-loop technology to continuously monitor (versus pulsed or intermittent) dual-wire wrist strap functionality. Independent audio and visual alarm conditions make it easy to identify the status of the worksurfaces and operators. Two operator remotes with 10 foot cables are included for use at adjacent workstations. Each monitor is calibrated with accepted E F G H I J K L procedures and standards traceable to the National Institute of Standards and Technology (NIST) and includes a NIST BACK VIEW certificate. Figure 2. Dual-Wire Dual-Operator Programmable ANSI/ESD S20.20 section 7.3 states Compliance verification Monitor features and components records shall be established and maintained to provide evidence of conformity to the technical requirements. A. Operator 1 Status LEDs: When the green LED is Per ANSI/ESD S1.1 Annex A.3 Daily (wrist strap system) illuminated, operator 1 is properly grounded. When the LED testing may be omitted if constant monitoring used. Per is illuminated red or yellow and the alarm sounds, operator 1 ESD Handbook ESD TR 20.20 section 5.3.2.4.4 Typical is not properly grounded. Test programs recommend that wrist straps that are used daily should be tested daily. However, if the products that B. Worksurface 1 Status LEDs: When the green LED is are being produced are of such value that knowledge of a illuminated, worksurface 1 is properly grounded. When the continuous, reliable ground is needed, and then continuous red LED is illuminated and the alarm sounds, worksurface 1 monitoring should be considered or even required. is not properly grounded. C. Operator 2 Status LEDs: When the green LED is Packaging illuminated, operator 2 is properly grounded. When the LED 1 Dual-Wire Dual-Operator Programmable Monitor is illuminated red or yellow and the alarm sounds, operator 2 1 Power Adapter, 12VDC, N. America is not properly grounded. 2 Operator Remotes with Attached Cables (1 black, 1 white) D. Worksurface 2 Status LEDs: When the green LED is 2 Mat Monitor Cords (1 black, 1 white) illuminated, worksurface 2 is properly grounded. When the 2 Mat Ground Cords (green and yellow) LED is illuminated red and the alarm sounds, worksurface 2 1 Monitor Ground Cord (green and yellow) is not properly grounded. 1 Universal Snap Kit E. Power Jack: Connect to the included 12VDC power 1 Certificate of Calibration adapter. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website: Desco.com 2017 DESCO INDUSTRIES, INC. TB-3019 Page 1 of 4 October 2017 Employee OwnedF. Operator 2 Remote Jack: Connect to the black operator remote cable. G. Operator 1 Remote Jack: Connect to the white operator remote cable. H. Monitored Mat 1 Terminal: Monitors a worksurface mat for proper dissipative resistance and static charges. Connect OPERATOR 2 the white mat monitor cord here. OPERATOR 2 REMOTE JACK REMOTE JACK WHITE CABLE BLACK CABLE I. Ground Terminal: Common ground point for the monitor. WRIST WRIST STRAP STRAP MONITOR MONITOR Connect to the green and yellow monitor ground cord. MAT 1 WIRING J. Monitored Mat 2 Terminal: Monitors a worksurface mat MAT 2 WIRING ELECTRIC WHITE CABLE BLACK CABLE GROUND for proper dissipative resistance and static charges. Connect Screw allows ground cord to be bolted to mat keeps cord the black monitor cord here. from disconnecting. or or K. Data Output: To be used with the EMIT 50476 Smart 10mm PUSH & 10mm PUSH & Hub and EMIT SIM Software for automated record keeping CLINCH SNAP CLINCH SNAP of the monitors performance. Click here to learn more about the EMIT SIM Software. 10mm snap needs to pierce 10mm snap needs to pierce and clinch bottom side of and clinch bottom side of L. Alarm Audible Adjustment: Turn the trimpot mat. Snap needs to be at mat. Snap needs to be at least 12 apart or 72 max. least 12 apart or 72 max. BENCH counter-clockwise to increase the audible alarm volume and GROUND OPERATOR 2 OPERATOR 1 clockwise to decrease it. WORKSURFACE WORKSURFACE Installation Figure 3. Installing the Dual-Wire Dual-Operator 1. Determine the mounting location of the Dual-Wire Programmable Monitor Dual-Operator Monitor. The front panel should be visible to both operators. Operation 2. Determine the mounting locations of the operator 1. Monitoring of the operators will remain in the STANDBY remotes. Be sure to install the remotes at a distance condition until a wrist cord is plugged into the operator that enables the 10 foot leads to reach the back of the remote. STANDBY mode is indicated by a blinking monitor. yellow operator LED. 3. Install tinned wire ends of the mat cords to their 2. Plug a wrist strap cord, not attached to the wristband, appropriate screw terminal block located at the back of into the monitored jack labeled WRIST STRAP the monitor. MONITOR located on the remote. This automatically activates the selected operator channel. The 4. Attach the worksurface mats to ground using the green corresponding operator LED should illuminate red and mat ground cord. Install the ring terminal end of the the alarm should sound on the monitor. cord to an appropriate ground point. Attach the snaps terminals to the snaps on the worksurface mat. 3. Remove the charges from your body by making contact with a properly grounded ESD worksurface. 5. Install the tinned wire end of the green and yellow moniitor ground cord to the ground terminal located 4. Snap the cord to the wristband, and fit it snugly onto at the back of the monitor. Install its ring terminal to an your wrist. This should silence the audible alarm and appropriate ground point. Be sure to use a different cause the corresponding operator LED to switch from ground point than the one used for the mats. The face red to green. If this does not happen, examine the wrist plate screw of a grounded AC wall outlet may provide a cord for continuity or damage and your wrist band to convenient connection point. ensure that it is securely fit. If you have dry skin, apply an approved dissipative hand lotion such as 6. Route the mat cords from the back of the monitor to Menda Reztore ESD Hand Lotion. the snaps on worksurface mats. The white cord is for worksurface mat 1. The black cord is for worksurface 5. The AUX GND jack located on the operator remote mat 2. is a grounded and unmonitored connection for guests. It must be used with a banana plug wrist cord and 7. Insert the operator remote cables into their appropriate single-wire wristband. jacks located at the back of the monitor. The white cable is for operator 1. The black cable is for operator 2. NOTE: Worksurface must have a conductive layer such as 8. Connect the power adapter to the power jack located Dual Layer Rubber or Dissipative 3-Layer Vinyl or Micastat at the back of the monitor. Plug the power adapter into Dissipative Laminate with conductive buried layers. EMIT a proper AC power outlet. The monitor is now powered. Continuous Monitors are not recommended for use with homogeneous matting. DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 (909) 627-8178 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 (781) 821-8370 Website: Desco.com 2017 DESCO INDUSTRIES, INC. TB-3019 Page 2 of 4 Employee Owned

Tariff Desc

3926.90.90 Other articles of plastics and articles of other materials ---Other
DES
DESCO EUROPE
DESCO INDUSTRIES
Desco Industries Inc.
Desco Tools
Menda
Protektive
Protektive Pak
Protektive Pak (Desco Industries)
SCC
SCS
STATIC CONTROL SOLUTIONS
Vermason
VERMASON LTD

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted